TANDBERG D50104-15 user manual Adding an extra site dial out

Page 50

General Use

Health Care System III

Adding an extra site - dial out

First establish a normal point-to-point call. It is recommended to plan the bandwidth usage before making the first call so that you do not run out of bandwidth.

Example: If the system has 512kbps available and you want to connect 3 sites in addition to the host, 128kbps should be selected for the first call. The system will then automatically use 128kbps when connecting the other sites.

When the first site is connected, add a site to the conference using the following procedure:

connect

• Press CONNECT to bring up the following menu:

 

• Press ‘Add Site’ to bring up the MultiSite dial menu.

NOTE IF THE MULTISITE SYSTEM DOES NOT HAVE ENOUGH BANDWIDTH TO ADD ANOTHER SITE, THE SYSTEM WILL AUTOMATICALLY DOWNSPEED TO ALLOW AN ADDITIONAL SITE TO BE ADDED TO THE CONFERENCE. REQUIREMENT: FAR END MUST SUPPORT DOWNSPEED AND MUST HAVE ENOUGH BANDWIDTH.

TIP CONNECT THE SYSTEM WITH THE LOWEST BANDWIDTH FIRST IN ORDER TO OPTIMIZE CONNECTION TIME.

• Enter the number to call.

The Quality will, by default, be the same as used by the first call. To place a telephone call instead of a video call, press ‘Quality’ and select ‘Teleph’ in the Quality menu.

To use another network operator, press ‘Net’ and select operator in the Net menu.

connect

• Press CONNECT

 

TIP

IT IS POSSIBLE TO CONNECT SEVERAL TELEPHONES, E.G. 2 VIDEO SYSTEMS + 3 TELEPHONES (A TOTAL OF 5 SITES).

50

Image 50
Contents Health Care System Declaration of Conformity Copyright 2001, Tandberg Symbols Location This Symbol Indicates For the customers in the USAOn Installation PrecautionsOn Safety On Mobility On CleaningOn Repacking On StorageContents Getting Started Advanced use Rsvp NAT 100 Introduction TIPAt a Glance The HCS III System Microphone Main HCS III CartCamera MonitorKeyboard and Mouse customer supplied CartRear Interface Panel Remote ControlHeadset and Jack Network Terminating UnitsHeight Adjustable Camera Arm Mobile Camera Cart optionalIntroduction Health Care System Installation UnpackingConnecting the System Installation Health Care SystemHealth Care System Installation VCR To connect a video cassette recorder VCRDual PRI Interface Isdn BRI CablesNET 1 External Network Interface LAN CableMicrophone 3 MIC Installing a PCMain HCS III Cart Microphone Ancillary Equipment Monitor Suspension Arm Adjustment Cart AdjustmentsTriple-pivot Arm Counterbalance Adjustment Iris Control and Lighting Brightness Control Loudspeaker VolumeOperational Considerations BackgroundGuidelines for setting up videoconferencing rooms LightingWelcome menu Getting StartedSystem start-up Basics Quick KeysMenu Structure Main MenuSystem configuration MenuIsdn configuration LAN configurationMaking and ending calls Making a callSelecting / setting default quality bandwidth Type of callsEnd a call Selecting / setting default networkAnswer a call Correcting keying mistakesDirectory Edit Entry Add New EntryDelete Entry Add MultiSite Entry Add SiteGeneral use Adjusting volumeDo Not Disturb / Sleep Mode View outgoing video selfviewSelecting video sources Focusing cameraControlling the Main Camera Moving / zooming cameraActivating SetupVoice Activated Camera Positioning DeactivatingStoring presets PresetsSelecting presets Far end camera control FeccViewing a still image Sending/receiving still imagesSending a still image Receiving a still imageDuo Video Add Duo Video End a Duo Video call MultiSite MCU Establishing MultiSite meetings using Directory MultiSite cascadingAdding an extra site dial out Press ‘Add Site’ to bring up the MultiSite dial menuDisconnecting sites from a conference Adding an extra site dialPC Presenter PC SoftPresenterWeb-interface Text Chat / Closed CaptioningOther PC applications StreamingAdvanced use Main menuAudio VGA ResolutionsCall quality VideoAdvanced call quality Presentations Utilities MCU status line Welcome MenuContinuous Presence MCU services System NameRelease floor Quick MenuRequest floor Terminal NamesChair control Audio Inputs Audio SettingsMix Mode Level Settings Audio OutputsNoise Reduction Level Settings OutputsEcho Control Motion Automatic Gain Control AGC SettingsRoom Size Restore Audio Defaults Tips for improving the echo canceller performanceAlert Tones & Volume Alert SpeakerVideo Settings VGA Out VGA SettingsVideo Name VGA Out QualityStart using VNC VNC SettingsPassword AddressTerminal Settings Network ConfigurationISDN-BRI Settings Isdn Switch TypeLine Setup Advanced Isdn settings SubaddressNumber ISDN-PRI SettingsPRI Switch Type Below is a list of common ISDN-PRI/T1 switches Channel HuntingLine Settings Advanced ISDN-PRI SettingsLeased E1/T1 Settings External network settingsCall control Network clockingTTL/Router Hops LAN SettingsAddress Port Streaming SourceSettings Prefix Advanced H.323 SettingsIP Type of Service TOS RegisterIP-assignment IP SettingsNAT Address IP-addressSnmp Settings RestartIncoming MCU calls Call SettingsAccess Code Incoming telephone callsNetwork Profiles EncryptionMax Call Length Dataport configuration DataportDataport LanguageSoftware Options Channel status DiagnosticsSystem info Restore defaults Call statusFar End Loop Isdn only View current settingsTest subsystem System SelftestConfiguring Connecting the HCS III to Isdn using Network AdaptersConnecting AppendixConfiguration of Telesync Adapter Connecting the system to the Switched 56 networkUsing Telesync TS-256 SW56/ISDN adapter Configuration of the systemConnecting to Adtran T1 ESF CSU ACE Connecting the system to PRI/T1Using CSU adapter Configuration of Adtran T1 ESF CSU ACE Environmental considerations Using the file system Description of the different filesAppendix 6 Access Code B2 ABCTechnical Description 101 102 Abbreviations Symbols Index105 Servicing USA