Managing M1112
Setting |
| Value |
|
|
|
|
|
|
Speed |
| 9600 |
|
|
|
Parity |
| None |
|
|
|
Data bits |
| 8 |
|
|
|
Stop bits |
| 1 |
|
|
|
Duplex |
| Full |
|
|
|
Flow control |
| None |
|
|
|
Table | Local management console configuration |
Use the
serial adapter
Figure 5-12 Local management cabling
The command line interface can also be accessed through the Ethernet port of M1112 or through the ATM channels of M1112 on top of the telnet protocol. In order to use the CLI through telnet or the ATM channel, the IP function must be switched on and IP address must be given to the corresponding interface.
M1112 can also be managed remotely through a separate ATM virtual channel. This channel is only used for management purposes. In order to use this management channel, it has to be activated first and given an IP address configuration. The management traffic to this interface is not routed to any other interfaces of M1112.
C33907001SE_00 | E Copyright Nokia Networks Oy |