DeviceNet Remote I/O Communication Module RTU-DNET
Attribute | Access | Name | Range | Default |
|
|
| Explanation | ||
ID | rule |
|
|
| ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| 1 |
| Special module and | |
|
|
|
|
|
|
|
| configuration | ||
|
|
|
|
|
|
|
|
| inconsistent | |
|
|
|
|
|
|
| 0 |
| Configuration data valid | |
|
|
|
|
|
| b3 |
|
|
| |
|
|
|
|
|
| 1 |
| Configuration data | ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| invalid | ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 0 |
| Special module | |
|
|
|
|
|
|
|
| identifiable | ||
|
|
|
|
|
| b4 |
|
| ||
|
|
|
|
|
| 1 |
| Special module | ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| unidentifiable | ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| b5~b15 |
|
| Reserved | |
|
|
|
|
|
|
|
| |||
5 | Get/Set | Work mode | 0 ~ 1 | 0 |
| Work mode of special module | ||||
| 0: auto 1: custom | |||||||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||
6 | Get/Set | Number of | 0 ~ 8 | N/A | Number of input data of special | |||||
input data | modules connected | |||||||||
|
|
|
|
| ||||||
7 | Get/Set | Number of | 0 ~ 8 | N/A | Number of output data of special | |||||
output data | module connected | |||||||||
|
|
|
|
| ||||||
8 |
|
|
| Reserved |
|
|
|
| ||
|
|
|
|
|
| |||||
9 | Get | Error code |
| N/A |
| Error code in special module | ||||
|
|
|
|
|
|
|
|
|
| |
10 ~ 19 |
|
|
| Reserved |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
| Start CR for |
|
|
| Start CR for the input data of special | ||||
20 | Get/Set | module 1 | N/A | N/A | ||||||
module 1 |
|
| ||||||||
|
| input data |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
21 | Get/Set | Input data | N/A | N/A | Length of input data of special module | |||||
length for | ||||||||||
1 |
|
|
| |||||||
|
| module 1 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
22 | Get/Set | Start CR for | N/A | N/A | Start CR for the input data of special | |||||
module 2 | ||||||||||
module 2 |
|
| ||||||||
|
| input data |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
23 | Get/Set | Input data | N/A | N/A | Length of input data of special module | |||||
length for | ||||||||||
2 |
|
|
| |||||||
|
| module 2 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
| Start CR for |
|
|
| Start CR for the input data of special | ||||
24 | Get/Set | module 3 | N/A | N/A | ||||||
module 3 |
|
| ||||||||
|
| inptu data |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
25 | Get/Set | Input data | N/A | N/A | Length of input data of special module | |||||
length for | ||||||||||
3 |
|
|
| |||||||
|
| module 3 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
26 | Get/Set | Start CR for | N/A | N/A | Start CR for the input data of special | |||||
module 4 | ||||||||||
module 4 |
|
| ||||||||
|
| input data |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
| Input data |
|
|
| Length of input data of special module | ||||
27 | Get/Set | length for | N/A | N/A | ||||||
4 |
|
|
| |||||||
|
| module 4 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
28 | Get/Set | Start CR for | N/A | N/A | Start CR for the input data of special | |||||
module 5 | ||||||||||
module 5 |
|
| ||||||||
|
| input data |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
29 | Get/Set | Input data | N/A | N/A | Length of input data of special module | |||||
length for | ||||||||||
5 |
|
|
| |||||||
|
| module 5 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
12 |