ValidatorTM Running Manual Tests |
5.4.Step by Step Instructions for Performing Manual Tests
1.From the Start Menu, select Manual Tests. Choose Data, Phone or
Warning! Manual Test Results will NOT be saved.
2.Using the appropriate cable assembly and jacks, connect the
Cable Test
1.Select Cable Test to initiate a test sequence. The wiremap, length, SNR, and Skew results will display. (Figure 5.5)
2.The up and down arrow keys adjust the length constant by .1 pF increments if the cable requires a different setting than that displayed at the top of the screen.
3.On the DATA test screen, the Length (F1) soft key can be used to run the length portion of the test sequence only, skipping the Skew and SNR tests.
Wiremap - DATA Untitled1.job
100% |
2005 Aug 25
10:53:01 VALIDATOR
| Remote ID: 1 |
|
| Length Constant: 15 PF/ft. | |||
1 | Results | 1 |
| Length | Skew | SNR | |
|
| A | 34ft | 1.6 | 30.0 | ||
|
| ||||||
2 |
|
| 2 |
| 34ft |
|
|
3 |
|
| 3 | B | 0.0 | 30.0 | |
|
| ||||||
6 |
|
| 6 |
| |||
|
| 33ft | |||||
4 |
|
| 4 | C | 1.9 | 30.0 | |
5 |
|
| 5 |
| |||
|
|
| |||||
7 |
|
| 7 | D | 34ft | 0.0 | 30.0 |
|
| ||||||
8 |
|
| 8 |
| |||
|
|
| |||||
S | S | Up and Down controls Length Constant | |||||
|
|
|
|
LENGTH
Figure 5.5 Manually Testing Cables
69