Omnitron Systems Technology GX/TM user manual Utp Hdx Utp Fdx, Led

Page 28

PI

Module - iConverter GX/TM

 

iConverter, Serial Agent

 

Identifier -

 

 

 

 

 

 

 

 

Chassis Number

=

1

Switch ON Condition

OFF Condition

H/W

Actual

Slot Number

=

2

1: Fiber Manual

Fiber AN

Off

Off

Model Number

=

8923-1

2: UTP Manual

UTP Auto-Neg

Off

Off

 

 

 

3: UTP

10/100

UTP

1000

Off

Off

Serial Number

=

xxxxxxxx

4: UTP 10 Mbps

UTP 100 Mbps

Off

Off

Manufacturing Date =

xxxxxxxx

5: UTP HDX

UTP FDX

Off

Off

Hardware Revision

=

xx

6: Link Propagate

Link Segment

Off

Off

Software Revision

=

xx

7: Remote Fault

Normal

Off

Off

 

 

 

8: Symm Fault Det

Normal

Off

Off

LED

 

 

9: BP A Enabled

BP A Disabled

Off

Off

1: Power

=

On

10: BP B Enabled

BP B Disabled

Off

Off

2: Power Supply 1

=

Off

11: Pause Enabled

Pause Disabled

Off

Off

3: Power Supply 2

=

On

12: Slave Only

Master/Slave

Off

Off

4: Power Supply 3

=

Off

13: UTP

Manual-X

UTP

Auto-X

Off

Off

5: Fiber Link

=

Off

14: UTP Crossover

UTP Through

Off

Off

6: BP Master

=

Off

15: Not Available

 

 

 

 

7: UTP 100+10 Link =

Off

16: Not Available

 

 

 

 

8: UTP 1000+10 Link=

Off

OAM settings:

 

 

 

 

9: UTP FDX

=

Off

17: IP Protocol State

Off

 

 

 

 

 

18: Management Mode

ah OAM

 

 

Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >

 

The Module configuration screen provides general information concerning the configuration and status of the module. The screen displays the model and serial numbers, hardware and software revisions, as well as the condition of the LEDs and DIP-switches. The DIP-switches can be re-configured (options 1 -12) without removing the module from the chassis. Select the appropriate option to change the DIP-switch setting. Selecting DIP-switch options 1 - 12, will cause the selection to change states under the ‘Actual’ heading.

NOTE: The Plug-In Module configuration screen is shown. The standalone Module configuration screen will display LED 2, 3, 4, and 6 and DIP-switches 9, 10 and 12 as NOT AVAILABLE.

Page 28

Image 28
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 UTP Auto/Manual Negotiation AN/Man 1.3 SW3 UTP Speed Gigabit/10-100 1000/10-100 Board-Mounted Bank 2 Settings These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed GX/TM Setting IP Parameters as Dhcp Client Setting GX/TM Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Enabling/Disabling Soft-switch Reload Access the GX/TM Remotely Updating the GX/TM Firmware via the Serial Console Port Updating the GX/TM Firmware via FTP Verify Operation Detailed Module Configuration NMMGX/TM UTP HDX UTP FDX UTPLED Module Management Mode Port Configuration Port Access A167EC500000 3 802.3ah Parameters OUI 4 802.3ah Events Port Vlan Page Tagged Vlan Pvid UTP BP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter GX/TM Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty