Warning on power connection

Use a proper power cord for your local power supply. NEVER USE AN EXTENSION CABLE TO POWER THE SYSTEM.

 

United States

Canada

Continental Europe

 

 

 

 

Plug type

Hospital Grade

Hospital Grade

LP-34A

 

 

 

 

Female end

E41395

LL33182

LS-60

 

 

 

 

Cord type

E41395-A

LL76662

H05VV-F

 

 

 

 

Safety approval

10A/125V

10A/125V

10A/250V

 

 

 

 

Minimum cord set rating

UL

CSA

VDE

 

 

 

 

Precautions

On Safety

For your protection, please read these safety instructions completely before operating the equipment and keep this manual for future reference. The information in this summary is intended for persons who operate the equipment as well as repair personnel. Carefully observe all warnings, precautions and instructions on the apparatus, or the one described in the operating instructions and adhere to them. Also for your protection, the instruction manual for the monitor, LCD display (optional), mobile camera (optional) are provided.

Operate the unit on 120 or 240 VAC only, as indicated on the nameplate of the system, which is located on the side of the housing compartment at the bottom of the cart.

Should any solid object or liquid fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it any further.

Unplug the system from the wall outlet during lightning storms or if it is not to be used for several days or more.

To disconnect the system main power cord, pull it out by grasping the plug. Never pull the cord itself.

The socket-outlet shall be installed near the equipment and shall be easily accessible.

Be sure to connect the main power cord to a grounded outlet.

Do not use attachments not recommended by the manufacturer, as they may cause hazards.

On Installation

Allow adequate air circulation to prevent internal heat build-up. Do not block any of the ventilation openings of the apparatus.

Do not install the system in a location near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive dust, mechanical vibration or shock.

Route the power cord to avoid it being walked on or pinched by items placed on or against it, paying particular attention to the plug, receptacle, and the point where the cord enters the unit.

5

Image 5
Contents Health Care System Declaration of Conformity Copyright 2001, Tandberg For the customers in the USA Symbols Location This Symbol IndicatesOn Installation PrecautionsOn Safety On Repacking On CleaningOn Mobility On StorageContents Getting Started Advanced use Rsvp NAT 100 TIP IntroductionAt a Glance The HCS III System Camera Main HCS III CartMicrophone MonitorCart Keyboard and Mouse customer suppliedHeadset and Jack Remote ControlRear Interface Panel Network Terminating UnitsMobile Camera Cart optional Height Adjustable Camera ArmIntroduction Health Care System Unpacking InstallationInstallation Health Care System Connecting the SystemHealth Care System Installation To connect a video cassette recorder VCR VCRDual NET 1 External Network Interface Isdn BRI CablesPRI Interface LAN CableMicrophone 3 MIC Installing a PCMain HCS III Cart Microphone Ancillary Equipment Monitor Suspension Arm Adjustment Cart AdjustmentsTriple-pivot Arm Counterbalance Adjustment Operational Considerations Brightness Control Loudspeaker VolumeIris Control and Lighting BackgroundLighting Guidelines for setting up videoconferencing roomsWelcome menu Getting StartedSystem start-up Quick Keys BasicsMain Menu Menu StructureMenu System configurationLAN configuration Isdn configurationMaking a call Making and ending callsType of calls Selecting / setting default quality bandwidthAnswer a call Selecting / setting default networkEnd a call Correcting keying mistakesDirectory Edit Entry Add New EntryDelete Entry Add Site Add MultiSite EntryDo Not Disturb / Sleep Mode Adjusting volumeGeneral use View outgoing video selfviewControlling the Main Camera Focusing cameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning SetupActivating DeactivatingSelecting presets PresetsStoring presets Far end camera control FeccSending a still image Sending/receiving still imagesViewing a still image Receiving a still imageAdd Duo Video Duo VideoEnd a Duo Video call MultiSite MCU MultiSite cascading Establishing MultiSite meetings using DirectoryPress ‘Add Site’ to bring up the MultiSite dial menu Adding an extra site dial outAdding an extra site dial Disconnecting sites from a conferencePC SoftPresenter PC PresenterText Chat / Closed Captioning Web-interfaceStreaming Other PC applicationsMain menu Advanced useCall quality VGA ResolutionsAudio VideoAdvanced call quality Presentations Utilities MCU status line Welcome MenuContinuous Presence System Name MCU servicesRequest floor Quick MenuRelease floor Terminal NamesChair control Audio Inputs Audio SettingsMix Mode Audio Outputs Level SettingsNoise Reduction Level Settings OutputsEcho Control Motion Automatic Gain Control AGC SettingsRoom Size Alert Tones & Volume Tips for improving the echo canceller performanceRestore Audio Defaults Alert SpeakerVideo Settings Video Name VGA SettingsVGA Out VGA Out QualityPassword VNC SettingsStart using VNC AddressNetwork Configuration Terminal SettingsIsdn Switch Type ISDN-BRI SettingsLine Setup Subaddress Advanced Isdn settingsNumber ISDN-PRI SettingsPRI Switch Type Channel Hunting Below is a list of common ISDN-PRI/T1 switchesAdvanced ISDN-PRI Settings Line SettingsExternal network settings Leased E1/T1 SettingsNetwork clocking Call controlAddress Port LAN SettingsTTL/Router Hops Streaming SourceSettings IP Type of Service TOS Advanced H.323 SettingsPrefix RegisterNAT Address IP SettingsIP-assignment IP-addressRestart Snmp SettingsAccess Code Call SettingsIncoming MCU calls Incoming telephone callsNetwork Profiles EncryptionMax Call Length Dataport Dataport configurationDataport LanguageSoftware Options Channel status DiagnosticsSystem info Call status Restore defaultsTest subsystem View current settingsFar End Loop Isdn only System SelftestConnecting Connecting the HCS III to Isdn using Network AdaptersConfiguring AppendixUsing Telesync TS-256 SW56/ISDN adapter Connecting the system to the Switched 56 networkConfiguration of Telesync Adapter Configuration of the systemConnecting to Adtran T1 ESF CSU ACE Connecting the system to PRI/T1Using CSU adapter Configuration of Adtran T1 ESF CSU ACE Environmental considerations Description of the different files Using the file systemB2 ABC Appendix 6 Access CodeTechnical Description 101 102 Abbreviations Index Symbols105 USA Servicing