Omnitron Systems Technology user manual Setting GX/TM Passwords

Page 16

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis number.

To set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis name.

NOTE: When the NMM is installed into the chassis and is set to Remote OAM, the chassis number of the GX/TM is automatically assigned by the NMM.

PI

SA

IP and Control Preferences Screen

iConverter, Serial Agent

1:

Set IP

 

192.168.1.220

2:

Set Subnet Mask

255.255.255.0

3:

Set Gateway

192.168.1.1

4:

Chassis Number

1

5:

Chassis Name (also sysName)

GX/TM

6:

Enable/Disable TELNET

Enabled

7:

Enable/Disable FTP

Disabled

8:

Enable/Disable Soft Switch Reload

Disabled

9:

TELNET Password

*****

10: FTP

Password

 

11: Serial Password

 

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.1.4Setting GX/TM Passwords

The GX/TM is shipped from the factory without password protection on the Serial Console Port. It is highly recommended that the network administrator set a password in order to prevent unauthorized access to the unit. The password can be any 1-32 character alphanumeric string.

The GX/TM is shipped from the factory with Telnet enabled and FTP disabled. From the IP and Control Preferences screen, select 6 to enable or disable Telnet, and select 7 to enable or disable FTP.

To set the password for Telnet access, select 9 at the IP and Control Preferences screen, press <ENTER> and then follow the screen prompts to enter and verify the password. The default password for Telnet access is “public”.

To set the password for FTP access, select 10 at the IP and Control Preferences screen, press <ENTER> and then follow the screen prompts to enter and verify the password.

To set the password for serial access, select 11 at the IP and Control Preferences screen, press <ENTER> and then follow the screen prompts to enter and verify the password.

Page 16

Image 16
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 UTP Auto/Manual Negotiation AN/Man 1.3 SW3 UTP Speed Gigabit/10-100 1000/10-100 Board-Mounted Bank 2 Settings These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed GX/TM Setting IP Parameters as Dhcp Client Setting GX/TM Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Enabling/Disabling Soft-switch Reload Access the GX/TM Remotely Updating the GX/TM Firmware via the Serial Console Port Updating the GX/TM Firmware via FTP Verify Operation Detailed Module Configuration NMMGX/TM UTP HDX UTP FDX UTPLED Module Management Mode Port Configuration Port Access A167EC500000 3 802.3ah Parameters OUI 4 802.3ah Events Port Vlan Page Tagged Vlan Pvid UTP BP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter GX/TM Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty