Telex MS-2002 user manual See the enclosed warranty card for further details

Page 2

PROPRIETARY NOTICE

The product information and design disclosed herein were originated by and are the property of Bosch Security Systems, Inc. Bosch reserves all patent, proprietary design, manufacturing, reproduction, use and sales rights thereto, and to any article disclosed therein, except to the extent rights are expressly granted to others.

COPYRIGHT NOTICE

Copyright 2010 by Bosch Security Systems, Inc. All rights reserved. Reproduction, in whole or in part, without prior written permission from Bosch is prohibited.

WARRANTY NOTICE

See the enclosed warranty card for further details.

CUSTOMER SUPPORT

Technical questions should be directed to:

Customer Service Department

Bosch Security Systems, Inc.

12000 Portland Avenue South

Burnsville, MN 55337 USA

Telephone: 800-392-3497

Fax: 800-323-0498

Factory Service: 800-553-5992 (Lincoln, NE)

RETURN SHIPPING INSTRUCTIONS

Customer Service Department

Bosch Security Systems, Inc. (Lincoln, NE) Telephone: 402-467-5321

Fax: 402-467-3279

Factory Service: 800-553-5992

Please include a note in the box which supplies the company name, address, phone number, a person to contact regarding the repair, the type and quantity of equipment, a description of the problem and the serial number(s).

SHIPPING TO THE MANUFACTURER

All shipments of product should be made via UPS Ground, prepaid (you may request from Factory Service a different shipment method). Any shipment upgrades will be paid by the customer. The equipment should be shipped in the original packing carton. If the original carton is not available, use any suitable container that is rigid and of adequate size. If a substitute container is used, the equipment should be wrapped in paper and surrounded with at least four (4) inches of excelsior or similar shock-absorbing material. All shipments must be sent to the following address and must include the Proof of Purchase for warranty repair. Upon completion of any repair the equipment will be returned via United Parcel Service or specified shipper, collect.

Factory Service Department

Bosch Security Systems, Inc.

8601 East Cornhusker Hwy.

Lincoln, NE 68507 U.S.A.

Attn: Service

This package should include the following:

QTY

 

DESCRIPTION

PART NUMBER

 

 

 

 

90107749000 (US)

1

MS2002 Final Assembly

or

 

 

 

 

 

90107749001 (EU)

1

User Information

38109-668

1

Statement of Conformity

38109-675

1

Warranty

38110-390

1

User Manual

9350-7749-000

1

1/1/4” Face Plate, Right, Black

91607353-003

1

1/1/4” Face Plate, Left, Black

91607353-002

1

Power Cord

25040003-00

1

Int’l Cordsets, Europeon

550024000

model only

 

 

 

2

Rack Mount Bracket

9110-7353-000

 

 

 

 

THE LIGHTNING

 

CAUTION: TO REDUCE THE

THE

FLASH AND

 

RISK OF ELECTRIC SHOCK, DO

EXCLAMATION

ARROWHEAD

 

NOT REMOVE COVER. NO

POINT WITHIN

WITHIN THE

 

USER-SERVICABLE PARTS

THE TRIANGLE

TRIANGLE IS A

 

INSIDE. REFER SERVICING TO

IS A WARNING

WARNING SIGN

 

QUALIFIED SERVICE

 

SIGN ALERTING

ALERTING YOU

 

PERSONNEL.

 

YOU OF

OF “DANGEROUS

 

 

 

IMPORTANT

VOLTAGE” INSIDE

 

 

 

INSTRUCTIONS

THE PRODUCT.

 

 

 

ACCOMPANYIN

 

 

 

 

 

G THE PRODUCT

 

 

 

 

 

SEE MARKING ON BOTTOM/BACK OF PRODUCT

 

 

 

 

 

 

WARNING: APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS.

WARNING: THE MAIN POWER PLUG MUST REMAIN READILY OPERABLE.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, GROUNDING OF THE CENTER PIN OF THIS PLUG MUST BE MAINTAINED.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPRATUS TO RAIN OR MOISTURE.

WARNING: TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY ATTACHED TO THE FLOOR/WALL/RACK IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.

This product is AC only.

Image 2
Contents Master Station and Power Supply MS-2002See the enclosed warranty card for further details Important Safety Instructions Page Contents Page Introduction DescriptionFeatures MS-2002 Reference ViewInstallation Configuration Pre-checkSwitch # Description Settings Default Program Interrupt DIP Switches Headset Microphone Type Selection DIP SwitchMic Kill Send Enable DIP Switch Incoming Call Beep DIP SwitchesDirect Program Listen Enable / Disable Jumpers Monaural or Binaural Operation DIP SwitchesBalanced Unbalance Switches Settings for JumpersExternal Program Input and PA Output MountingConnections Cables Page MS-2002 Binaural Master Speaker Station Configuration MS-2002 Typical Speaker Station and Belt Pack Connections Page Audiocom Intercom Cables Page Test Tone Operation and SpecificationsPower-Up Check Sidetone Adjustment MS-2002 Bottom ViewTo check and set the VOX level, do the following Voice-Activated Microphone VOX SetupOperation Tap the Mic Kill keyTo call an intercom channel, do the following To mute the microphone during talk, do the followingTo use the public address system, do the following Using Mic KillPublic Address To turn the program inputs on and off, do the followingIncoming Call Beep on / OFF Using Voice-Activated Microphone VOXTo enable incoming call beep, do the following Specifications General Power RequirementsSpeaker Output Output Level Quick Reference Description Action