5 • Troubleshooting and maintenance | Model 6511RC User Manual |
|
|
Table 6. LED status indications and recommended actions (Continued)
LED | Location | Color | Status | Meaning |
|
|
|
| There is NO Ethernet frame activity on either of the 10/100/1000 |
|
|
| Off | |
|
|
|
| Ethernet ports. No action recommended |
READY | Front | Blue | On | Indicates module is ready for removal from cPCI chassis. |
| panel |
| Off | Indicates module NOT ready for removal from cPCI chassis. |
|
|
|
| Do not remove card from chassis. |
ALARM | Rear | Yellow | On solid | A minor alarm condition has been detected. |
| blade |
| Flashing | A major alarm condition has been detected. |
|
|
|
|
|
|
|
| Off | The Model 6511RC is operating normally. No action recommended. |
READY | Rear | Blue | On | Card ready for removal from cPCI chassis. |
| blade |
|
|
|
|
| Off | Card not ready for removal from cPCI chassis. | |
|
|
|
| Do not remove card from chassis. |
ON LINE |
|
| On | Reserved for future use |
|
|
| Off | Reserved for future use |
|
|
|
|
|
10/100 | Front | Green | On | Ethernet Link is established |
ENET | Panel |
|
|
|
Integrated |
|
| Off | No Ethernet link is established |
LEDs on RJ- |
|
|
|
|
| Yellow | On | Flashes to indicates Ethernet frame activity on this port | |
45 connec- |
|
|
|
|
|
| Off | Indicates no Ethernet frame activity on this port | |
tor |
|
| ||
|
|
|
| |
|
|
|
|
|
READY |
| Blue | On | Card ready for removal from cPCI chassis. |
|
|
| Off | Card not ready for removal from cPCI chassis. |
|
|
|
|
|
a. This LED provides status indications for the
Matrix Switch test tools
For the purpose of testing and troubleshooting the
•Loopback test modes for the Matrix Switch
•SDH Section Trace and SDH Path Trace functions for the
Loopback test modes for the STM-1 port
The Matrix Switch provides the following diagnostic loopback test modes for the
•SDH facility loop (see section “Facility Loop [sonetFacilityLoop(1)]” on page 87)
•SDH terminal loop (see section “Terminal loop [sonetTerminalLoop(2)]” on page 88)
•H.110 loop (see section “Other Loop [sonetOtherLoop(3)]” on page 90)
The facility and terminal loops are specified by the SDH protocol. The H.110 loop is proprietary to the Fore- Front Matrix Switch, and fulfills the SDH specification for a third
86 | Matrix Switch test tools |