Omnitron Systems Technology GX/TM user manual Board-Mounted Bank 2 Settings

Page 9

3.2.2Board-Mounted Bank 2 Settings

PI

SA

DIP-switch Bank 2 is available on both the plug-in and standalone modules.

PI

SA

Switch

Left (Factory Default)

Right

SW1

A-DS:Port A Disabled

A-EN:Port A Enabled

SW2

B-DS:Port B Disabled

B-EN:Port B Enabled

SW3

Off:

Pause:

 

Pause Disable

Pause Enable

SW4

M/SL:

SL:

 

Master/Slave Auto-Select

Slave-Mode Only

SW5

Auto:

Man:

 

UTP Auto Crossover

UTP Manual Crossover

SW6

=:

X:

 

Manual UTP Straight-Through

Manual UTP Crossover

SW7

Reserved

Reserved

SW8

Reserved

Reserved

Switch

Down (Factory Default)

Up

SW3

Off:

Pause:

 

Pause Disable

Pause Enable

SW4

Reserved

Reserved

SW5

Auto:

Man:

 

UTP Auto Crossover

UTP Manual Crossover

SW6

=:

X:

 

Manual UTP Straight-Through

Manual UTP Crossover

SW7

Reserved

Reserved

SW8

Reserved

Reserved

3.2.2.1SW1 - Backplane Port A Enabled “A-DS/A-EN”

PI

When the DIP-switch is in the Left “A-DS” position (factory default), Backplane Port A of the GX/TM is isolated from the chassis Backplane. When the DIP-switch is in the Right “A-EN” position, Backplane Port A of the GX/TM is enabled. This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port A. See the backplane illustrations in Section 2.1.3.

3.2.2.2SW2 - Backplane Port B Enabled “B-DS/B-EN”

PI

When the DIP-switch is in the Left “B-DS” position (factory default), Backplane Port B is isolated from the chassis Backplane. When the DIP-switch is in the Right “B-EN” position, Backplane Port B is enabled. This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port B. See the backplane illustrations in Section 2.1.3.

3.2.2.3SW3 - Pause Disable/Enable “Off/Pause”

When the UTP port is operating in Auto-Negotiation mode, it advertises for Pause based on the Pause Disable/Enable “Off/Pause” DIP-Switch setting. Setting the Pause DIP-switch to the Pause Disable “Off” position (factory default) forces the UTP port to negotiate to No Pause. Setting this DIP-switch to the Pause Enable “Pause” position allows the UTP port to negotiate to Symmetrical Pause, Asymmetrical Pause or No Pause mode. When the UTP port is operating in Manual mode, Pause is disabled.

NOTE: When the Fiber optic port operates in Auto-Negotiation mode, the port advertises for Pause. When the Fiber optic port operates in Manual mode, Pause is disabled.

3.2.2.4SW4 - Master/Slave Auto-Select and Slave-Only “M/SL / SL

PI

When multiple management modules such as the iConverter NMM and the GX/TM (or multiple self-managed modules such as the 10/100M) are installed in the same chassis, only one management module can act as the chassis master. The master management module has the ability to make changes to the settings of the other modules in the chassis, while the slave management modules cannot make the changes. If an NMM is installed in the chassis, the NMM will always be the master, otherwise the lowest slot number with a management module installed will become chassis master.

When this DIP-switch is in the Left “M/SL” position (factory default), the assignment of mastership is automatically negotiated by the installed management modules. To designate a specific management module as the master when no NMM is installed in the chassis, set the DIP-switch on the master module to the Left “M/SL” position, and set the other installed management modules’ DIP-switches to the Right “SL” position to enable Slave-Only mode.

Only the chassis master can change configuration settings of other modules.

Page 9

Image 9
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 UTP Auto/Manual Negotiation AN/Man 1.3 SW3 UTP Speed Gigabit/10-100 1000/10-100 Board-Mounted Bank 2 Settings These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed GX/TM Setting IP Parameters as Dhcp Client Setting GX/TM Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Enabling/Disabling Soft-switch Reload Access the GX/TM Remotely Updating the GX/TM Firmware via the Serial Console Port Updating the GX/TM Firmware via FTP Verify Operation NMM Detailed Module ConfigurationGX/TM UTP UTP HDX UTP FDXLED Module Management Mode Port Configuration Port Access A167EC500000 3 802.3ah Parameters OUI 4 802.3ah Events Port Vlan Page Tagged Vlan Pvid Vlan ID VID UTP BP a BP BVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types GX/TM SpecificationsPossible Causes Troubleshooting GuideUTP Issues Limitation of Warranty Warranty