Omega Speaker Systems RD8300 manual Wiring Specifications and Procedures, Power Requirements

Page 26

Section 3 – Installation

3.4Wiring Specifications and Procedures

3.4.1Power Requirements

The recorder operates on any voltage from 100 to 240 Vac +10%, 50/60 Hz enabling it to be used in most countries. The maximum apparent power required by the unit is 35 VA.

3.4.2 Power Connections

NOTE: The recorder is designed to be panel mounted and as such should be considered as permanently connected. Disconnection from the supply must be possible via a customer supplied switch or circuit breaker. This disconnection device must be included in the panel installation and should be clearly marked, in close proximity to the recorder and easily accessible to the operator.

All connections to the recorder are made to the Rear Terminal Panel. Any wiring carrying hazardous voltages must conform to all applicable local and national safety codes. AC Mains connection is via an internationally accepted IEC 320 AC mains connector or screw terminal (Figure 3-5 and Figure 3-6).

Figure 3-5

Figure 3-6

Figure 3-7

WARNING Ensure all mains power is turned off before proceeding with installation. This unit is provided with a mating connector for the ac power socket or with a compatible three wire grounded cable which may be terminated with a plug. Always ensure the ground wire (green or green and yellow) or ground pin of the plug, is connected to a low impedance safety ground (earth) within the ac power distribution system you are using. Always use the recommended mating connector and an approved three wire cable to connect this unit to the ac mains. Always provide a low impedance safety ground wire to the ground lug on the rear panel marked.

Figure 3-5 shows the IEC 320 AC mains connector on the rear of the recorder. The center pin is the ground termination. If a mating plug is provided, it will be marked with the Ground, LINE (L) or hot, and NEUTRAL (N) or return. In the United States, an approved cable with integral plug (NEMA 5-15 P) is provided. In some instances, a cable with no plug may be provided. In this instance, the user must connect an approved plug to the cable prior to connecting to the AC source.

Figure 3-6 shows the screw terminal power connections on the rear of the recorder. The right terminal is ground, the center terminal is LINE (L) or hot and the left terminal is NEUTRAL (N) or return. The wire color codes are as follows:

Figure 3-7 shows the ground lug on the rear panel. This screw terminal must be connected to an earth wire which in turn is connected to the ground or earth of the AC power distribution system.

This unit is equipped with an AC mains fuse internally. If this fuse should blow, it generally indicates a serious problem with the recorder. THE FUSE SHOULD NOT BE REPLACED BY AN OPERATOR. The fuse is a quick acting 5 x 20mm type - 2.0 Amps 250 VAC (~).

