SUPER MICRO Computer 6113L-i, 6113L-8 Adding PCI Cards, PCI-X slot, PCI card installation

Page 49

Chapter 5: Advanced Serverboard Setup

5-6 Adding PCI Cards

1.PCI-X slot:

The i2DML-8G2/i2DML-iG2 has one 64-bit 133 MHz PCI-X slot. The server should have come with a riser card installed, which supports a standard sized PCI-X card (see Figure 5-7).

2.PCI card installation:

Before installing a PCI add-on card, see step 1, above. Begin by swinging the release tab on the I/O backpanel shield out to the left for the PCI slot. Insert the PCI card into the correct slot on the butterfly riser card (depending on whether it is a standard or low-profile card), pushing down with your thumbs evenly on both sides of the card. Finish by pushing the release tab back to its original (locked) position. Follow this procedure when adding a card to either slot.

Figure 5-7. Low Profile vs. Standard PCI Card Form Factor

Standard PCI

Expansion Card

Low Profile PCI

Expansion Card

5-13

Image 49
Contents Super Page About This Manual PrefaceManual Organization Advanced Chassis Setup Advanced Serverboard SetupBios Preface Table of Contents Advanced Serverboard Setup System SafetyBios Advanced Chassis SetupAppendices Appendix a Bios Error Beep CodesPage Overview Chapter IntroductionChipset Serverboard FeaturesPCI Expansion Slots Processors MemoryATI Graphics Controller Onboard Controllers/PortsE8870 Chipset Block Diagram Other FeaturesSystem Power Server Chassis FeaturesControl Panel BackplaneCooling System Headquarters Contacting SupermicroEurope Asia-PacificPage Preparing for Setup Chapter Server InstallationUnpacking the SuperServer 6113L-8/6113L-i Rack Precautions Choosing a Setup LocationServer Precautions Installing the Outer Rails Installing the Server into a RackIdentifying the Sections of the Rack Rails Installing the Rack Rails Installing the Server into the RackInstalling the Server into a Rack Front bezel is optional Installing the Server into a Telco Rack Checking the Serverboard Setup Page Checking the Drive Bay Setup Page Control Panel Buttons Chapter System InterfaceControl Panel LEDs Scsi Drive Carrier LEDs 6113L-8 only Page Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Operating Precautions Precautions Chapter Advanced Serverboard SetupHandling the i2DML-8G2/i2DML-iG2 Serverboard UnpackingLocating the Components Itanium2 Processor and Heatsink InstallationInstalling Heatsink Retention Mechanism Installing the Heatsink Retention MechanismPointer Installing Itanium2 CPUsCPU power pod Installing the Power PodsPower pod slot Pins of the CPU are notDual Itanium2 CPUs with Power Pods Installed Installing Heatsinks for CPUs without heatsinks CPUs 2 with Heatsinks Installed Connecting AC PowerConnecting Data Cables Connecting CablesConnecting Power Cables Front Control Panel Header Pins U66 Connecting the Control PanelDimm Installation See Figure Installing MemoryI/O Ports Memory Support 6a. Side View of Dimm Installation into SocketAdding PCI Cards PCI card installationPCI-X slot Super i2DML-8G2 Serverboard DetailsConnector Description Jumper Description Default SettingI2DML-8G2/i2DML-iG2 Quick Reference Connector Definitions Overheat LED OH HDD LEDPower Button Reset ButtonUniversal Serial Bus USB0/1 Serial Ports Front Panel Universal Serial Bus HeaderGlan Ethernet Ports Chassis IntrusionFan Headers Power FaultWake-On-Ring SMB SMB Power I2C ConnectorVGA Enable/Disable Jumper SettingsExplanation Jumpers Cmos ClearWatch Dog Enable/Disable Glan Enable/DisablePower Fail Alarm Enable/ Disable Scsi Enable/Disable 6113L-8 only Onboard IndicatorsGlan LEDs Debug LEDsScsi and IDE Disk Drive Connections IDE ConnectorsScsi Activity LED 6113L-8 only Pin Ultra 320 Scsi Connectors J3 and J18 Ultra320 Scsi Connectors 6113L-8 onlyStatic-Sensitive Devices Chapter Advanced Chassis SetupTools Required Chassis Front and Rear Views Control PanelSystem Fan Failure System FansReplacing System Fans Removing the Front Bezel Drive Bay Installation/RemovalRemoving the Front Bezel Accessing the Drive BaysMounting a SCSI/IDE drive in a drive carrier SCSI/IDE Drive InstallationInstalling/removing hot-swap Scsi drives 6113L-8 only CD-ROM Drive Installation Power Supply Failure Power SupplyRemoving/Replacing the Power Supply Removing the power supplyRemoving/Replacing the Power Supply Introduction ChapterLanguage Menu Main Setup ScreenBSP Information System Time/System DateSuper IO Configuration Advanced Setup ScreenSerial Port1 Address/Serial Port2 Address IDE ConfigurationPrimary IDE Master/Slave, Secondary IDE Master/Slave LBA/Large ModeType Block Multi-Sector TransferA.R.T. For Hard disk drives DMA ModeBit Data Transfer Armd Emulation TypeQuiet Boot Bios Settings ConfigurationAtapi 80-Pin Cable Detection System Health Monitor Power Loss Control Peripheral Device ConfigurationWatch Dog Timer Watch Dog Timer ValueUSB Function USB ConfigurationLegacy USB Support PCI Latency Timer PCI/PnP ConfigurationAllocate IRQ to PCI VGA PCI IDE BusMasterOverheat Temperature Trips Security SettingsChange Supervisor Password Hardware Health Monitoring Health FunctionClear User Password Change User PasswordExit Options Exit Saving ChangesLoad Fail-Safe Defaults Load Optimal DefaultsDiscard Changes IA-32 Error Beep Codes Appendix a Bios Error Beep CodesBeep Code Error Message Description Checkpoints Code Description IA-64 Common Debug CodesCheckpoint Code Description Appendix B Bios Post CodesRegister for date and time next Monochrome mode and color mode settings next 47h 60h 95h Introduction to the EFI Platform Appendix C Software InstallationAmibios Flash Page Page Page Adding the CD-ROM Boot Option in EFI IA64 OS Installation Page Appendix D System Specifications Power Supply WeightSystem Cooling System Input Requirements