2.If necessary, enter the appropriate password.
If the password is accepted, the switcher responds with Login User or Login Administrator.
If the password is not accepted, the Password prompt reappears.
Number of connections
A switcher can have up to 200 simultaneous TCP connections, including all HTTP sockets and Telnet connections. When the connection limit is reached, the switcher accepts no new connections until some have been closed. No error message or indication is given that the connection limit has been reached. To maximize the performance of your switcher, keep the number of connections low and close unnecessary open sockets.
Establishing a USB Port Connection
A standard USB cable and the Extron DataViewer utility, version 2.0 or newer, can be used for connection to the XTP CrossPoint matrix switcher Configuration port. The USB cable, available at any local electronics store, should be terminated on one end with a mini USB B male connector.
NOTE: Before you use the USB port for the first time, install the |
USB driver on your computer. The simplest way to do this is to |
install version 8.0 or newer of the XTP System Configuration |
software and then run the Found New Hardware Wizard. |
Host-to-Switcher Instructions
The switcher accepts SIS commands through its serial port, its USB port, or its LAN port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each switcher response to an SIS command ends with a carriage return and a line feed (CR/LF = ]), which signals the end of the response character string. A string is one or more characters.
NOTE: The tables that begin on the next page are a partial list of SIS |
commands. For a complete listing, see the XTP CrossPoint 1600 |
and 3200 Series User Guide. |
Common SIS Command Symbols
The following symbols are used throughout the command and response tables, which start on page 24:
•= Space
] | = Carriage return and line feed |
} | = Carriage return (no line feed) |
= Pipe (can be used interchangeably with the } character) |
E= Escape key (hex 1B)
W = Can be used interchangeably with the E character
Arrangement of Command and Response Tables
The following pages present five command and response tables, each defining a subset of SIS commands and their responses, with examples where appropriate. The following tables are presented:
•• SIS Command and Response Table for Matrix Switcher Commands, starting on the next page — SIS commands to control and monitor the XTP CrossPoint switcher itself
•• SIS Command and Response Table for XTP T HDMI, starting on page 33 — SIS commands to control and monitor the XTP T HDMI transmitter endpoint from the matrix switcher
•• SIS Command and Response Table for XTP R HDMI and
XTP SR HDMI, starting on page 35 — SIS commands to control and monitor the XTP R HDMI and XTP SR HDMI receiver endpoints from the matrix switcher
•• SIS Command and Response Table for XTP T USW 103, starting on page 38 — SIS commands to control and monitor the XTP T USW 103 switcher endpoint from the matrix switcher
•• SIS Command and Response Table for
22 XTP CrossPoint 1600 and 3200 • Remote Control | XTP CrossPoint 1600 and 3200 • Remote Control 23 |