Example 3

DEVICE = C:\DAQPA_CL.SYS (s0,b300,i5)

Example 3 is also a single command line argument. The client Driver will attempt to configure the DAQP card inserted in socket 0 at base address 300H and IRQ level 5. If either address 300H or IRQ level 5 is unavailable, the card will NOT be configured. In addition, the Client Driver will NOT configure any DAQP card inserted into any socket except socket 0.

Example 4

DEVICE = C:\DAQPA_CL.SYS (b300,i5) (i10) ( )

Three command line arguments are provided in this example. The Client Driver will first attempt to configure a DAQP card inserted into any socket with a base address 300H and IRQ level 5. If either address 300H or IRQ level 5 is unavailable, the Client Driver will proceed to the second command line argument and attempt to configure the card with a base address assigned by the Card and Socket Services and IRQ level 10. If IRQ level 10 is also unavailable, the Client Driver will then go to the third command line argument and attempt to configure it with a base address and an IRQ level assigned by Card and Socket Services.

Example 5 DEVICE = C:\DAQPA_CL.SYS (b300,i5) ( ) (i10)

The difference between example 5 and example 4 is the order of the second and third command line arguments. The Client Driver will first attempt to configure a DAQP card inserted into any socket with a base address 300H and IRQ level 5. If either address 300H or IRQ level 5 is unavailable, the Client Driver will proceed to the second command line argument and attempt to configure the card with a base address and IRQ level assigned by Card and Socket Services. Since the second command line argument includes all available address and IRQ resources, the third command line argument will never be reached by the Client Driver. The user must ensure command line arguments are placed in a logical order.

Example 6

DEVICE = C:\DAQPA_CL.SYS (s0,b300,i5) (s1,b310,i10)

There are two command line arguments in example 6, which is desirable in systems where two or more DAQP cards are to be installed. The Client Driver will attempt to configure the DAQP card in socket 0 with base address 300H and IRQ 5. If there is a DAQP card in socket 1, it will be configured with base address 310H and IRQ 10. This allows the user to force the card address and IRQ settings to be socket specific as required by software or cable connections. If the requested resources are not available, the DAQP cards will not be configured.

DAQP-208/208H/308 Users Manual

18

Image 18
Contents DAQP-208/208H/308 Type II Pcmcia Data Acquisition Adapter sWARRANTY/DISCLAIMER Servicing North America For immediate technical or application assistanceServicing Europe Page Page Table of Contents Page Daqp Series Card Output Connector List of Figures and TablesIntroduction Hardware Configuration and Initial Setup Page Software Installation Windows NT Page Data Acquisition Software and Drivers DAQPACL.SYS DAQPAEN.EXE Page Device = C\DAQPACL.SYS Device = C\DAQPACL.SYS b300,i5 Page Page Page Device = C\DAQPAEN.EXE S0,r Field Wiring GND DA0 DA1CP-DAQPA Cable Assembly GNDDaqp Series Card Cable Mapping UIO-37 Screw Terminal Block UIO-37 Terminal BlockDC/DC Power Supply Theory of OperationAnalog Input Multiplexer Programmable Gain Control AmplifierScan List Register Trigger Circuit A/D Converter and Data Fifo Interrupt and Status Digital I/OA/D State Machine FifoTimer/Counter 10 D/A CircuitPage O Registers Pcmcia InterfaceSreset Address Map Bit Page Data Fifo Threshold Setting LSB 1080 Select channel 0, gain 2, 1st entry Page Page Page Page Digital input bit External gain select, high bit All Output Flush scan list command High byte of the almost full threshold 15 2K option 18. D/A Data Port Bit Definition Bits Explanation 15-13 19. D/A Update Modes 20. Timer/Counter Modes Page Page Page Specifications TTL DAQP-208/208H/308 Version April 12