Omnitron Systems Technology GX/TM user manual Passwords

Page 12

3.4CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE

PI

SA

To configure, attach the GX/TM to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. The GX/TM Serial Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a serial cable to the serial port of the PC and the Serial Console Port of the GX/TM. This is a standard asynchronous serial interface. The pin-outs are illustrated below.

Serial Connector Pin Outs

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the PC’s serial port to the following:

Bits Per Second:

57,600

Stop Bits:

1

Data Bits:

8

Parity:

NONE

Hardware Flow Control:

NONE

Power the chassis containing the GX/TM module and press <ENTER> to bring up a command line prompt on the attached PC.

The module is configured with the following defaults:

IP

 

IP Address:

192.168.1.220

IP Subnet Mask:

255.255.255.0

Passwords

 

Serial:

No password assigned

FTP:

No password assigned

Telnet:

public

SNMPv1/v2c Communities

READ:

public

 

 

WRITE:

public

 

 

SNMPv3 Parameters

 

 

 

User 1 name (read only):

guest

 

 

User 2 name (read/write):

admin

 

 

User 1 Privacy pwd:

publicguest

User 1 Authen pwd:

publicguest

User 2 Privacy pwd:

privateadmin

User 2 Authen pwd:

privateadmin

Page 12

Image 12
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 UTP Auto/Manual Negotiation AN/Man 1.3 SW3 UTP Speed Gigabit/10-100 1000/10-100 Board-Mounted Bank 2 Settings These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed GX/TM Setting IP Parameters as Dhcp Client Setting GX/TM Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Enabling/Disabling Soft-switch Reload Access the GX/TM Remotely Updating the GX/TM Firmware via the Serial Console Port Updating the GX/TM Firmware via FTP Verify Operation Detailed Module Configuration NMMGX/TM UTP UTP HDX UTP FDXLED Module Management Mode Port Configuration Port Access A167EC500000 3 802.3ah Parameters OUI 4 802.3ah Events Port Vlan Page Tagged Vlan Pvid Vlan ID VID UTP BP a BP BVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter GX/TM Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty