LOM Serial A port connects directly to an ASCII terminal or a network terminal server (NTS) using a
The
■System controller configured to be on a network
■System controller Ethernet configured for Dynamic Host Configuration Protocol (DHCP)
■No preconfigured system controller Ethernet IP address, gateway, domain name service (DNS) domain, or DNS servers
▼To Connect the Initial Administrative Console
For the initial configuration, connect LOM Serial A port to the serial port on any of the following devices:
■ASCII terminal
■Sun workstation
■Terminal server (or patch panel connected to a terminal server)
Note – If the IP address assigned to the
1.Connect the administrative console to the LOM Serial A port (FIGURE
The LOM Serial A port is a DTE (data terminal equipment) port. An adapter, crossover cable, or null modem cable is required to connect the LOM Serial A port to another DTE port. For LOM Serial A port connector pinouts and adaptor information, see “LOM Serial A and Serial B Ports” on page 59.
2.Turn the
3.Turn the system power switch to the On position.
Refer to the Netra 1290 Server System Administration Guide,
4.Set up the system console.
Refer to the Netra 1290 Server System Administration Guide,
Chapter 1 Unpacking and Installing the Server 35