TANDBERG D50104-15 user manual Advanced call quality

Page 57

Health Care System III

Advanced Use

Advanced call quality

NOTE

THE SELECTIONS MADE IN THIS MENU WILL OVERRIDE THE SELECTIONS MADE IN THE ‘CALL QUALITYMENU.

IF ‘AUTOIS SELECTED, THE SETTINGS IN ‘CALL QUALITYWILL BE USED.

Audio

 

 

 

Auto

The setting of ‘Audio: Auto/High/Normal’ in ‘Call Quality’ will be used.

G.722.1

Compressed high quality audio (7 kHz).

 

G.722

High quality audio (7 kHz).

 

G.728

Compressed normal quality audio (telephone quality, 3.1 kHz).

G.711

Normal quality audio (telephone quality, 3.1 kHz).

 

Off

No audio is transmitted.

 

Video

 

 

 

Auto

Optimized video quality depending on

 

 

 

RESOLUTION, AUTO FUNCTIONALITY

TIP

 

available bandwidth.

 

 

(IF SUPPORTED BY FAR END):

 

 

 

H.263

Bandwidth efficient video compression

WHEN VIDEO: MOTION’ :

 

and decompression.

LOW BANDWIDTHS: CIF, SIF

 

HIGH BANDWIDTHS: ICIF,ISIF

H.261

Normal video compression and decompression.

WHEN VIDEO: SHARPNESS’ :

Off

No video is transmitted.

4CIF, 4SIF, VGA, SVGA

Resolution

 

 

 

 

 

 

Auto

The setting of ‘Video: Auto/Motion/Sharpness’ in ‘Call Quality’ will be used, see

 

tip above.

 

4CIF *

Digital Clarity (704 x 576 pixels), only for H263.

 

iCIF

Natural Video (352 x 576 pixels for PAL, 352x480 pixels for NTSC), only for H263.

CIF

High resolution video (352 x 288 pixels).

 

QCIF

Low resolution video (176 x 144 pixels)

 

H.331

 

 

 

Off

Standard two-way communication with quality negotiation between both sides.

On

Used when broadcasting a video conference from one site to many others, e.g. via

 

satellite, where there is no possibility to negotiate quality between the receivers

 

and the originator due to one-way communication.

 

Status Format

 

 

 

Provides call quality feedback on the status line.

 

Auto

Video off/on, Audio off/normal/high

 

Advanced

Shows video/audio standards (Example: Video: H261 CIF, Audio: G722).

* - Requires option ‘Presenter’. To check which options are installed, see the ‘System Info’ menu in ‘Diagnostics’.

57

Image 57
Contents Health Care System Declaration of Conformity Copyright 2001, Tandberg For the customers in the USA Symbols Location This Symbol IndicatesPrecautions On SafetyOn Installation On Repacking On CleaningOn Mobility On StorageContents Getting Started Advanced use Rsvp NAT 100 TIP IntroductionAt a Glance The HCS III System Camera Main HCS III CartMicrophone MonitorCart Keyboard and Mouse customer suppliedHeadset and Jack Remote ControlRear Interface Panel Network Terminating UnitsMobile Camera Cart optional Height Adjustable Camera ArmIntroduction Health Care System Unpacking InstallationInstallation Health Care System Connecting the SystemHealth Care System Installation To connect a video cassette recorder VCR VCRDual NET 1 External Network Interface Isdn BRI CablesPRI Interface LAN CableInstalling a PC Main HCS III Cart MicrophoneMicrophone 3 MIC Ancillary Equipment Cart Adjustments Triple-pivot Arm Counterbalance AdjustmentMonitor Suspension Arm Adjustment Operational Considerations Brightness Control Loudspeaker VolumeIris Control and Lighting BackgroundLighting Guidelines for setting up videoconferencing roomsGetting Started System start-upWelcome menu Quick Keys BasicsMain Menu Menu StructureMenu System configurationLAN configuration Isdn configurationMaking a call Making and ending callsType of calls Selecting / setting default quality bandwidthAnswer a call Selecting / setting default networkEnd a call Correcting keying mistakesDirectory Add New Entry Delete EntryEdit Entry Add Site Add MultiSite EntryDo Not Disturb / Sleep Mode Adjusting volumeGeneral use View outgoing video selfviewControlling the Main Camera Focusing cameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning SetupActivating DeactivatingSelecting presets PresetsStoring presets Far end camera control FeccSending a still image Sending/receiving still imagesViewing a still image Receiving a still imageAdd Duo Video Duo VideoEnd a Duo Video call MultiSite MCU MultiSite cascading Establishing MultiSite meetings using DirectoryPress ‘Add Site’ to bring up the MultiSite dial menu Adding an extra site dial outAdding an extra site dial Disconnecting sites from a conferencePC SoftPresenter PC PresenterText Chat / Closed Captioning Web-interfaceStreaming Other PC applicationsMain menu Advanced useCall quality VGA ResolutionsAudio VideoAdvanced call quality Presentations Utilities Welcome Menu Continuous PresenceMCU status line System Name MCU servicesRequest floor Quick MenuRelease floor Terminal NamesChair control Audio Settings Mix ModeAudio Inputs Audio Outputs Level SettingsLevel Settings Outputs Echo ControlNoise Reduction Automatic Gain Control AGC Settings Room SizeMotion Alert Tones & Volume Tips for improving the echo canceller performanceRestore Audio Defaults Alert SpeakerVideo Settings Video Name VGA SettingsVGA Out VGA Out QualityPassword VNC SettingsStart using VNC AddressNetwork Configuration Terminal SettingsIsdn Switch Type ISDN-BRI SettingsLine Setup Subaddress Advanced Isdn settingsISDN-PRI Settings PRI Switch TypeNumber Channel Hunting Below is a list of common ISDN-PRI/T1 switchesAdvanced ISDN-PRI Settings Line SettingsExternal network settings Leased E1/T1 SettingsNetwork clocking Call controlAddress Port LAN SettingsTTL/Router Hops Streaming SourceSettings IP Type of Service TOS Advanced H.323 SettingsPrefix RegisterNAT Address IP SettingsIP-assignment IP-addressRestart Snmp SettingsAccess Code Call SettingsIncoming MCU calls Incoming telephone callsEncryption Max Call LengthNetwork Profiles Dataport Dataport configurationLanguage Software OptionsDataport Diagnostics System infoChannel status Call status Restore defaultsTest subsystem View current settingsFar End Loop Isdn only System SelftestConnecting Connecting the HCS III to Isdn using Network AdaptersConfiguring AppendixUsing Telesync TS-256 SW56/ISDN adapter Connecting the system to the Switched 56 networkConfiguration of Telesync Adapter Configuration of the systemConnecting the system to PRI/T1 Using CSU adapterConnecting to Adtran T1 ESF CSU ACE Configuration of Adtran T1 ESF CSU ACE Environmental considerations Description of the different files Using the file systemB2 ABC Appendix 6 Access CodeTechnical Description 101 102 Abbreviations Index Symbols105 USA Servicing