Alcatel Carrier Internetworking Solutions TQBJ0223 Replacing the lamp unit, Lamp, After, Hours

Page 52

Replacing the lamp unit

WARNING!

When replacing the lamp, allow it to cool for at least one hour before handling it.

The lamp cover gets very hot, and touching it can cause burns.

Make sure that two lamp units are always installed.

Precautions on lamp unit replacement

Remove the power plug and confirm that the surroundings of the lamp unit have cooled off.

Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, explosion might result.

A used lamp unit may burst if it is handled violently.

For disposition of used lamps, request an industrial waste disposal contractor. If you continue to use a lamp after the replacement time, the lamp may break. Phillips screwdriver is necessary when replacing a lamp unit.

Take care not to slip your hand when using a screwdriver.

Note • It is not possible to turn on the power unless two lamp units are installed.

A lamp unit is an optional part. Contact the dealer.

Replacement lamp unit model No.: ET-LAD40 (single bulb), ET-LAD40W (double bulbs)

Other lamps than specified above cannot be used. Be sure to use the specified lamp.

When to replace the Lamp unit

The lamp units are consumable parts. The lamp brightness decreases gradually as the cumulative operating time increases, so periodic replacement is necessary. The replacement guideline is 3 000 hours, although the lamp may become dead (will not light) before 3 000 hours is reached depending on the characteristics of individual lamps and other factors such as the operating conditions and the installation environment. Therefore, it is recommended for the user to keep a spare lamp unit.

The risk of the lamp bursting increases after 3 000 hours of operation, so the lamp unit turns off automatically.

 

 

On-screen indication

Lamp monitor

 

 

 

LAMP

 

 

REPLACE THE LAMP

 

 

 

 

 

 

 

 

 

After

The indication appears for 30

 

seconds or until any control button

 

2 800 hours

 

is pressed.

The lamp monitor lights up red

 

 

 

 

 

After

The indication will not disappear

even in standby mode.

 

3 000 hours

unless a control button is pressed.

 

 

 

 

 

 

52

Image 52
Contents Commercial Use Model No. PT-D4000EImportant Safety Notice Dear Panasonic CustomerFor Your SAFETY, Please Read the Following Text Carefully Important the Moulded Plug U.K. onlyContents Precautions with regard to safety Remove empty batteries from the remote control at once Do not use or handle the batteries improperlyDo not disassemble the lamp unit Always disconnect all cables before moving the projectorAccessories Do not use the old lamp unitDo not place the projector in extremely hot locations Electric shocks can result if this is not donePrecautions on handling Remote control Name and function of partsBottom Front and side of the projector Status LED lightsRear view of the main unit Controls on rear panel Side-mounted connection terminals Effective range of remote control operation Using the remote control unitLoading dry cells Setting projector ID number to remote control Connect to the projector to use with a cableInstallation Installation geometryProjection schemes Unit mmScreen aspect ratio Projection distance by projection lensScreen aspect ratio Calculation formulas for projection distance by lens types Connection Setup precautionsPin assignments on the RGB2 input terminal are as follows Example of connecting with AV products Example of connecting with PCsPowering up the projector Making adjustment and selectionPress the I button. on the main unit or the remote control When operating at the projector, please refer toPowering off the projector Direct power off functionHow to adjust the FOCUS, Zoom and Shift How to adjust the lensHow to remove the projection lens Automatic adjustment Press the Status button on the remote controlStatus function Press the Shutter button againFor RGB signals For DVI signalsFor S-Video/Video/YPBPRsignals On-screen menusMenu items setting Resetting to the factory defaultBasic menu operations Returning to the previousAdjusting the picture Adjusting the position Clock Phase ZoomKeystone Digital Cinema RealityInput Resolution XGA ModeSxga Mode Clamp PositionOPTION1 settings DVI Signal Level DVI EdidFUNC1 OSD PositionOPTION2 settings InstallationProjector ID AltitudeLamp Relay Lamp SelectRS-232C Auto Power OFF PasswordSystem Information Date and TimeSetting the network Connecting the PCSystem requirements Connection exampleUsing Web Browser Control Accessing from the Web browserPassword change Click Change passwordBasic control Detail control Monitor informationError information An error is detected by self- diagnosis Mail set upOn the next Authentication server set up Mail set up page ContinuingChange the authentication method as desired DNS server set up Ping testContents of mail sent Adjust clockNetwork config Network statusUsing the PJLink protocol Supported commandsPJLink security authentication Command Control Description RemarksSetting the security Password ChangeDisplay Setting Control Device SetupUsing the serial terminals Pin assignments and signal namesCommunication conditions Factory setting Examples of connectionControl commands Cable specificationsConnecting to a PC Computer Projector DTE specifications Pin assignments and controlIndication of lamp monitor Cleaning and replacement of air filter Procedure of cleaningClean the air filter Dismantle the air filterWhen to replace the Lamp unit Replacing the lamp unitLamp AfterLamp unit replacement steps Remove the two screws securing the fan unitLamp unit will be hot after it has been used Have a Phillips screwdriver ready ahead of timeCeiling Mount Bracket Safeguards Installation procedurePower does Not turn onNo image Image is blurredSpecifications PT-D4000ELength of power cord Cabinet Outside dimensionsRemote control Power source Replacement lamp unitCompatible Signal List PAL-M/PAL60 PAL/PAL-N/SECAMInstallation dimensions diagram DimensionsUnit mm For business users in the European Union Trademark Acknowledgement