Model 6511RC User Manual | 5 • Troubleshooting and maintenance |
|
|
Upon successfully importing the file, the Model 6511RC will display Configuration Load Complete, indi- cating that the new operating parameters have been loaded into flash memory.
4.On the Configuration Menu, click the HOME hyperlink, then click the Hard Reset button under Opera- tor Actions.
Note Do not select Record Current Configuration after importing con- figuration parameters.
Completing the installation
This section verifies that the Model 6511RC is fully operational.
1.Verify that the green POWER LED is lit. If the POWER LED is flashing green, refer to Chapter 5, “Trou- bleshooting and maintenance”.
2.Verify that the WAN LED illuminates, indicating that the Model 6511RC is synchronizing with the T1/E1 signal.
3.Verify that after 5 seconds, the WAN LED begins flashing, indicating that the Model 6511RC is satisfied with the quality of the T1/E1 signal.
4.Verify that after 10 seconds, the WAN LED extinguishes, indicating that the Model 6511RC is satisfied with the network signal and that the link is ready for use.
5.Verify that the green Ethernet LED is either flashing (indicating link status is nominal for the front Ether- net port) or on solid (indicating that link status is nominal for at least one of the Ethernet backplane con- nections).
The Model 6511RC is operational.
Maintenance | 99 |