Section 5 – Recorder Setup

5.1.3.5Calculated Input

Any of the eighteen channels can be a calculated channel. A calculated channel gets its value from a series of calculations, which may be based on one or more live channels. Setting a live input channel to be a calculated channel will disable the live input. It is recommended that the virtual channels (Channel 7 to 18 in a 6 input unit or Channels 13 to 18 in a 12 channel unit) be assigned as calculated channels.

The Calculated Channel Setup dialog window has some powerful options. The user can set up 6 constants (X,Y,Z,I,J,K) to be used in the calculation and can define up to 6 functions (F1 to F6). The calculation can contain live inputs (C01 to C06 – Channels 1 to 6 for a 6 channel unit, or C01 to C12 – Channels 1 to 12 for a 12 channel unit), or other defined channels C01 to C18. The icons are defined as

Delete Button

Test Button

Constants: This allows the user to set a constant value, eg 3.41592 to a variable, say X, then use this in an equation by simply selecting the X. This is useful for coefficients and the like. To set the constant, check the Set Const. box, then touch any of the entry boxes to the right of the constant buttons. Use the numeric keys to enter the value. The ◄ and ► buttons will move the cursor, the Del button will delete the character to the left of the cursor and Clear button will erase all digits. When complete UNCHECK the Set Const. box. You can now use the constants by simply selecting the button. In the example shown right, pressing the X button will insert X into the equation, which is equivalent to 3.41592.

Clear Button

Exit Button

Figure 5-5 Calculated Channel Setup

Functions: This allows the user to define up to six functions for use in the calculations. To set up a function, check the Define box, then press the Function button, say F1. The input line will show F1=, continue to enter your formula using the available buttons. The ◄ and ► buttons will move the cursor, the Delete button will delete the character to the left of the cursor and Clear button will erase all digits. Once you have entered the function press the Enter button. (The Test button will change to Enter when you first select a Function key.) When you are done UNCHECK the Define box. You can now test your function or use it in the calculated channel.

Calculations: The calculations entered here will be assigned to the channel being set up. The calculations can use any of the 18 channels (C01 to C18), any of the six functions, any of the six constants, and the math functions. Make use of the parenthesis buttons to ensure your formula is interpreted correctly. The ◄ and ► buttons will move the cursor, the Del button will delete the character to the left of the cursor and Clear button will erase all digits. Once complete, it is necessary to test the function for accuracy by pushing the Test button. This will bring up the Test dialog as shown below. Once the calculation has been fully tested, press the Done button to return to the Calculated Channel Setup window and then press the Exit button.

Min, Max, Avg: The functions Min, Max and Avg use the MINimum, MAXimum or AVeraGe of a channel input in the calculation. The Average is a weighted average = (last value + current value)/2. The format is MAX(C02)+MIN(C03) for the maximum value of channel 2 plus the minimum value of channel 3. If Min, Max or Avg is used in an equation a reset dialog will appear upon exit. See below.

