Omega 308, DAQP-208, 208H user manual Device = C\DAQPACL.SYS

Page 17

2.4.1.1 Client Driver Command Line Options

The DAQP series Client Driver accepts up to eight command line arguments from the user to determine the configuration of the DAQP card. If any arguments are provided, the Client Driver will attempt to configure any DAQP card with the options specified in the order they are entered on the command line. Each argument must be enclosed in parenthesis and must be separated from other arguments by a space in the command line. Inside an argument, a comma (no space) should be used to separate the parameters from each other if there are two or more parameters. Within each argument, any or all of the following parameters may be specified:

b

address

Specifies the base I/O address of the DAQP card in hexadecimal. “Address”

 

 

must be in the range 100H - 3F8H and must reside on an even 8-byte boundary

 

 

(“address” must end in 0 or 8). If this option is omitted, a base address will be

 

 

assigned by Card and Socket Services software.

i

irq

Specifies the interrupt level (IRQ) of the DAQP card in hexadecimal. “Irq” must

 

 

be one of the following values: 3, 4, 5, 7, 9, 10, 11, 12, 14, 15 or 0 if no IRQ if

 

 

desired. If this option is omitted, an interrupt level will be assigned by Card

 

 

and Socket Services software.

s

socket

Specifies the PCMCIA socket number to configure. “Socket” must be in the

 

 

range 0 - 15. If this option is omitted, the configuration argument will be applied

 

 

to any available DAQP card inserted into any socket in the system.

2.4.1.2 Client Driver Installation Examples

With the Client Driver, the user may specify a list of selections (in the form of command line arguments) for the configuration of the DAQP series cards. The Client Driver scans this list from left to right until it finds a selection that is currently available in the system. If none of the preferred selections are available, the Client Driver requests a configuration from Card and Socket Services software.

Example 1

DEVICE = C:\DAQPA_CL.SYS

In example 1, no command line arguments are specified. The Client Driver will configure the DAQP card into ANY socket with a base address and IRQ level assigned by Card and Socket Services.

Example 2

DEVICE = C:\DAQPA_CL.SYS (b300)

In this example, a single command line argument is provided. The Client Driver will attempt to configure a DAQP card inserted into ANY socket with a base address of 300H and an IRQ level assigned by Card and Socket Services. If the base address 300H is not available, the DAQP card will NOT be configured.

DAQP-208/208H/308 Users Manual

17

Image 17
Contents Type II Pcmcia Data Acquisition Adapter s DAQP-208/208H/308WARRANTY/DISCLAIMER Servicing Europe Servicing North AmericaFor immediate technical or application assistance Page Page Table of Contents Page List of Figures and Tables Daqp Series Card Output ConnectorIntroduction Hardware Configuration and Initial Setup Page Software Installation Windows NT Page Data Acquisition Software and Drivers DAQPACL.SYS DAQPAEN.EXE Page Device = C\DAQPACL.SYS Device = C\DAQPACL.SYS b300,i5 Page Page Page Device = C\DAQPAEN.EXE S0,r GND DA0 DA1 Field WiringGND CP-DAQPA Cable AssemblyDaqp Series Card Cable Mapping UIO-37 Terminal Block UIO-37 Screw Terminal BlockTheory of Operation DC/DC Power SupplyProgrammable Gain Control Amplifier Analog Input MultiplexerScan List Register Trigger Circuit A/D Converter and Data Fifo Digital I/O Interrupt and StatusFifo A/D State Machine10 D/A Circuit Timer/CounterPage Pcmcia Interface O RegistersSreset Address Map Bit Page Data Fifo Threshold Setting LSB 1080 Select channel 0, gain 2, 1st entry Page Page Page Page Digital input bit External gain select, high bit All Output Flush scan list command High byte of the almost full threshold 15 2K option 18. D/A Data Port Bit Definition Bits Explanation 15-13 19. D/A Update Modes 20. Timer/Counter Modes Page Page Page Specifications TTL DAQP-208/208H/308 Version April 12