Page 17

09/11/2008 REV 0.99

Image 26
Contents User’s Guide Servicing North America Table of Contents Display Elements Environment and Location InstallationWiring Specifications and Procedures Browsing Historic Data Timer/Totalizer Reset Special EventsTurning the unit off Annotating Trends Browsing AnnotationsSystem Administrative Menu AlarmsRecord Setup Digital Input/OutputUSB Connections Utility Programs Touch Screen Cleaning Instructions CalibrationWorld Wide Web Web Based FTP Manager Ethernet Protocols 102Symbols Trademarks09/11/2008 REV Overview General DescriptionSystem Overview System Overview09/11/2008 REV Recorder Front Display AreaIR Comm Port Status IndicatorMedia Door StylusAnalog Inputs Power SupplyRecorder Rear Panel Input/Output Module Computer InterfaceConfiguration Files FilesActivity Files Exhibitor SoftwareData Files Miscellaneous FilesQuick Start Guide Activity Lights KeyboardingHelp SecurityRemote Access Passwords User LevelsEquipment Handling Environment and LocationInstallation Recorder Dimensions in Inches mmPanel Mounting Front Panel Cut OutPanel Front Gasket Rear View Panel InsertionPower Connections Wiring Specifications and ProceduresPower Requirements Signal Input Wiring Rear PanelThermocouple Inputs Resistance Temperature Detector RTD InputsAnalog Inputs Linear InputsPotential Free Contacts FrequencyEthernet Relay Output, Contact InputMouse and Keyboard Connection USB ConnectionAudio Connection 18 RS485 Adapter 19 RS485 120 Ohm Jumper 24Vdc Isolated Output OptionIsolated Serial Interface Option Task Bar Display ElementsLive Display Area Utility Setup Menu Utility Setup Menu09/11/2008 REV Folder Mydata Data File Mydata.dat Bitmap Files Text Files Alarm, Event and Activity LogsRecord Session Configuration Manager Load ConfigurationSending Email E-mail WindowDisplay Brightness User LoginDisplay Utilities Special Events Timer/Totalizer ResetRecord on Alarm Background ColorSystem Setup Email on Alarm EventRecord Setup Digital Input Setup Record Mode Alarm Master SetupAnnotating Trends Drawing on the ScreenBrowsing Historic Data Adding a Text MessageZoom and Compress Data 13.4 Zoom with point markersView Memos and Bitmaps Using the Cursor13.8 Cursor Mode 13.6 Memo View 13.7 Bitmap ViewUsing Browser Jump To Browsing AnnotationsInput Channels Master Channel SetupSetup display as shown right Channel Setup Channel SetupResistance Input Channel Type SetupLinear Input Industrial Square Root Extraction Thermocouples and RTDsCalculated Channel Setup Calculated Input09/11/2008 REV Gated Timer Conditional InputReset Point TotalizerFrequency/Pulse Count Frequency13 Pulse Count Setup Pulse CountRecorder Setup Display Builder Building the DisplayEditing 3 Display BuilderRotate List Digital Displays Digital Display SetupWidgets Will show OFFDisplaying Min, Max or Average Values Channel Type Shows the current widget style for Bar Graph SetupBar Graphs Channel. For information only09/11/2008 REV 09/11/2008 REV Trend Setup Trend Setup Window09/11/2008 REV Alarms RateAlarm Master Setup 1 Alarm Master SetupAlarm Setup Digital Input/Output Digital Output Setup 1 Digital Output SetupDigital Input Setup 09/11/2008 REV Record Setup Select ChannelsWhat to Record Media and FilenameRecord Rate Point type Max Min AverageTriggered Record Timed RecordSplit Files Media Alarm System Administrative Menu System Admin Menu09/11/2008 REV NTP Time Server Temperature CompensationSystem Setup Config Auto Save Modbus SettingsMouse Pointer Enable Menu TimeoutUser Setup Password Management UserFile Explorer Web User Manager Network Settings7 Web User Admin 6 Network IP Address9 USB ActiveSync Password Smtp Email SettingsSet ActiveSync Password Registry Languages System ReFlash09/11/2008 REV Communication World Wide Web3 View Recorder Web Based FTP Manager 2 FTP File Manager Communication Ethernet Protocols OPC ServerModbus Data Registers Modbus ServerModbus Status Registers Register # USB Connections Utility Programs FTP Manager09/11/2008 REV 09/11/2008 REV 3 Remote Recorder Remote ControlRemote Display 5 Remote Manager Connected Remote Manager4 Remote Manager Calibration Cleaning InstructionsTouch Screen Zero Cal Calibrating Linear Voltage InputsSet Channel Full CalCalibrating Frequency Store CalCalibrating the RTD Current Source Go to Table of Contents Power Requirements Resolution ColorVirtual Chart Speed Power Fail ProtectionType Range C Accuracy C Range F Accuracy F Weight SafetyDimensions Recording RatesAppendix B Digital Input Voltage Adjustment Input Board Fig B-4 Digital IO Module Jumpers 2 Channel shownWARRANTY/DISCLAIMER Temperature

RD8300 specifications

The Omega Speaker Systems RD8300 is a remarkable entry in the audio equipment market, designed for audiophiles and casual listeners alike who seek high-quality sound reproduction. This speaker system combines cutting-edge technologies with user-friendly features to deliver an immersive listening experience.

One of the standout characteristics of the RD8300 is its advanced driver configuration. Featuring a dual 8-inch woofers, a precision-tuned midrange driver, and a high-frequency tweeter, the RD8300 is engineered to provide a full range of frequencies with unparalleled clarity. This configuration ensures that bass notes are deep and powerful, while mid-range and treble sounds are crisp and detailed, making it suitable for a wide variety of music genres and audio formats.

Another integral technology in the RD8300 is its sophisticated crossover network. By intelligently directing frequencies to the appropriate drivers, the crossover helps to minimize distortion and enhance the overall sonic coherence of the speaker. This ensures every note is delivered with precision, allowing listeners to appreciate the nuances in their favorite tracks.

The RD8300 also boasts an impressive power handling capability, allowing it to deliver loud and dynamic sound without compromising audio quality. Its robust construction ensures minimal resonance, further enhancing sound clarity. The speaker's enclosure is crafted from high-density fiberboard, designed to reduce unwanted vibrations while maximizing audio performance.

In terms of connectivity, the RD8300 is versatile. It comes equipped with standard binding post inputs, making it compatible with a wide range of audio equipment. Additionally, it features both wired and wireless connectivity options, catering to modern listening preferences.

User convenience is another focus of the RD8300's design, with features such as adjustable feet and a user-friendly interface that allows for easy setup and adjustment. The sleek visual design of the speaker adds an aesthetic touch, making it an attractive addition to any room.

In summary, the Omega Speaker Systems RD8300 stands out as an exceptional speaker choice. With its advanced driver design, sophisticated crossover technology, impressive power handling, versatile connectivity options, and user-friendly features, it caters to those seeking a superior audio experience, making it a must-have for audio enthusiasts.