Condensate pump drain installation. The condensate drain line is coiled inside the equipment, allowing you to route the condensate drain line for either top or bottom use. See the table “Piping and electrical access locations” on page 11 for more information. Use the provided grommets to properly secure and protect the condensate drain line.

Note: Comply with all local codes when installing the condensate drain line to the proper drain system.

Top routing

Bottom routing

Chiller

There are three types of chillers to which the equipment can be connected:

APC size-matched chiller/thermal storage system

Building chilled water system

Existing dedicated chiller

na1576a

See the chiller documentation: (installation, operation, and maintenance manuals) for proper installation procedures.

CDU

See the CDU Installation manual for proper installation procedures.

Accessories and spare parts

Accessories are available for the equipment, including flexible pipe adapters, data troughs, data partitions, and height adapters for use with other APC equipment. For more information, contact APC as directed on the back cover of this manual.

Many serviceable components are available as spare parts. For more information, contact APC as directed on the back cover of this manual.

InRow RC Installation

19

Image 25
Contents Installation 동봉된 CD 안에 한국어 매뉴얼이 있습니다 American Power Conversion Legal Disclaimer Page Contents Mechanical Connections Manual updates Cross-reference symbol used in this manual SafetyOverview Damage to Equipment or Personnel Inspecting the Equipment Installation kitInventory Door and side panel locksExterior Component IdentificationInterior User interface connection panel Room Preparation Incoming power supply requirementsWith cooling distribution unit CDU Piping DiagramsTop piping InRow Bottom piping To customer Supplied chiller Without CDUOut From Coils FullFull Bypass Open Internal piping diagramDimensions are shown in mm Piping and electrical access locationsWeights and Dimensions Door removal Side panel removal Removing Doors and PanelsPositioning the Equipment Service accessLeveling Floor brackets Stabilizing the EquipmentJoining to enclosures Piping Mechanical ConnectionsConnect piping Condensate pump drain connection Chiller Accessories and spare partsFilling and Purging Than 76 l/m 20 gpm Electrical Connections Power connections Control Modbus User interface connection pinoutLink ports Network port Modbus Control connectorLeak detector port Form C alarm contacts and shutdown inputTemperature sensor 990-2402D-001 11/2012 APC Worldwide Customer Support