Omega Speaker Systems RD8300 manual Languages, System ReFlash

Page 88
Figure 5.7.11 – Language Screen

Section 5 – Recorder Setup

5.7.11 Languages

The languages option allows the users to customize the unit language for the local country by loading preconfigured language files. This

feature is entered from the system admin menu by pressing the icon shown right.

This will bring up the language dialog screen. NOTE:

Loading a new language will unload the existing configuration file.

Select the pull down menu to display a list of available languages. The recorder will check the internal memory for the language file. The user needs to load the language file “MultiLanguage.CSV” onto the root of the internal memory card. This is a spreadsheet style file with English in the first

column and alternative languages in subsequent columns. It is (and needs to be) in Comma Separated Variable format.

This language file can be edited using a standard spreadsheet editor such as ExcelTM and any language can be added following a simple set of rules – See Appendix C

Note: Save the file as .CSV and NOT .XLS format.

Select the language of choice and press the okay button.

The recorder will change to the new

language on the fly. The default language is English.

 

5.7.12 System ReFlash

This option allows the administrator to upgrade the system firmware. Once started this operation cannot be reversed. Choosing to proceed will require a system reset even if you cancel the operation.

DO NOT RESET the unit, DO NOT REMOVE POWER and DO NOT PRESS THE ABORT BUTTON while this operation is in process as it WILL MAKE THE UNIT INOPERABLE.

Before proceeding you need the image file that will be loaded. This file is called NK.bin and is available from your service center or can be downloaded from the web. Ensure that you need to update the firmware; often firmware upgrades will involve clearing the Registry, new configuration and language files. Read the text file that accompanies any firmware upgrade release. Load the file (NK.bin) onto removable media – compact flash drive or USB thumb drive, and insert this into the recorder before starting this procedure.

Select the reflash icon shown left from the System Admin Menu. Read and accept the warning notice shown right and proceed with caution.

You then need to accept or skip erasing the registry – this information will be in the release notes with the firmware. In some instances, failure to erase the registry will cause the unit to malfunction after reflash.

