TANDBERG D50104-15 For the customers in the USA, Symbols Location This Symbol Indicates

Page 4

Health Care System III

Warning

While no currently available technology can completely substitute for the in-person physical examination of an individual patient or specimen, the TANDBERG products provide high quality, high resolution, long distance images. When used properly, these Healthcare products can provide a significant and valuable tool for physicians and other medical professionals who are unable to examine a patient or specimen in person. The use and value of the system will vary depending on the specific circumstances of the patient’s condition. Ultimately, judgements on how this tool should be used must be in the individual discretion of physician supervising the patient’s care.

For the customers in the USA

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

Important safeguards/notices for use in the medical environments

1)All the equipment connected to this system shall be certified according to Standard IEC601-1 or other IEC/ISO/CSA/UL Standards applicable to the equipment.

2)When this system is used together with other equipment in the patient area*, the equipment shall be either powered by an isolation transformer or connected via an additional protective earth terminal to system ground unless it is certified according to Standard IEC601-1 and IEC601-1-1.

Note: The power outlets provided in the system are powered from an isolation transformer.

*Patient Area

Symbols

Location

This Symbol

 

 

Indicates

 

 

 

 

 

The equipotential

 

Rear panel

terminal which brings

 

of monitor

the various parts of a

 

 

system to the same

 

 

potential.

 

 

 

 

Rear panel

Functional earth

 

of monitor

terminal

 

 

 

 

Rear panel of

Attention, consult

 

monitor and

ACCOMPANYING

 

power bar

DOCUMENTS

 

 

 

3)The leakage current could increase when connected to other equipment.

4)The operator should take precautions to avoid touching the rear panel input and output circuitry and the patient at the same time.

5)The main power switch of the system is not easily accessible. To isolate the system from the mains supply remove the mains plug from the wall socket.

4

Image 4
Contents Health Care System Declaration of Conformity Copyright 2001, Tandberg Symbols Location This Symbol Indicates For the customers in the USAOn Safety PrecautionsOn Installation On Cleaning On RepackingOn Mobility On StorageContents Getting Started Advanced use Rsvp NAT 100 Introduction TIPAt a Glance The HCS III System Main HCS III Cart CameraMicrophone MonitorKeyboard and Mouse customer supplied CartRemote Control Headset and JackRear Interface Panel Network Terminating UnitsHeight Adjustable Camera Arm Mobile Camera Cart optionalIntroduction Health Care System Installation UnpackingConnecting the System Installation Health Care SystemHealth Care System Installation VCR To connect a video cassette recorder VCRDual Isdn BRI Cables NET 1 External Network InterfacePRI Interface LAN CableMain HCS III Cart Microphone Installing a PCMicrophone 3 MIC Ancillary Equipment Triple-pivot Arm Counterbalance Adjustment Cart AdjustmentsMonitor Suspension Arm Adjustment Brightness Control Loudspeaker Volume Operational ConsiderationsIris Control and Lighting BackgroundGuidelines for setting up videoconferencing rooms LightingSystem start-up Getting StartedWelcome menu Basics Quick KeysMenu Structure Main MenuSystem configuration MenuIsdn configuration LAN configurationMaking and ending calls Making a callSelecting / setting default quality bandwidth Type of callsSelecting / setting default network Answer a callEnd a call Correcting keying mistakesDirectory Delete Entry Add New EntryEdit Entry Add MultiSite Entry Add SiteAdjusting volume Do Not Disturb / Sleep ModeGeneral use View outgoing video selfviewFocusing camera Controlling the Main CameraSelecting video sources Moving / zooming cameraSetup Voice Activated Camera PositioningActivating DeactivatingPresets Selecting presetsStoring presets Far end camera control FeccSending/receiving still images Sending a still imageViewing a still image Receiving a still imageDuo Video Add Duo VideoEnd a Duo Video call MultiSite MCU Establishing MultiSite meetings using Directory MultiSite cascadingAdding an extra site dial out Press ‘Add Site’ to bring up the MultiSite dial menuDisconnecting sites from a conference Adding an extra site dialPC Presenter PC SoftPresenterWeb-interface Text Chat / Closed CaptioningOther PC applications StreamingAdvanced use Main menuVGA Resolutions Call qualityAudio VideoAdvanced call quality Presentations Utilities Continuous Presence Welcome MenuMCU status line MCU services System NameQuick Menu Request floorRelease floor Terminal NamesChair control Mix Mode Audio SettingsAudio Inputs Level Settings Audio OutputsEcho Control Level Settings OutputsNoise Reduction Room Size Automatic Gain Control AGC SettingsMotion Tips for improving the echo canceller performance Alert Tones & VolumeRestore Audio Defaults Alert SpeakerVideo Settings VGA Settings Video NameVGA Out VGA Out QualityVNC Settings PasswordStart using VNC AddressTerminal Settings Network ConfigurationISDN-BRI Settings Isdn Switch TypeLine Setup Advanced Isdn settings SubaddressPRI Switch Type ISDN-PRI SettingsNumber Below is a list of common ISDN-PRI/T1 switches Channel HuntingLine Settings Advanced ISDN-PRI SettingsLeased E1/T1 Settings External network settingsCall control Network clockingLAN Settings Address PortTTL/Router Hops Streaming SourceSettings Advanced H.323 Settings IP Type of Service TOSPrefix RegisterIP Settings NAT AddressIP-assignment IP-addressSnmp Settings RestartCall Settings Access CodeIncoming MCU calls Incoming telephone callsMax Call Length EncryptionNetwork Profiles Dataport configuration DataportSoftware Options LanguageDataport System info DiagnosticsChannel status Restore defaults Call statusView current settings Test subsystemFar End Loop Isdn only System SelftestConnecting the HCS III to Isdn using Network Adapters ConnectingConfiguring AppendixConnecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapterConfiguration of Telesync Adapter Configuration of the systemUsing CSU adapter Connecting the system to PRI/T1Connecting to Adtran T1 ESF CSU ACE Configuration of Adtran T1 ESF CSU ACE Environmental considerations Using the file system Description of the different filesAppendix 6 Access Code B2 ABCTechnical Description 101 102 Abbreviations Symbols Index105 Servicing USA