TANDBERG D50104-15 user manual Making and ending calls, Making a call

Page 35

Health Care System III

Getting Started

Making and ending calls

 

Making a call

connect To make a call, enter the number or the IP-address of the unit you wish to call using the Dialing keys and press CONNECT.

ISDN call

The system will, by default, try to connect using Quality: Auto (see table overleaf). If the requested quality (bandwidth) cannot be established, the system will establish a connection on as high quality as possible.

The SoftMux ensures high reliability and includes the unique Downspeeding feature. If channels are dropped during a meeting, Downspeeding automatically maintains the connection without interrupting the call in progress. The SoftMux also enables you to dial to other videoconferencing equipment, phones and mobile phones in the same way and provides you with on-screen, real-time feedback on the progress of a call.

LAN call

To make a call via a LAN, enter an IP-address by using a * as the ‘dot’ in the IP-address, e.g. 123*3*0*12 will be interpreted as 123.3.0.12. If a gatekeeper is present, you may place IP-calls using “telephone-style” numbers (an E.164 alias), according to the numbering plan implemented in the gatekeeper. The dialed number will then be translated into an IP-address by the gatekeeper.

Access Code

If the system requires an Access Code, enter the code and press OK to proceed making a call:

Using sub-address / extension address / MCU password

To specify an ISDN sub-address or its LAN equivalent extension address (TCS-4), add a star (*) after the number and then enter the sub-address/extension address.

Example:

12345678*10 ( <number>*<Sub-address/extension address/MCU password>)

When calling to external MCU’s requiring a password (TSC-1), this password can be added after the star (*). If no password is specified, a menu will prompt you to enter the password (after connected to the MCU).

TIP

SUB-ADDRESS IS USED TO ADDRESS DIFFERENT SYSTEMS ON THE SAME ISDN LINE.

TCS-4IS USED TO ADDRESS DIFFERENT SYSTEMS ON A LAN, WHEN DIALING IN VIA A GATEWAY.

35

Image 35
Contents Health Care System Declaration of Conformity Copyright 2001, Tandberg For the customers in the USA Symbols Location This Symbol IndicatesOn Installation PrecautionsOn Safety On Storage On CleaningOn Repacking On MobilityContents Getting Started Advanced use Rsvp NAT 100 TIP IntroductionAt a Glance The HCS III System Monitor Main HCS III CartCamera MicrophoneCart Keyboard and Mouse customer suppliedNetwork Terminating Units Remote ControlHeadset and Jack Rear Interface PanelMobile Camera Cart optional Height Adjustable Camera ArmIntroduction Health Care System Unpacking InstallationInstallation Health Care System Connecting the SystemHealth Care System Installation To connect a video cassette recorder VCR VCRDual LAN Cable Isdn BRI CablesNET 1 External Network Interface PRI InterfaceMicrophone 3 MIC Installing a PCMain HCS III Cart Microphone Ancillary Equipment Monitor Suspension Arm Adjustment Cart AdjustmentsTriple-pivot Arm Counterbalance Adjustment Background Brightness Control Loudspeaker VolumeOperational Considerations Iris Control and LightingLighting Guidelines for setting up videoconferencing roomsWelcome menu Getting StartedSystem start-up Quick Keys BasicsMain Menu Menu StructureMenu System configurationLAN configuration Isdn configurationMaking a call Making and ending callsType of calls Selecting / setting default quality bandwidthCorrecting keying mistakes Selecting / setting default networkAnswer a call End a callDirectory Edit Entry Add New EntryDelete Entry Add Site Add MultiSite EntryView outgoing video selfview Adjusting volumeDo Not Disturb / Sleep Mode General useMoving / zooming camera Focusing cameraControlling the Main Camera Selecting video sourcesDeactivating SetupVoice Activated Camera Positioning ActivatingFar end camera control Fecc PresetsSelecting presets Storing presetsReceiving a still image Sending/receiving still imagesSending a still image Viewing a still imageAdd Duo Video Duo VideoEnd a Duo Video call MultiSite MCU MultiSite cascading Establishing MultiSite meetings using DirectoryPress ‘Add Site’ to bring up the MultiSite dial menu Adding an extra site dial outAdding an extra site dial Disconnecting sites from a conferencePC SoftPresenter PC PresenterText Chat / Closed Captioning Web-interfaceStreaming Other PC applicationsMain menu Advanced useVideo VGA ResolutionsCall quality AudioAdvanced call quality Presentations Utilities MCU status line Welcome MenuContinuous Presence System Name MCU servicesTerminal Names Quick MenuRequest floor Release floorChair control Audio Inputs Audio SettingsMix Mode Audio Outputs Level SettingsNoise Reduction Level Settings OutputsEcho Control Motion Automatic Gain Control AGC SettingsRoom Size Alert Speaker Tips for improving the echo canceller performanceAlert Tones & Volume Restore Audio DefaultsVideo Settings VGA Out Quality VGA SettingsVideo Name VGA OutAddress VNC SettingsPassword Start using VNCNetwork Configuration Terminal SettingsIsdn Switch Type ISDN-BRI SettingsLine Setup Subaddress Advanced Isdn settingsNumber ISDN-PRI SettingsPRI Switch Type Channel Hunting Below is a list of common ISDN-PRI/T1 switchesAdvanced ISDN-PRI Settings Line SettingsExternal network settings Leased E1/T1 SettingsNetwork clocking Call controlStreaming Source LAN SettingsAddress Port TTL/Router HopsSettings Register Advanced H.323 SettingsIP Type of Service TOS PrefixIP-address IP SettingsNAT Address IP-assignmentRestart Snmp SettingsIncoming telephone calls Call SettingsAccess Code Incoming MCU callsNetwork Profiles EncryptionMax Call Length Dataport Dataport configurationDataport LanguageSoftware Options Channel status DiagnosticsSystem info Call status Restore defaultsSystem Selftest View current settingsTest subsystem Far End Loop Isdn onlyAppendix Connecting the HCS III to Isdn using Network AdaptersConnecting ConfiguringConfiguration of the system Connecting the system to the Switched 56 networkUsing Telesync TS-256 SW56/ISDN adapter Configuration of Telesync AdapterConnecting to Adtran T1 ESF CSU ACE Connecting the system to PRI/T1Using CSU adapter Configuration of Adtran T1 ESF CSU ACE Environmental considerations Description of the different files Using the file systemB2 ABC Appendix 6 Access CodeTechnical Description 101 102 Abbreviations Index Symbols105 USA Servicing