Page 79

09/11/2008 REV 0.99

Image 88
Contents User’s Guide Servicing North America Table of Contents Wiring Specifications and Procedures Environment and Location InstallationDisplay Elements Timer/Totalizer Reset Special Events Turning the unit off Annotating TrendsBrowsing Historic Data Browsing AnnotationsAlarms Record SetupSystem Administrative Menu Digital Input/OutputTouch Screen Cleaning Instructions Calibration World Wide Web Web Based FTP Manager Ethernet ProtocolsUSB Connections Utility Programs 102Symbols Trademarks09/11/2008 REV Overview General DescriptionSystem Overview System Overview09/11/2008 REV Recorder Front Display AreaStatus Indicator Media DoorIR Comm Port StylusRecorder Rear Panel Power SupplyAnalog Inputs Input/Output Module Computer InterfaceConfiguration Files FilesExhibitor Software Data FilesActivity Files Miscellaneous FilesQuick Start Guide Keyboarding HelpActivity Lights SecurityRemote Access Passwords User LevelsEquipment Handling Environment and LocationInstallation Recorder Dimensions in Inches mmPanel Mounting Front Panel Cut OutPanel Front Gasket Rear View Panel InsertionPower Requirements Wiring Specifications and ProceduresPower Connections Signal Input Wiring Rear PanelResistance Temperature Detector RTD Inputs Analog InputsThermocouple Inputs Linear InputsPotential Free Contacts FrequencyEthernet Relay Output, Contact InputAudio Connection USB ConnectionMouse and Keyboard Connection Isolated Serial Interface Option 24Vdc Isolated Output Option18 RS485 Adapter 19 RS485 120 Ohm Jumper Live Display Area Display ElementsTask Bar Utility Setup Menu Utility Setup Menu09/11/2008 REV Record Session Alarm, Event and Activity LogsFolder Mydata Data File Mydata.dat Bitmap Files Text Files Configuration Manager Load ConfigurationSending Email E-mail WindowDisplay Utilities User LoginDisplay Brightness Timer/Totalizer Reset Record on AlarmSpecial Events Background ColorEmail on Alarm Event Record Setup Digital Input Setup Record ModeSystem Setup Alarm Master SetupAnnotating Trends Drawing on the ScreenBrowsing Historic Data Adding a Text MessageZoom and Compress Data 13.4 Zoom with point markersUsing the Cursor 13.8 Cursor ModeView Memos and Bitmaps 13.6 Memo View 13.7 Bitmap ViewUsing Browser Jump To Browsing AnnotationsSetup display as shown right Master Channel SetupInput Channels Channel Setup Channel SetupLinear Input Channel Type SetupResistance Input Industrial Square Root Extraction Thermocouples and RTDsCalculated Channel Setup Calculated Input09/11/2008 REV Gated Timer Conditional InputReset Point TotalizerFrequency/Pulse Count Frequency13 Pulse Count Setup Pulse CountRecorder Setup Display Builder Building the DisplayEditing 3 Display BuilderRotate List Digital Display Setup WidgetsDigital Displays Will show OFFDisplaying Min, Max or Average Values Bar Graph Setup Bar GraphsChannel Type Shows the current widget style for Channel. For information only09/11/2008 REV 09/11/2008 REV Trend Setup Trend Setup Window09/11/2008 REV Alarms RateAlarm Master Setup 1 Alarm Master SetupAlarm Setup Digital Input/Output Digital Output Setup 1 Digital Output SetupDigital Input Setup 09/11/2008 REV Record Setup Select ChannelsMedia and Filename Record RateWhat to Record Point type Max Min AverageSplit Files Timed RecordTriggered Record Media Alarm System Administrative Menu System Admin Menu09/11/2008 REV System Setup Temperature CompensationNTP Time Server Modbus Settings Mouse Pointer EnableConfig Auto Save Menu TimeoutUser Setup Password Management UserFile Explorer Network Settings 7 Web User AdminWeb User Manager 6 Network IP AddressSet ActiveSync Password Smtp Email Settings9 USB ActiveSync Password Registry Languages System ReFlash09/11/2008 REV Communication World Wide Web3 View Recorder Web Based FTP Manager 2 FTP File Manager Communication Ethernet Protocols OPC ServerModbus Status Registers Modbus ServerModbus Data Registers Register # USB Connections Utility Programs FTP Manager09/11/2008 REV 09/11/2008 REV Remote Display Remote Control3 Remote Recorder 4 Remote Manager Remote Manager5 Remote Manager Connected Touch Screen Cleaning InstructionsCalibration Calibrating Linear Voltage Inputs Set ChannelZero Cal Full CalCalibrating the RTD Current Source Store CalCalibrating Frequency Go to Table of Contents Resolution Color Virtual Chart SpeedPower Requirements Power Fail ProtectionType Range C Accuracy C Range F Accuracy F Safety DimensionsWeight Recording RatesAppendix B Digital Input Voltage Adjustment Input Board Fig B-4 Digital IO Module Jumpers 2 Channel shownWARRANTY/DISCLAIMER Temperature

RD8300 specifications

The Omega Speaker Systems RD8300 is a remarkable entry in the audio equipment market, designed for audiophiles and casual listeners alike who seek high-quality sound reproduction. This speaker system combines cutting-edge technologies with user-friendly features to deliver an immersive listening experience.

One of the standout characteristics of the RD8300 is its advanced driver configuration. Featuring a dual 8-inch woofers, a precision-tuned midrange driver, and a high-frequency tweeter, the RD8300 is engineered to provide a full range of frequencies with unparalleled clarity. This configuration ensures that bass notes are deep and powerful, while mid-range and treble sounds are crisp and detailed, making it suitable for a wide variety of music genres and audio formats.

Another integral technology in the RD8300 is its sophisticated crossover network. By intelligently directing frequencies to the appropriate drivers, the crossover helps to minimize distortion and enhance the overall sonic coherence of the speaker. This ensures every note is delivered with precision, allowing listeners to appreciate the nuances in their favorite tracks.

The RD8300 also boasts an impressive power handling capability, allowing it to deliver loud and dynamic sound without compromising audio quality. Its robust construction ensures minimal resonance, further enhancing sound clarity. The speaker's enclosure is crafted from high-density fiberboard, designed to reduce unwanted vibrations while maximizing audio performance.

In terms of connectivity, the RD8300 is versatile. It comes equipped with standard binding post inputs, making it compatible with a wide range of audio equipment. Additionally, it features both wired and wireless connectivity options, catering to modern listening preferences.

User convenience is another focus of the RD8300's design, with features such as adjustable feet and a user-friendly interface that allows for easy setup and adjustment. The sleek visual design of the speaker adds an aesthetic touch, making it an attractive addition to any room.

In summary, the Omega Speaker Systems RD8300 stands out as an exceptional speaker choice. With its advanced driver design, sophisticated crossover technology, impressive power handling, versatile connectivity options, and user-friendly features, it caters to those seeking a superior audio experience, making it a must-have for audio enthusiasts.