Omega Speaker Systems RD8300 manual 09/11/2008 REV

Page 9

Warnings and Safety Precautions

WARNING AND SAFETY NOTICE

This Safety Notice has been included to emphasize the DANGER OF HAZARDOUS VOLTAGES on the REAR TERMINAL PANEL of your instrument. USE EXTREME CAUTION WHEN INSTALLING OR SERVICING your instrument. Please read the entire contents of Section 2 - Installation and Wiring within this manual before attempting to install or service your instrument.

1.Before any connections are made to the recorder, ensure the protective earth terminal is connected to a protective conductor.

WARNING

Any interruption of the protective conductor inside or outside the recorder, or disconnection of the protective earth terminal is likely to make the recorder dangerous under some fault conditions. Intentional interruption is prohibited.

NOTE: In order to comply with the requirements of safety standard EN61010, the recorder must have one of the following as a disconnecting device, located within easy reach of the operator, and be labeled as the disconnecting safety device:

A switch or circuit breaker which complies with the requirements of IEC 60947-1 and IEC 60947-3

A separable coupler which can be disconnected without the use of a tool

A separable plug, without a locking device, to mate with a socket outlet in the building

2.The protective earth terminal must remain connected (even if the recorder is isolated from the mains supply) if any of the measuring, communications, or relay terminals are connected to hazardous voltages.

3.Whenever it is likely that protection has been impaired, the recorder should be made inoperative and secured against operation. Contact the factory for assistance.

4.Any adjustment, maintenance and repair of the opened recorder under voltage should be avoided as far as possible and, if inevitable, should be carried out only by a skilled person who is aware of the hazard involved. All repairs should be carried out only by authorized service personnel or returned to an authorized repair center.

5.Where conductive pollution such as condensation or conductive dust is present, adequate air conditioning, filtering and/or sealing must be installed.

6.Signal and supply voltage wiring should be kept separate from one another. Where this is impractical, shielded cables should be used for the signal wiring.

7.If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment might be impaired or inadequate.

