Omega Speaker Systems RD8300 manual Zoom and Compress Data, Zoom with point markers

Page 44
Figure 4-13.3 Trace Setup

Section 4 – Functional Description

Markers Off – Tapping this icon will remove the markers from the traces. This icon will only be visible if the markers are currently on.

Cursor – Tapping this icon turns on the cursor which allows unique identification of the points.

Go – Proceed to the (next) drop down dialog (memo options are memo, time, below.

instance of the „jump to” in Figure 4-13.3). Jump Ymax and Y min. See

Go from Start – Start at the beginning of data (most recent) and proceed to the next instance of the „jump

to” drop down dialog (memo in Figure 4-13.3)

Trace Setup – Tapping this icon will bring up the Trace Setup screen (see Figure 4-13.3), which enables the user to shut off traces on the display. Those

traces not on the original trend will be grayed out. Check the box next to the trace you want displayed, uncheck it to remove the trace from the browse trend. Traces can be turned on or off at any time.

Slider Bar – The Slider Bar is used to scroll back and forth through the data buffer. Sliding to the left brings up older data, sliding to the right brings up newer data. To move, press the slider with the stylus (or finger) and drag, or tap the bar to the left or right of the slider.

Exit - Returns to live data.

Note: The browser will always be in the form of a horizontal trend even if the live trend is vertical.

When in the browser, double-tapping the trend display area will take you to the Annotate Dialog window. Here the user can markup the current view and save it or print it. This permits annotating historic data which may have been missed on the live trend.

4.13.1 Zoom and Compress Data

Using the Zoom % drop down menu the user can select to zoom (numbers > 100) or compress (numbers <100) the time axis of data on the screen. Simply select the zoom value and the trend display will recalculate and display the compressed or zoomed data. 100% Zoom is the normal

representation on the trend. It may take some time to recalculate the view depending on the zoom level.

Figure 4-13.4 below, shows data zoomed 5 times with the point markers turned on. Figure 4-13.5 shows data compressed 5 times without point markers. The slider bar will navigate through the data at the zoom level selected.

Figure 4-13.4 Zoom with point markers

Figure 4-13.5 Compress no point markers.

