Omega 208H, DAQP-208, 308 user manual

Page 58

Table 5-22. Auxiliary Status Register Bit Definition

 

Bit

Function

 

Explanation

 

 

 

 

 

 

 

 

 

 

 

7

A/D running flag

1

= Running, 0 = Idle

 

 

 

 

 

 

 

 

 

6

A/D trigger flag

1

= Triggered, 0 = Not yet

 

 

 

 

 

 

 

 

 

5

D/A port buffer register flag

1

= Occupied, 0 = Empty

 

 

 

 

 

 

 

 

 

4

Timer/Counter overflow event latch

1

= Overflow latched, 0 = Not yet

 

 

 

 

 

 

 

 

 

3

A/D conversion event latched (Logic

1

= Either EOS or FIFO almost full

 

 

 

 

“OR” of A/D EOS and FIFO almost full

 

event has been latched

 

 

 

event latches)

0

= Neither event has been latched yet

 

 

 

 

 

 

 

 

2

Data lost event latch

1

= Data lost latched, 0 = Not yet

 

 

 

 

 

 

 

 

 

1

A/D data FIFO almost full flag

1

= FIFO almost full, 0 = Not yet

 

 

 

 

 

 

 

 

 

0

A/D data FIFO empty flag

1

= FIFO empty, 0 = Not empty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit 4 indicates the timer/counter overflow event. This bit is set to ”1” whenever the timer/counter overflow occurs (on the next rising edge of the selected clock source after it reaches the final count). This bit cannot be cleared by reading the auxiliary status register. It can only be cleared by writing a “0” into bit 5 of the auxiliary control register. Bit 5 is the D/A port buffer register flag and is set to “1” if the register is occupied or “0” if it is empty. With the pre-trigger option selected, bit 6 is set to “1” when the external trigger is received. This bit remains “1” until data acquisition is terminated by receiving the A/D stop command. Bit 6 set to “0” means the trigger has not been received yet. If the pre-trigger option is not selected or bit 6 of the auxiliary control register is set to “0”, then this bit should be ignored. Bit 7 is exactly the same as bit 6 in the status register (base + 2).

DAQP-208/208H/308 Users Manual

58

Image 58
Contents DAQP-208/208H/308 Type II Pcmcia Data Acquisition Adapter sWARRANTY/DISCLAIMER For immediate technical or application assistance Servicing North AmericaServicing Europe Page Page Table of Contents Page Daqp Series Card Output Connector List of Figures and TablesIntroduction Hardware Configuration and Initial Setup Page Software Installation Windows NT Page Data Acquisition Software and Drivers DAQPACL.SYS DAQPAEN.EXE Page Device = C\DAQPACL.SYS Device = C\DAQPACL.SYS b300,i5 Page Page Page Device = C\DAQPAEN.EXE S0,r Field Wiring GND DA0 DA1CP-DAQPA Cable Assembly GNDDaqp Series Card Cable Mapping UIO-37 Screw Terminal Block UIO-37 Terminal BlockDC/DC Power Supply Theory of OperationAnalog Input Multiplexer Programmable Gain Control AmplifierScan List Register Trigger Circuit A/D Converter and Data Fifo Interrupt and Status Digital I/OA/D State Machine FifoTimer/Counter 10 D/A CircuitPage O Registers Pcmcia InterfaceSreset Address Map Bit Page Data Fifo Threshold Setting LSB 1080 Select channel 0, gain 2, 1st entry Page Page Page Page Digital input bit External gain select, high bit All Output Flush scan list command High byte of the almost full threshold 15 2K option 18. D/A Data Port Bit Definition Bits Explanation 15-13 19. D/A Update Modes 20. Timer/Counter Modes Page Page Page Specifications TTL DAQP-208/208H/308 Version April 12