Western Telematic RPC-4840N manual Reset Unit to Defaults, Default Button / Reset Button Local

Page 17

Installation

4.3. Reset Unit to Defaults

If Option Switch settings are changed, the new settings will not be applied until the unit is reset to default settings. There are two ways to reset the unit to defaults:

Note: When these reset procedures are performed, all user selected parameters, including passwords and circuit names will be lost. Prior to performing these reset procedures, it is strongly recommended to save configuration parameters to an ASCII text file as described in Section 7.

4.3.1.Default Button / Reset Button (Local)

Typically, this method is used when you have immediate access to the installation site.

1.Simultaneously press the DEFAULT and RESET buttons, located on the RPC Back Panel.

2.Release the RESET button, wait for approximately five seconds, and then release the DEFAULT button.

4.3.2.Default Parameters Option

To reset the unit to default parameters using the General Parameters Menu's "Default Parameters" option, proceed

as follows. Note that this method requires that you have already connected a local or remote PC to the unit and have accessed the command mode.

1.Access the RPC Command Mode (see Section 6.1).

2.At the RPC> command prompt, type /G and press [Enter]. The General Parameters menu will appear.

3.From the General Parameters menu, type A and press [Enter]. If command confirmation is enabled, the unit will display a "Sure?" prompt. Type Y and press [Enter] to proceed with the reset procedure. After a brief pause, parameters will be reset to default values.

Note: If the Default Parameters function is invoked

via the Network Port, the IP Address will not be

 

reset. If this function is invoked via the Console

 

Port or Modem Port, the IP Address will be reset.

4-3

Image 17
Contents WTIPartNo.Rev13224.A Page Rack Mount Installation Nameplate Power WarningVentilation Disconnect Power7iii-2 Curiy ServiceIntroduction Intelligent Power ControlTypographic Conventions FeaturesBack Panel Unit DescriptionFront Panel 2BackPanel Quick Start Guide Page QuickStartGuide RPC-4840NRemotePowerControllerUsersGuide Power Connection InstallationDisconnect Timeout Option SwitchesDefault Parameters Option Reset Unit to DefaultsDefault Button / Reset Button Local Console Port Connection Connecting an External ModemConnecting the Network Cable System Mode and User Mode ConfigurationCommunicating with the RPC-4840N Ckt Defining General Parameters Command/Menu ConventionsOff RPC-4840NRemotePowerControllerUsersGuide Circuit Parameters Configuration4CircuitParametersMenuCircuit1Shown Network Parameters UndefinedImplementing IP Security Configuration Save Configuration Parameters Operation Access the Command ModeHfor Dischelp mrmaio Displaying circuit StatusOperation Boot/On/Off CommandsOFF POWER2 or /OF POWER2 and press Enter Automated Mode Default CommandRPC-4840NRemotePowerControllerUsersGuide Login as Different User Other CommandsReset Network Port Exit / DisconnectOperating Tips Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Modem Port Interface Interface DescriptionsConsole Port Interface Physical / Environmental Operating Temperature 0C to 45C SpecificationsTrademark and Copyright Information Customer ServiceApx-4 10BaseT100BaseT........#.........2-1,4-4 IndexSystemPassword