Page 35

09/11/2008 REV 0.99

Image 44
Contents User’s Guide Servicing North America Table of Contents Display Elements Environment and Location InstallationWiring Specifications and Procedures Timer/Totalizer Reset Special Events Turning the unit off Annotating TrendsBrowsing Historic Data Browsing AnnotationsAlarms Record SetupSystem Administrative Menu Digital Input/OutputTouch Screen Cleaning Instructions Calibration World Wide Web Web Based FTP Manager Ethernet ProtocolsUSB Connections Utility Programs 102Symbols Trademarks09/11/2008 REV Overview General DescriptionSystem Overview System Overview09/11/2008 REV Recorder Front Display AreaStatus Indicator Media DoorIR Comm Port StylusAnalog Inputs Power SupplyRecorder Rear Panel Input/Output Module Computer InterfaceConfiguration Files FilesExhibitor Software Data FilesActivity Files Miscellaneous FilesQuick Start Guide Keyboarding HelpActivity Lights SecurityRemote Access Passwords User LevelsEquipment Handling Environment and LocationInstallation Recorder Dimensions in Inches mmPanel Mounting Front Panel Cut OutPanel Front Gasket Rear View Panel InsertionPower Connections Wiring Specifications and ProceduresPower Requirements Signal Input Wiring Rear PanelResistance Temperature Detector RTD Inputs Analog InputsThermocouple Inputs Linear InputsPotential Free Contacts FrequencyEthernet Relay Output, Contact InputMouse and Keyboard Connection USB ConnectionAudio Connection 18 RS485 Adapter 19 RS485 120 Ohm Jumper 24Vdc Isolated Output OptionIsolated Serial Interface Option Task Bar Display ElementsLive Display Area Utility Setup Menu Utility Setup Menu09/11/2008 REV Folder Mydata Data File Mydata.dat Bitmap Files Text Files Alarm, Event and Activity LogsRecord Session Configuration Manager Load ConfigurationSending Email E-mail WindowDisplay Brightness User LoginDisplay Utilities Timer/Totalizer Reset Record on AlarmSpecial Events Background ColorEmail on Alarm Event Record Setup Digital Input Setup Record ModeSystem Setup Alarm Master SetupAnnotating Trends Drawing on the ScreenBrowsing Historic Data Adding a Text MessageZoom and Compress Data 13.4 Zoom with point markersUsing the Cursor 13.8 Cursor ModeView Memos and Bitmaps 13.6 Memo View 13.7 Bitmap ViewUsing Browser Jump To Browsing AnnotationsInput Channels Master Channel SetupSetup display as shown right Channel Setup Channel SetupResistance Input Channel Type SetupLinear Input Industrial Square Root Extraction Thermocouples and RTDsCalculated Channel Setup Calculated Input09/11/2008 REV Gated Timer Conditional InputReset Point TotalizerFrequency/Pulse Count Frequency13 Pulse Count Setup Pulse CountRecorder Setup Display Builder Building the DisplayEditing 3 Display BuilderRotate List Digital Display Setup WidgetsDigital Displays Will show OFFDisplaying Min, Max or Average Values Bar Graph Setup Bar GraphsChannel Type Shows the current widget style for Channel. For information only09/11/2008 REV 09/11/2008 REV Trend Setup Trend Setup Window09/11/2008 REV Alarms RateAlarm Master Setup 1 Alarm Master SetupAlarm Setup Digital Input/Output Digital Output Setup 1 Digital Output SetupDigital Input Setup 09/11/2008 REV Record Setup Select ChannelsMedia and Filename Record RateWhat to Record Point type Max Min AverageTriggered Record Timed RecordSplit Files Media Alarm System Administrative Menu System Admin Menu09/11/2008 REV NTP Time Server Temperature CompensationSystem Setup Modbus Settings Mouse Pointer EnableConfig Auto Save Menu TimeoutUser Setup Password Management UserFile Explorer Network Settings 7 Web User AdminWeb User Manager 6 Network IP Address9 USB ActiveSync Password Smtp Email SettingsSet ActiveSync Password Registry Languages System ReFlash09/11/2008 REV Communication World Wide Web3 View Recorder Web Based FTP Manager 2 FTP File Manager Communication Ethernet Protocols OPC ServerModbus Data Registers Modbus ServerModbus Status Registers Register # USB Connections Utility Programs FTP Manager09/11/2008 REV 09/11/2008 REV 3 Remote Recorder Remote ControlRemote Display 5 Remote Manager Connected Remote Manager4 Remote Manager Calibration Cleaning InstructionsTouch Screen Calibrating Linear Voltage Inputs Set ChannelZero Cal Full CalCalibrating Frequency Store CalCalibrating the RTD Current Source Go to Table of Contents Resolution Color Virtual Chart SpeedPower Requirements Power Fail ProtectionType Range C Accuracy C Range F Accuracy F Safety DimensionsWeight Recording RatesAppendix B Digital Input Voltage Adjustment Input Board Fig B-4 Digital IO Module Jumpers 2 Channel shownWARRANTY/DISCLAIMER Temperature

RD8300 specifications

The Omega Speaker Systems RD8300 is a remarkable entry in the audio equipment market, designed for audiophiles and casual listeners alike who seek high-quality sound reproduction. This speaker system combines cutting-edge technologies with user-friendly features to deliver an immersive listening experience.

One of the standout characteristics of the RD8300 is its advanced driver configuration. Featuring a dual 8-inch woofers, a precision-tuned midrange driver, and a high-frequency tweeter, the RD8300 is engineered to provide a full range of frequencies with unparalleled clarity. This configuration ensures that bass notes are deep and powerful, while mid-range and treble sounds are crisp and detailed, making it suitable for a wide variety of music genres and audio formats.

Another integral technology in the RD8300 is its sophisticated crossover network. By intelligently directing frequencies to the appropriate drivers, the crossover helps to minimize distortion and enhance the overall sonic coherence of the speaker. This ensures every note is delivered with precision, allowing listeners to appreciate the nuances in their favorite tracks.

The RD8300 also boasts an impressive power handling capability, allowing it to deliver loud and dynamic sound without compromising audio quality. Its robust construction ensures minimal resonance, further enhancing sound clarity. The speaker's enclosure is crafted from high-density fiberboard, designed to reduce unwanted vibrations while maximizing audio performance.

In terms of connectivity, the RD8300 is versatile. It comes equipped with standard binding post inputs, making it compatible with a wide range of audio equipment. Additionally, it features both wired and wireless connectivity options, catering to modern listening preferences.

User convenience is another focus of the RD8300's design, with features such as adjustable feet and a user-friendly interface that allows for easy setup and adjustment. The sleek visual design of the speaker adds an aesthetic touch, making it an attractive addition to any room.

In summary, the Omega Speaker Systems RD8300 stands out as an exceptional speaker choice. With its advanced driver design, sophisticated crossover technology, impressive power handling, versatile connectivity options, and user-friendly features, it caters to those seeking a superior audio experience, making it a must-have for audio enthusiasts.