TANDBERG D50104-15 user manual Installation, Unpacking

Page 19

Health Care System III

Installation

Installation

Precautions

Never install telephone wiring during a lightning storm.

Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

Never touch uninstalled telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electrical shock from lightning.

Do not use the telephone to report a gas leak in the vicinity of the leak.

The socket outlet shall be installed near to the equipment and shall be easily accessible.

Never do any installation of cables without first unplugging the main HCS III cart power cord.

1TR6 network type is not approved for connection directly to the telecommunications network. This network type is only to be used behind a PABX.

X.21 network type is not approved for connection directly to the telecommunications network. This network type is only to be used together with already approved equipment, and is not meant for direct connections to the telecommunication networks.

V.35/RS-449/RS-366 network type is not approved for connection directly to the telecommunications network. This network type is only to be used together with already approved equipment, and is not intended for direct connection to the telecommunication networks.

Unpacking

The main HCS III cart is delivered in one crate. The optional mobile camera cart is delivered separately, in its own crate. The equipment is unpacked as follows:

1)Remove the steel straps from the crate.

2)Remove the top cover by lifting it up and off the two side panels.

3)Remove the outer side panel by lifting it out from the skid and away from the unit. Remove the inner side panel the same way.

4)Remove the unit’s right side Styrofoam packing by carefully pulling it away from the unit along the entire height.

5)Remove the unit’s left side Styrofoam packing by raising the camera arm by 90 degrees so that it is horizontal. Do not rotate the display because it must be narrow to fit through the opening in the Styrofoam. Carefully pull the Styrofoam away from the unit.

19

Image 19
Contents Health Care System Declaration of Conformity Copyright 2001, Tandberg For the customers in the USA Symbols Location This Symbol IndicatesOn Safety PrecautionsOn Installation On Storage On CleaningOn Repacking On MobilityContents Getting Started Advanced use Rsvp NAT 100 TIP IntroductionAt a Glance The HCS III System Monitor Main HCS III CartCamera MicrophoneCart Keyboard and Mouse customer suppliedNetwork Terminating Units Remote ControlHeadset and Jack Rear Interface PanelMobile Camera Cart optional Height Adjustable Camera ArmIntroduction Health Care System Unpacking InstallationInstallation Health Care System Connecting the SystemHealth Care System Installation To connect a video cassette recorder VCR VCRDual LAN Cable Isdn BRI CablesNET 1 External Network Interface PRI InterfaceMain HCS III Cart Microphone Installing a PCMicrophone 3 MIC Ancillary Equipment Triple-pivot Arm Counterbalance Adjustment Cart AdjustmentsMonitor Suspension Arm Adjustment Background Brightness Control Loudspeaker VolumeOperational Considerations Iris Control and LightingLighting Guidelines for setting up videoconferencing roomsSystem start-up Getting StartedWelcome menu Quick Keys BasicsMain Menu Menu StructureMenu System configurationLAN configuration Isdn configurationMaking a call Making and ending callsType of calls Selecting / setting default quality bandwidthCorrecting keying mistakes Selecting / setting default networkAnswer a call End a callDirectory Delete Entry Add New EntryEdit Entry Add Site Add MultiSite EntryView outgoing video selfview Adjusting volumeDo Not Disturb / Sleep Mode General useMoving / zooming camera Focusing cameraControlling the Main Camera Selecting video sourcesDeactivating SetupVoice Activated Camera Positioning ActivatingFar end camera control Fecc PresetsSelecting presets Storing presetsReceiving a still image Sending/receiving still imagesSending a still image Viewing a still imageAdd Duo Video Duo VideoEnd a Duo Video call MultiSite MCU MultiSite cascading Establishing MultiSite meetings using DirectoryPress ‘Add Site’ to bring up the MultiSite dial menu Adding an extra site dial outAdding an extra site dial Disconnecting sites from a conferencePC SoftPresenter PC PresenterText Chat / Closed Captioning Web-interfaceStreaming Other PC applicationsMain menu Advanced useVideo VGA ResolutionsCall quality AudioAdvanced call quality Presentations Utilities Continuous Presence Welcome MenuMCU status line System Name MCU servicesTerminal Names Quick MenuRequest floor Release floorChair control Mix Mode Audio SettingsAudio Inputs Audio Outputs Level SettingsEcho Control Level Settings OutputsNoise Reduction Room Size Automatic Gain Control AGC SettingsMotion Alert Speaker Tips for improving the echo canceller performanceAlert Tones & Volume Restore Audio DefaultsVideo Settings VGA Out Quality VGA SettingsVideo Name VGA OutAddress VNC SettingsPassword Start using VNCNetwork Configuration Terminal SettingsIsdn Switch Type ISDN-BRI SettingsLine Setup Subaddress Advanced Isdn settingsPRI Switch Type ISDN-PRI SettingsNumber Channel Hunting Below is a list of common ISDN-PRI/T1 switchesAdvanced ISDN-PRI Settings Line SettingsExternal network settings Leased E1/T1 SettingsNetwork clocking Call controlStreaming Source LAN SettingsAddress Port TTL/Router HopsSettings Register Advanced H.323 SettingsIP Type of Service TOS PrefixIP-address IP SettingsNAT Address IP-assignmentRestart Snmp SettingsIncoming telephone calls Call SettingsAccess Code Incoming MCU callsMax Call Length EncryptionNetwork Profiles Dataport Dataport configurationSoftware Options LanguageDataport System info DiagnosticsChannel status Call status Restore defaultsSystem Selftest View current settingsTest subsystem Far End Loop Isdn onlyAppendix Connecting the HCS III to Isdn using Network AdaptersConnecting ConfiguringConfiguration of the system Connecting the system to the Switched 56 networkUsing Telesync TS-256 SW56/ISDN adapter Configuration of Telesync AdapterUsing CSU adapter Connecting the system to PRI/T1Connecting to Adtran T1 ESF CSU ACE Configuration of Adtran T1 ESF CSU ACE Environmental considerations Description of the different files Using the file systemB2 ABC Appendix 6 Access CodeTechnical Description 101 102 Abbreviations Index Symbols105 USA Servicing