EMC DS-xxB2 Device Power, Cooling, and Weight Information, Device Dimensions, Depth Width

Page 3

Device Power, Cooling, and Weight Information

Device Power, Cooling, and Weight Information

Table 2 lists the power and cooling requirements and weight information for the DS-16B2 and DS32B2 switches.

Table 2

Device Power, Cooling, and Weight Information

 

 

 

 

 

 

 

 

 

Cooling Requirements

 

Device

 

Power Requirements

(Heat Dissipation)

Maximum Weight

 

 

 

 

DS-16B2 switch

Voltage: 100 to 240 V ac, 47 to 63 Hz

368.5 BTU/hr

12.9 kg (28.5 lbs)

 

 

 

 

DS-32B2 switch

Voltage: 100 to 240 V ac, 47 to 63 Hz

1876 BTU/hr

16.2 kg (35.8 lbs)

 

 

 

 

 

Device Dimensions

Table 3 gives the height, depth, and width for the DS-16B2 switch, the

DS-16B2 switch with rails, and the DS-32B2 switch

Table 3

Device Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device

 

 

Height

 

Depth

Width

 

 

 

 

 

 

 

 

DS-16B2 switch

 

4.34 cm

1.71 in

61.00 cm

24.01 in

42.86 cm

16.87 in

 

 

 

 

 

 

 

 

DS-16B2 switch

1.0 U

4.44 cm

1.75 in

61.00 cm

24.01 in

43.18 cm

17.00 in

with rails

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DS-32B2 switch

1.50

6.55 cm

2.58 in

58.56 cm

23.06 in

42.86 cm

16.87 in

 

 

 

 

 

 

 

 

 

EMC Departmental Switch DS-xxB2 Into Third-Party Racks

3

Image 3
Contents EMC Departmental Switch DS-xxB2 Guide for Installation of Switches Into Third-Party RacksDevice Device Model Mounting Kit Model OverviewDevice Device Power, Cooling, and Weight InformationDevice Dimensions Device Power Requirements Heat DissipationFront Rear Device Placement RequirementsUse Switch Mounting Kit DS16B2RKLSComponent Use Screws, Nuts and WashersTools Required Tools Required for InstallationRear Door Removed for Clarity Front Installing the DS-xxB2 RailsDS-xxB2 Short Rear Rails DS-xxB2 Rails InstallationFront Rails Screw Holes DS-xxB2 Rails Assembly Location of Keps Nuts Assembling the RailsSecuring the Keps Nuts Round-Hole ChannelInstalling Rails in Round-Hole Channels Square-Hole Channel Installing Rails in Square-Hole Channels Mounting Bracket Installation Installing the DS-xxB2 SwitchPlacing the Switch Into the Rack/Cabinet Installing the Switch in the Rack/CabinetM3 x 8-mm Pan Head Screw Tightening the Front and Rear Rail Assembly Screws Sales and Customer Service Contacts Where to Get HelpEMC Departmental Switch DS-xxB2 Into Third-Party Racks