Cables

The numbers below correspond to the cable numbers in the connection drawings on the following pages.

1-channel intercom cable. Sold Separately. Use Telex ME cables, below. Or, build per Figure 7 on page 19. ME-25: 25’ (7.6 m) cable with Male and Female 3-pin XLR connectors.

ME-50: 50’ (15.2 m) cable with Male and Female 3-pin XLR connectors.

ME-100: 100’ (30.4 m) cable with Male and Female 3-pin XLR connectors.

NOTE: When connecting from the MS-2002 to a TW-7W, keep cables as short as possible. Also, heavier gage wire is recommended.

2-channel intercom cable. Sold separately. Use Telex ME/2 cables, below. Or build per Figure 7. ME-25: 25’ (7.6 m) cable with Male and Female 6-pin XLR connectors.

ME-50: 50’ (15.2 m) cable with Male and Female 6-pin XLR connectors.

ME-100: 100’ (30.4 m) cable with Male and Female 6-pin XLR connectors.

Y adapter cable. Sold Separately. Use Telex CA-23-16. Or, build per Figure 7 on page 19.

3 ft. (0.91 m) speaker cable with RCA plugs. One (1) supplied with each SPS-2001, and SPK-2000.

18” (457 mm) EXP IN/OUT cable, stereo miniplug to stereo miniplug. One (1) supplied with each EMS-4001.

18” (457 mm) CHANNEL OUTPUT cable, 15-pin Male D-Sub to 15-pin Male D-Sub. One (1) supplied with each EMS-4001. (Optional component.)

REFERENCE: See EMS-4001 User Manual (P/N 93507713-000) which can be found at http://www.telexaudiocom.com/ manuals.php for connection information.)

Shielded patch cable, 9-pin Male D-Sub to 9-pin Female D-Sub. Customer local purchase. Available at most electronic stores.

NOTE: All pins must be connected straight through: do not use an RS-232 computer cable.

Shielded patch cable, stereo miniplug to stereo miniplug. Customer local purchase. Available at most electronic stores.

Shielded audio cable. Must have male 3-pin XLR connector at one (1) end for connection to the XP-USPG or XP-4PGM program inputs. Pin-out for program inputs is as follows:

Pin 1:

common

Pin 2:

+ program input

Pin 3:

- program input

Shielded audio cable. Must have male 3-pin XLR connector at one(1) end for connection to the XP-USPG PA output. Pin-out for PA output is as follows:

Pin 1:

common

Pin 2:

+ program input

Pin 3:

- program input

18” (457 mm) CHANNEL OUTPUT cable, 15-pin Male D-Sub to 15-pin Female D-Sub. One (1) supplied with each XP-ES4000A. (Optional component.)

REFERENCE: See EMS-4001 User Manual (P/N 93507713000) which can be found at http://www.telexaudiocom.com/ manuals.php for connection information

14

Image 14
Contents Master Station and Power Supply MS-2002See the enclosed warranty card for further details Important Safety Instructions Page Contents Page Introduction DescriptionFeatures MS-2002 Reference ViewInstallation Configuration Pre-checkSwitch # Description Settings Default Program Interrupt DIP Switches Headset Microphone Type Selection DIP SwitchMic Kill Send Enable DIP Switch Incoming Call Beep DIP SwitchesDirect Program Listen Enable / Disable Jumpers Monaural or Binaural Operation DIP SwitchesBalanced Unbalance Switches Settings for JumpersExternal Program Input and PA Output MountingConnections Cables Page MS-2002 Binaural Master Speaker Station Configuration MS-2002 Typical Speaker Station and Belt Pack Connections Page Audiocom Intercom Cables Page Test Tone Operation and SpecificationsPower-Up Check Sidetone Adjustment MS-2002 Bottom ViewTo check and set the VOX level, do the following Voice-Activated Microphone VOX SetupOperation Tap the Mic Kill keyTo call an intercom channel, do the following To mute the microphone during talk, do the followingTo use the public address system, do the following Using Mic KillPublic Address To turn the program inputs on and off, do the followingIncoming Call Beep on / OFF Using Voice-Activated Microphone VOXTo enable incoming call beep, do the following Specifications General Power RequirementsSpeaker Output Output Level Quick Reference Description Action