Omnitron Systems Technology GX/TM user manual +1 Vlan ID

Page 42

PI

Membership Entry - iConverter GX/TM

iConverter, Serial Agent

Identifier -

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8923-1

VLAN Table Membership Entry 1

 

------------------------------

 

+1: VLAN ID

 

100

 

+2: Fiber Port Membership

Yes

 

3: UTP Port Membership

No

 

4: BP A Port Membership

No

 

5: BP B Port Membership

No

 

6: Mngmnt Port Membership

No

 

*7: Submit Entry As Defined

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

SA

Membership Entry - iConverter GX/TM

 

iConverter, Serial Agent

Identifier -

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8923-1

VLAN Table Membership Entry 1

 

------------------------------

 

+1: VLAN ID

 

100

 

+2: Fiber Port Membership

Yes

 

3: UTP Port Membership

No

 

4: Mngmnt Port Membership

No

 

*5: Submit Entry As Defined

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

Once all the VLAN IDs have been assigned, select option 7 or 5 to submit the entries.

PI

VLAN Membership - iConverter GX/TM

 

iConverter, Serial Agent

Identifier -

 

 

 

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8923-1

 

 

VLAN ID (VID)

Fiber

UTP

BP A

BP B

Mngmnt

1:

100

 

Yes

No

No

No

No

Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

The VLAN membership entries are saved from the Port configuration screen, option 4.

Page 42

Image 42
Contents Standalone and PLUG-IN Module Table of Contents Overview Port Structure Installation Procedure Configuring DIP-SWITCHES 1.2 SW2 UTP Auto/Manual Negotiation AN/Man 1.3 SW3 UTP Speed Gigabit/10-100 1000/10-100 Board-Mounted Bank 2 Settings These DIP-switches are for factory use only Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed GX/TM Setting IP Parameters as Dhcp Client Setting GX/TM Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Vlan ID Enabling/Disabling Soft-switch Reload Access the GX/TM Remotely Updating the GX/TM Firmware via the Serial Console Port Updating the GX/TM Firmware via FTP Verify Operation Detailed Module Configuration NMMGX/TM UTP UTP HDX UTP FDXLED Module Management Mode Port Configuration Port Access A167EC500000 3 802.3ah Parameters OUI 4 802.3ah Events Port Vlan Page Tagged Vlan Pvid Vlan ID VID UTP BP a BP BVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter GX/TM Specifications Cable TypesTroubleshooting Guide Possible CausesUTP Issues Warranty Limitation of Warranty