Page 42

09/11/2008 REV 0.99

Image 51
Contents User’s Guide Servicing North America Table of Contents Environment and Location Installation Wiring Specifications and ProceduresDisplay Elements Browsing Annotations Timer/Totalizer Reset Special EventsTurning the unit off Annotating Trends Browsing Historic DataDigital Input/Output AlarmsRecord Setup System Administrative Menu102 Touch Screen Cleaning Instructions CalibrationWorld Wide Web Web Based FTP Manager Ethernet Protocols USB Connections Utility ProgramsTrademarks Symbols09/11/2008 REV General Description OverviewSystem Overview System Overview09/11/2008 REV Display Area Recorder FrontStylus Status IndicatorMedia Door IR Comm PortPower Supply Recorder Rear PanelAnalog Inputs Computer Interface Input/Output ModuleFiles Configuration FilesMiscellaneous Files Exhibitor SoftwareData Files Activity FilesQuick Start Guide Security KeyboardingHelp Activity LightsUser Levels Remote Access PasswordsEnvironment and Location Equipment HandlingRecorder Dimensions in Inches mm InstallationFront Panel Cut Out Panel MountingRear View Panel Insertion Panel Front GasketWiring Specifications and Procedures Power RequirementsPower Connections Rear Panel Signal Input WiringLinear Inputs Resistance Temperature Detector RTD InputsAnalog Inputs Thermocouple InputsFrequency Potential Free ContactsRelay Output, Contact Input EthernetUSB Connection Audio ConnectionMouse and Keyboard Connection 24Vdc Isolated Output Option Isolated Serial Interface Option18 RS485 Adapter 19 RS485 120 Ohm Jumper Display Elements Live Display AreaTask Bar Utility Setup Menu Utility Setup Menu09/11/2008 REV Alarm, Event and Activity Logs Record SessionFolder Mydata Data File Mydata.dat Bitmap Files Text Files Load Configuration Configuration ManagerE-mail Window Sending EmailUser Login Display UtilitiesDisplay Brightness Background Color Timer/Totalizer ResetRecord on Alarm Special EventsAlarm Master Setup Email on Alarm EventRecord Setup Digital Input Setup Record Mode System SetupDrawing on the Screen Annotating TrendsAdding a Text Message Browsing Historic Data13.4 Zoom with point markers Zoom and Compress Data13.6 Memo View 13.7 Bitmap View Using the Cursor13.8 Cursor Mode View Memos and BitmapsBrowsing Annotations Using Browser Jump ToMaster Channel Setup Setup display as shown rightInput Channels Channel Setup Channel SetupChannel Type Setup Linear InputResistance Input Thermocouples and RTDs Industrial Square Root ExtractionCalculated Input Calculated Channel Setup09/11/2008 REV Conditional Input Gated TimerTotalizer Reset PointFrequency Frequency/Pulse CountPulse Count 13 Pulse Count SetupRecorder Setup Building the Display Display Builder3 Display Builder EditingRotate List Will show OFF Digital Display SetupWidgets Digital DisplaysDisplaying Min, Max or Average Values Channel. For information only Bar Graph SetupBar Graphs Channel Type Shows the current widget style for09/11/2008 REV 09/11/2008 REV Trend Setup Window Trend Setup09/11/2008 REV Rate Alarms1 Alarm Master Setup Alarm Master SetupAlarm Setup Digital Input/Output 1 Digital Output Setup Digital Output SetupDigital Input Setup 09/11/2008 REV Select Channels Record SetupPoint type Max Min Average Media and FilenameRecord Rate What to RecordTimed Record Split FilesTriggered Record Media Alarm System Admin Menu System Administrative Menu09/11/2008 REV Temperature Compensation System SetupNTP Time Server Menu Timeout Modbus SettingsMouse Pointer Enable Config Auto SaveUser User Setup Password ManagementFile Explorer 6 Network IP Address Network Settings7 Web User Admin Web User ManagerSmtp Email Settings Set ActiveSync Password9 USB ActiveSync Password Registry System ReFlash Languages09/11/2008 REV World Wide Web Communication3 View Recorder Web Based FTP Manager 2 FTP File Manager Communication OPC Server Ethernet ProtocolsModbus Server Modbus Status RegistersModbus Data Registers Register # USB Connections FTP Manager Utility Programs09/11/2008 REV 09/11/2008 REV Remote Control Remote Display3 Remote Recorder Remote Manager 4 Remote Manager5 Remote Manager Connected Cleaning Instructions Touch ScreenCalibration Full Cal Calibrating Linear Voltage InputsSet Channel Zero CalStore Cal Calibrating the RTD Current SourceCalibrating Frequency Go to Table of Contents Power Fail Protection Resolution ColorVirtual Chart Speed Power RequirementsType Range C Accuracy C Range F Accuracy F Recording Rates SafetyDimensions WeightAppendix B Digital Input Voltage Adjustment Fig B-4 Digital IO Module Jumpers 2 Channel shown Input BoardWARRANTY/DISCLAIMER Temperature