Page v

09/11/2008 REV 0.99

Image 9
Contents User’s Guide Servicing North America Table of Contents Environment and Location Installation Wiring Specifications and ProceduresDisplay Elements Turning the unit off Annotating Trends Timer/Totalizer Reset Special EventsBrowsing Historic Data Browsing AnnotationsRecord Setup AlarmsSystem Administrative Menu Digital Input/OutputWorld Wide Web Web Based FTP Manager Ethernet Protocols Touch Screen Cleaning Instructions CalibrationUSB Connections Utility Programs 102Trademarks Symbols09/11/2008 REV General Description OverviewSystem Overview System Overview09/11/2008 REV Display Area Recorder FrontMedia Door Status IndicatorIR Comm Port StylusPower Supply Recorder Rear PanelAnalog Inputs Computer Interface Input/Output ModuleFiles Configuration FilesData Files Exhibitor SoftwareActivity Files Miscellaneous FilesQuick Start Guide Help KeyboardingActivity Lights SecurityUser Levels Remote Access PasswordsEnvironment and Location Equipment HandlingRecorder Dimensions in Inches mm InstallationFront Panel Cut Out Panel MountingRear View Panel Insertion Panel Front GasketWiring Specifications and Procedures Power RequirementsPower Connections Rear Panel Signal Input WiringAnalog Inputs Resistance Temperature Detector RTD InputsThermocouple Inputs Linear InputsFrequency Potential Free ContactsRelay Output, Contact Input EthernetUSB Connection Audio ConnectionMouse and Keyboard Connection 24Vdc Isolated Output Option Isolated Serial Interface Option18 RS485 Adapter 19 RS485 120 Ohm Jumper Display Elements Live Display AreaTask Bar Utility Setup Menu Utility Setup Menu09/11/2008 REV Alarm, Event and Activity Logs Record SessionFolder Mydata Data File Mydata.dat Bitmap Files Text Files Load Configuration Configuration ManagerE-mail Window Sending EmailUser Login Display UtilitiesDisplay Brightness Record on Alarm Timer/Totalizer ResetSpecial Events Background ColorRecord Setup Digital Input Setup Record Mode Email on Alarm EventSystem Setup Alarm Master SetupDrawing on the Screen Annotating TrendsAdding a Text Message Browsing Historic Data13.4 Zoom with point markers Zoom and Compress Data13.8 Cursor Mode Using the CursorView Memos and Bitmaps 13.6 Memo View 13.7 Bitmap ViewBrowsing Annotations Using Browser Jump ToMaster Channel Setup Setup display as shown rightInput Channels Channel Setup Channel SetupChannel Type Setup Linear InputResistance Input Thermocouples and RTDs Industrial Square Root ExtractionCalculated Input Calculated Channel Setup09/11/2008 REV Conditional Input Gated TimerTotalizer Reset PointFrequency Frequency/Pulse CountPulse Count 13 Pulse Count SetupRecorder Setup Building the Display Display Builder3 Display Builder EditingRotate List Widgets Digital Display SetupDigital Displays Will show OFFDisplaying Min, Max or Average Values Bar Graphs Bar Graph SetupChannel Type Shows the current widget style for Channel. For information only09/11/2008 REV 09/11/2008 REV Trend Setup Window Trend Setup09/11/2008 REV Rate Alarms1 Alarm Master Setup Alarm Master SetupAlarm Setup Digital Input/Output 1 Digital Output Setup Digital Output SetupDigital Input Setup 09/11/2008 REV Select Channels Record SetupRecord Rate Media and FilenameWhat to Record Point type Max Min AverageTimed Record Split FilesTriggered Record Media Alarm System Admin Menu System Administrative Menu09/11/2008 REV Temperature Compensation System SetupNTP Time Server Mouse Pointer Enable Modbus SettingsConfig Auto Save Menu TimeoutUser User Setup Password ManagementFile Explorer 7 Web User Admin Network SettingsWeb User Manager 6 Network IP AddressSmtp Email Settings Set ActiveSync Password9 USB ActiveSync Password Registry System ReFlash Languages09/11/2008 REV World Wide Web Communication3 View Recorder Web Based FTP Manager 2 FTP File Manager Communication OPC Server Ethernet ProtocolsModbus Server Modbus Status RegistersModbus Data Registers Register # USB Connections FTP Manager Utility Programs09/11/2008 REV 09/11/2008 REV Remote Control Remote Display3 Remote Recorder Remote Manager 4 Remote Manager5 Remote Manager Connected Cleaning Instructions Touch ScreenCalibration Set Channel Calibrating Linear Voltage InputsZero Cal Full CalStore Cal Calibrating the RTD Current SourceCalibrating Frequency Go to Table of Contents Virtual Chart Speed Resolution ColorPower Requirements Power Fail ProtectionType Range C Accuracy C Range F Accuracy F Dimensions SafetyWeight Recording RatesAppendix B Digital Input Voltage Adjustment Fig B-4 Digital IO Module Jumpers 2 Channel shown Input BoardWARRANTY/DISCLAIMER Temperature

RD8300 specifications

The Omega Speaker Systems RD8300 is a remarkable entry in the audio equipment market, designed for audiophiles and casual listeners alike who seek high-quality sound reproduction. This speaker system combines cutting-edge technologies with user-friendly features to deliver an immersive listening experience.

One of the standout characteristics of the RD8300 is its advanced driver configuration. Featuring a dual 8-inch woofers, a precision-tuned midrange driver, and a high-frequency tweeter, the RD8300 is engineered to provide a full range of frequencies with unparalleled clarity. This configuration ensures that bass notes are deep and powerful, while mid-range and treble sounds are crisp and detailed, making it suitable for a wide variety of music genres and audio formats.

Another integral technology in the RD8300 is its sophisticated crossover network. By intelligently directing frequencies to the appropriate drivers, the crossover helps to minimize distortion and enhance the overall sonic coherence of the speaker. This ensures every note is delivered with precision, allowing listeners to appreciate the nuances in their favorite tracks.

The RD8300 also boasts an impressive power handling capability, allowing it to deliver loud and dynamic sound without compromising audio quality. Its robust construction ensures minimal resonance, further enhancing sound clarity. The speaker's enclosure is crafted from high-density fiberboard, designed to reduce unwanted vibrations while maximizing audio performance.

In terms of connectivity, the RD8300 is versatile. It comes equipped with standard binding post inputs, making it compatible with a wide range of audio equipment. Additionally, it features both wired and wireless connectivity options, catering to modern listening preferences.

User convenience is another focus of the RD8300's design, with features such as adjustable feet and a user-friendly interface that allows for easy setup and adjustment. The sleek visual design of the speaker adds an aesthetic touch, making it an attractive addition to any room.

In summary, the Omega Speaker Systems RD8300 stands out as an exceptional speaker choice. With its advanced driver design, sophisticated crossover technology, impressive power handling, versatile connectivity options, and user-friendly features, it caters to those seeking a superior audio experience, making it a must-have for audio enthusiasts.