Sharp ER-A242 Function parameters for EJ, S68 @ 00100002 sA, PGM mode operation records type

Page 48

Function parameters for EJ

 

 

 

 

 

 

 

 

 

To set “00000000”

 

 

 

 

 

s

 

68

 

 

@

 

 

 

 

 

 

 

s

 

A

 

 

 

 

 

 

 

 

*ABCDEFGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Item:

 

 

 

Selection:

Entry:

 

A

Always enter 0.

 

(Fixed position)

0

 

 

 

B

Always enter 0.

 

(Fixed position)

0

 

 

 

C

Temporary EJ printing during a transaction

 

Disallow

0

 

 

 

 

 

 

 

 

Allow*

1

 

 

 

D

EJ printing and clearing EJ data when

 

No*

0

 

 

 

 

issuing general Z1 report

 

Yes

1

 

 

 

E

PGM mode operation records type

 

Details*

0

 

 

 

 

 

 

 

 

Header information only

1

 

 

 

F

REG/MGR/VOID modes operation

 

Details*

0

 

 

 

 

records type

 

Total

1

 

 

 

G

Compressing printing for EJ data

 

No (normal size)

0

 

 

 

 

 

 

 

 

Yes (small size)*

1

 

 

 

H

Action when EJ memory area is full

 

Continue

0

 

 

 

 

 

 

 

 

Warning (near full warning)*

1

 

 

 

 

 

 

 

 

Lock (with near full warning)

2

 

 

On the default setting, an asterisk is marked.

Temporary EJ printing during a transaction

• If selecting “yes”, you can print journal data of a current transaction recorded in EJ memory by pressing the

Rkey during the transaction. To realize this function completely, the cash register is programmed to receipt printing and set Receipt ON/OFF function to OFF.

PGM mode operation records type

The header information only is printed during the program reading operation. The header information only is printed for X/Z reports.

(Receipt sample for Header Information only)

Action when EJ memory area is full

By default, when the memory for EJ becomes nearly full, the cash register shows decimal points at the 8th and 9th positions of the display (EJ memory nearly full message), and the cash register keeps storing new data while erasing the oldest data. When “0” is selected, the cash register will no longer show EJ memory nearly full message. When “2” is selected, the cash register shows EJ memory nearly full message and when the memory is totally full, the cash register locks the sales/data entry with a display of the memory full

message “ ”. You will only be able to issue an EJ report.

Key operation example

Print

s68 @

00100002 sA

46

Image 48
Contents Model ER-A242 For Your Records Introduction For Easy Set-up, see Getting StartedNever operate the register with wet hands Register plugs into any standard wall outlet 120V AC ±10%Contents Correction After Finalizing a Transaction Void mode Basic Function Programming For Quick StartParts and Their Functions External View Front view Rear viewMode Switch and Mode Keys Keyboard layoutKey names 11 MMachine state symbols DisplaysDrawer Lock Key Operator display Customer display Pop-up typeGetting Started Be careful with the paper cutter, so as not to cut yourselfInstalling a paper roll When not using the take-up spool using as receipt paper When using the take-up spool using as journal paperDate Time Tax Starting sales entries Things to do before you start sales entries Things you can do for sales entriesThings to do after you close your store Basic Sales Entry Basic Sales Entry Example1500 5000Error Warning Power Save ModeError escape function Clerk assignmentItem Entries Single item entries Department entriesPLU/subdepartment entries Repeat entries Multiplication entriesSplit pricing entries Single item cash sale Sics entry Displaying SubtotalsFinalization of Transaction Cash or check tendering 300 + Cash or check sale that does not require entryCharge credit sale Mixed-tender sale800 50 t 725 515 Ts t Us tTax Calculation Automatic tax Manual tax25 TUp 400 U Tax status shift1345 T 1050 TUOptional Features Discount and premium entries using the discount key140 570 10 % 800 + P5 %575 + 100675 250 f+Applying preset conversion rate Auxiliary Payment Treatment Currency conversionApplying manual conversion rate Received-on Account and Paid-out Entries No sale exchangeAutomatic Sequence Key akey Entries 12345 s 4800 rCorrection 600 328Correction of the Last Entry direct void Subtotal Void 1310 1755 +Procedure for programming Prior to ProgrammingBasic Function Programming Date and Time ProgrammingTax programming using a tax rate TimeTax Programming for Automatic Tax Calculation Function 1430 s12 s Tax table applicable to the add-on taxSample tax table 100 @ 11 @ 111First figure Limitations to the entry of minimum breakpointsQuantity for doughnut tax exempt for Canadian tax system Sample tax table Example 8%Modification of the left tax table 19 @Auxiliary Function Programming Department ProgrammingDepartment status Preset unit price PLU Price Look-Up and Subdepartment Programming00011173 @ 1000125 # Unit price and associated department assignmentPLU/subdepartment selection Miscellaneous Key Programming Rate for %, &10 P 25 % 9275 200 Amount forPercent rate limitation for % Function parameters for %, &Function parameters for 00011006 @00 @ +/- signFunction parameters for C, c and a when using as CA key Entry digit limit for r, Rand t018 @ Using character keys on the keyboard Hijk N01Text Programming Entering character codes with numeric keys on the keyboard231 Alphanumeric character code tableS1 P S2 PDepartment text PLU text item labelList of function texts 46 @ Card sClerk names Logo messagesDavid s Logo print format 6 typesAdvanced Programming SSS sAS1 @ S2 @ Consecutive numbersElectronic Journal EJ Programming EJ memory typePGM mode operation records type Action when EJ memory area is fullFunction parameters for EJ S68 @ 00100002 sAS5 @ Various Function Selection ProgrammingFunction selection for miscellaneous keys 00000100 sAPrint format Receipt print formatFunction selection for tax Printing styleOther programming Compression printingTax calculation system GSTPower save mode Logo message print format10 @ 0060 sA RS-232C interface 35 @ 30 sATraining clerk specification for training mode Thermal printer densityLanguage selection Auto key programming Automatic sequence key Reading Stored ProgramsKey sequence for reading stored program Auto 2 p100 +Sample printouts Programming reportTraining Mode 1000Programming report Printer density programming report Auto key programming reportReading X and Resetting Z of Sales Totals Summary of Reading X and Resetting Z ReportsDaily Sales Totals Full sales report Sample reportClerk reports PLU sales reportHourly report Periodic Consolidation Full sales reportEJ Report Reading and Resetting Printing journal data on the way of a transactionSample print Sample EJ reportIncorrect receipt Cancellation receipt Override Entries250 Operator Maintenance Case of Power FailureCase of Printer Error Paper specification How to set the paper rollReplacing the Batteries Replacing the Paper RollInstalling the paper roll Removing the paper rollInstalling the journal paper roll Cleaning the Printer Print Head / Sensor / Roller Removing a Paper JamRemoving the Till and the Drawer Opening the Drawer by HandBefore Calling for Service Error code tableSpecifications T I C E Sharp Plaza, Mahwah, New Jersey BE-SHARP