LG Electronics AVS2400 owner manual Managing Calls from the Web Administration Interface

Page 54

54Installation

Managing Calls from the Web Administration Interface

3

Installation

You can place calls from the Directory tab by selecting an entry and clicking Dial. Dialing an entry from the directory invokes the Call Manager. The Call Manager tab includes all call management features that are available to users. When you move the pointer over an interface element, a tool tip appears to assist you with identifying the call management feature associated with that element. Data that appears in the Call Manager refreshes every five seconds.

Upgrading your System Software

To upgrade the software for your system, follow these steps:

1.Access www.lifesize.com/support.

2.Click the Download Software button.

3.Enter your serial number (located on the back of your system and on the System Information page).

4.Click the link for the software version you wish to download.

5.Download it to a local directory on your system.

6.Access the web administration interface for your system. Refer to “Administration from a Web Browser” on page 28.

7.Click the Maintenance tab.

8.Click System Upgrade.

9.If your upgrade requires you to reset the system to the original default settings, select the Reset to Default State check box.

10.Browse for the upgrade file you downloaded in step 5.

11.Click Upgrade.

NOTE

If calls are connected to the system, a dialog appears prompting you to continue or cancel the upgrade. Click Yes, to continue with the upgrade and disconnect the active calls. The upgrade may take several minutes; do not disrupt the upgrade process. During an upgrade, a status screen appears in the display connected to the system. Users cannot cancel the screen, and the system rejects incoming calls.

12.A system upgrade status message appears when the upgrade is complete. Close the status window and close the administrator configuration window.

13.Your system is ready to use. If you selected the Reset to Default State check box in step 9, you must first reconfigure your system.

Troubleshooting Upgrade Failures

If attempts to upgrade software for your system fail, follow these steps:

1.Ensure you have a valid upgrade image.

2.Reboot the system.

3.Attempt the upgrade again.

4.If a second attempt fails, note the error code returned.

5.If problems persist, please contact the authorized service center or where you purchased.

Image 54
Contents Video Conference Monitor Safety Information Regulatory Information FCC PartLamps Contain Mercury, Dispose Properly Disposal of your old applianceEEE Compliance with Directive. for Turkey only Or moisture, does not operate normally, or has been droppedOn Safety On InstallationOn Disposal On CleaningOn Repacking Lifting and moving the VCSContents Mode settings Customizing OSD settingsMenu settings SpecificationsFeatures IntroductionVCS Body Remote control and batteries UnpackingOverview Front of the VCSPower cord Inlet AC in Connects the power plug Rear of the VCSOSD lock / unlock function Remote Control Battery InstallationConnections Attaching the standUsing the Kensington security system optional Disassembling the standAudio Connecting to a PCVideo Hdmi connectionSUB connection Connecting Network Connecting PowerConnecting Headphones Connecting a MicrophoneAdjusting the angle of the Monitor and camera Attaching the back coverInitial settings for VCS Default administrator password is 1 2 3Set the options of the Identification menu and press Set the options of the Network menu and press button Installation Main screen overview Icon Accessing the System Menu User Preferences setup Access User Preferences from which you can do the followingAdministration Using the Remote Control Administrator PreferencesAccessing Administrative Features Administration from a Web BrowserInstallation Configuring Call Preferences Configuring Security Preferences Controlling Remote AdministrationAdmission Control Changing the Administrator Password Setting the User PasswordViewing Recent Configuration Changes Configuring Audio BehaviorsConfiguring Audio Codec Order Adjusting Audio Levels Administrator Preferences AudioTesting Primary Audio Output Selecting the Active MicrophoneSpecifying the Hostname and Domain Name Service DNS Servers Configuring Network UsageSpecifying a Locally Configured IP Address Specifying Network SpeedSpecifying a Vlan Tag Specifying an NTP ServerEnabling IPv6 Addressing Enabling Network Address Translation NAT Restricting Reserved PortsCall Type Number of Required UDP and TCP Ports Configuring Quality of ServiceConfiguring LifeSize Transit Preferences Call Type Number of Required UDP PortsDisabling Access to the Local Directory Populating the Corporate DirectoryReading from an Ldap Server Ldap preferences are not configuredConfiguring Auto Discovery Server and receive data was successfulConfiguring Communications Preferences Enabling TelepresenceReceiving Presentations Configuring Dialing OptionsSpecifying H.323 Settings Virtual Link Data SharingConfiguring SIP Settings Enabling H.460 Support for H.323 CallsConfiguring Appearance Preferences Video Layout PreferencesLocking the Camera Presets Configuring Video BehaviorsConfiguring Display Preferences Controlling the Camera Use by Far End UsersAdjusting the MTU of Video Packets Configuring System SettingsAdjusting Video Encoder Quality Selecting Priority of Quality Metrics for Source VideoNavigate to Administrator Preferences System License Keys Rebooting the System automaticallyManually Setting System Date and Time Identifying the SystemInstalling a License Key Manually Navigate to Preferences System License KeysHours to complete Using Diagnostics Preferences and Tools Restoring Default SettingsUsing Camera Diagnostic Preferences Using Network UtilitiesRebooting the System Do Not Disturb Exclusive Web Administration Features Using Advanced Directory FeaturesSaving and Restoring a System Configuration Copying Screen Text to the Clipboard Downloading Call HistoryUpgrading System Software Managing Calls from the Web Administration Interface Troubleshooting Upgrade FailuresUpgrading your System Software Upgrade Error Codes Near End Video Quality Placing a CallPlacing a Call from the Redial List To place a call from the directory, follow these steps Placing a Call from the DirectoryManually Dialing a Number from the Main Screen Manually Dialing a Video NumberAnswering or Rejecting a Call Manually Dialing a Voice NumberCall Status Using System Do Not DisturbManaging a Call Caller IDManaging PIP Hiding or Showing User Interface ElementsManaging Audio Managing Video LayoutFar End Video Near End Video Screen Layout Far End VideoNear End Video Far End Video Near End Video During aEnding a Call from the Call Manager Viewing Call StatisticsEnding a Call To hang up a call, press OK again to end the callRemoving an Entry from the Redial List Managing the Redial ListLocking and Unlocking Entries in the Redial List Adding a Redial List Entry to the DirectoryCopying an Entry from the Corporate to the Local Directory Managing the DirectoryAdding an Entry to the Local Directory Removing an Entry from the Local DirectoryEditing an Entry in the Local Directory Adding an Entry to the Meetings DirectoryCustomizing OSD settings Menu settingsNavigation button overview Supported Input Description Mode settings Please contact the service center Check the power cable is connected correctlyCheck the main power switch is turned on Check the input voltage is correctYou can not make a call Configure your display againConnected. Check the signal cable and try again Appears on the screenSpecifications Diagnostic logging 280 x720p @ 25 to 30 fps ResolutionDo Not Disturb mode Directory Service H.350Admin and User level password Save, Lock, Remove Redial List featuresBackup and Restore capability Ability to disable HTTP, SSH and Telnet servicesWarranty Card Appendix