Serial Communication, cont’d
The syntax for setting a special function is __ * X? # where __ is the function number and X? is the value. To view a function’s setting, use __#, where __ is the function number. In the following table the values of the X? variable are different for each command/function. These values are given in the rightmost column.
Command/response table for special function SIS commands
Command | ASCII Command | Response |
| values |
X? | ||||
| (host to switcher) | (switcher to host) | and additional descriptions | |
|
|
|
|
|
Delay times
Power on delay | 1 * |
X? | # | WarmUp* | X? | 0 = 0 seconds, |
|
|
|
| 1 = 2 seconds, |
|
|
|
| 2 = 4 seconds, |
|
|
|
| ... in 2 second steps up to |
|
|
|
| 150 = 300 seconds (5 minutes). |
Example: | 1*8# | WarmUp*08 | Example: set a 16 second power on delay |
Example: | 1# | WarmUp*023 | Example: view the power on delay |
|
|
| setting. |
Power off delay | 2 * |
X? | # | CoolDown* | X? | 0 | = 0 seconds, |
|
|
|
| 1 | = 2 seconds, |
|
|
|
| 2 | = 4 seconds,... in 2 second |
steps up to 150 = 300 seconds.
Example: | 2*23# | CoolDown*023 | Example: set a 46 second power off |
delay.
RGB delay | 3 * |
X? | # | RGBDly* | X? | 0 = 0.0 seconds (default), 1 = 0.5 |
|
|
|
| seconds, 2 = 1.0 seconds, |
|
|
|
| ... in ½ second steps up to |
|
|
|
| 10 = 5.0 seconds |
Example: | 3*7# | RGBDly*07 | Example: 3.5 second RGB delay |
Room relays
Room relay 1 mode/timing | 4 * |
X? | # | Rly1Tm* | X? | 0 = toggle mode (press on/off), | |
|
|
|
| 1 | = momentary, 1/8 second long, |
|
|
|
| 2 | = momentary, ¼ second long, |
|
|
|
| 3 | = momentary, 3/8 second long, |
|
|
|
| ... in 1/8 second steps up to | |
|
|
|
| 16 = 2.0 seconds |
Example: | 4*15# |
| Rly1Tm*15 | Example: momentary, 1.875 sec. long | |||
Room relay 2 mode/timing | 5 * |
| # | Rly2Tm* |
| 0 = toggle mode (press on/off), | |
X? | X? | ||||||
|
|
|
|
|
| 1 | = momentary, 1/8 second long, |
|
|
|
|
|
| 2 | = momentary, ¼ second long, |
|
|
|
|
|
| 3 | = momentary, 3/8 second long, |
|
|
|
|
|
| ... in 1/8 second steps up to | |
|
|
|
|
|
| 16 = 2.0 seconds | |
Example: | 5*8# |
| Rly2Tm*08 | Example: momentary, 1.0 sec. long |
Scaler settings
Scaler output sync format | 6 * |
X? | # | SyncOut* | X? | 0 | = RGBHV (default) |
|
|
|
| 1 | = RGBS |
|
|
|
| 2 | = RGsB (sync on green, SOG) |
Example: | 6*1# |
|
| SyncOut*1 | Example: RGBHV sync output | ||||||
Scaler output polarity | 7 * |
|
|
| # | SyncPol* |
| 0 | = | ||
X? | X? | ||||||||||
|
|
|
|
|
|
|
|
|
| 1 | = |
|
|
|
|
|
|
|
|
|
| 2 | = H+/V- |
|
|
|
|
|
|
|
|
|
| 3 | = H+/V+ |
Example: | 7*1# |
|
| SyncPol*1 | Example: | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
Blue screen (blue & sync output only) | 8* |
| # | Blu* |
|
| 0 | = off (default) (RGB & sync output) | |||
X? | X? | ||||||||||
|
|
|
|
|
|
|
|
|
| 1 = on (blue video & sync output only) | |
Example: | 8*1# |
|
| Blu*1 | Example: blue & sync output for setup | ||||||
|
|
|
|
|
|
|
|
|
|
|
|