Connect Span Ports to Director

To connect Director to the network using Span ports, be sure that at least one of your DNMs is a Span model. Use ports in that DNM to connect to the network.

Span port numbering is shown in the following diagram. It is the same for Span DNMs and in-line DNMs.

Port # n1.1 .2 .3

.4

.5 . 6

Port # n2.1 .2

.3 .4

.5 . 6

B

Span 10/100/1000

10

LINK

Span

 

 

 

 

 

 

 

 

 

 

 

100

ACT

GigaBit

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

Port # n1.7 .8 Port numbers in purple

.9

.10 .11 .12

Port # n2.7 .8

.9 .10 .11 .12

Figure 18: Port numbering for Span DNM models

Note:__________________________________________________________________________________________________

DNM 1 is on the left and DNM 2 is on the right. In the CLI, the Network ports are designated using the letter "n" followed by the DNM number, a dot, and then the port number. For example, the Network port on the upper left is n1.1 and the Network port on the lower right is n2.12.

________________________________________________________________________________________________________

To connect a Span port:

1.Plug the appropriate cable into a Director Span port.

2.Plug the other end of the cable into the Span port of the switch. The Link LED for the port illuminates after a short delay to indicate that a link has been established. If the traffic if flowing from the Span port, two Link LEDs blink.

Repeat for all desired Span port connections.

1 2 3 4 5

Director

2

1

6 7 8 9 10

www.netoptics.com

 

Spn

A

10/100/1000

B

A

B

10

LINK

Span

100

ACT

GigaBit

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 19: Span port connections

22

Image 26
Contents Data Monitoring Switch Trademarks and Copyrights Contents Appendix a Chapter Configuring Filters Using the CLIChapter Appendix BChapter Introduction Monitor port Filtering Key FeaturesEase of Use Passive, Secure TechnologyAbout this Guide DescriptionDirector Architecture Director internal architectureUSB port Director ManagementTypical Application Network LinksMonitoring Tools 10 Gigabit in-line network connection using a network Tap In-line Monitoring of 10 Gigabit LinksMonitor Port LEDs Power LEDsDirector Front Panel DNM / Network Port LEDsDirector Rear Panel XFPChapter Installing Director Plan the Installation Unpack and Inspect the Director deviceRack Mount the Director device Install Director Network ModulesInstall SFP and XFP Monitor port Modules Connect Power to Director Connect the local CLI InterfaceTip Connect the remote CLI InterfaceBaud Data bits No parity 1 stop bit No flow control To connect the CLI for remote use over the Management portLog into the CLI To log into the CLITo change the login password Configure Director using the CLIChange Director Password To assign a new Manager IP address to Director To change the port modeAssign a New Manager IP Address Change Port ModesSave and Load Director Configurations Set the Current Date and TimeUsing the CLI Help Command To view CLI help informationUsing the CLI Command History Buffer Show name show running, factory, default, or file nameConnect Span Ports to Director To connect a Span portConnect Director With In-line Network Links To connect an in-line network linkConnect Monitoring Tools to Director Configure a Matrix Switch connection in DirectorCheck the Installation Chapter Configuring Filters Using the CLI SyntaxEnter filter commit. The switch connection is activated Copy Traffic From Any Network Port to Any Monitor PortRegenerate Traffic to Any Set of Monitor Ports Lter add inports=n1.1 action=redir redirports=m.3-m.5Create Filters To create a filter that selects IPv4 packets by protocolCreate Complex Filters Logical and filter connectionView filters UDPWork with configurable 10 Gigabit ports Configurable 10 Gigabit XFP ports used as Network portsXFP Port Protocol = Monitor Port Understand filter interactions CAMFlow diagram now looks as follows Exclusive filters N1.1 ipproto=UDP action=drop N1.1 m.1To change the Director filter configuration Understand pending and active filtersFilter running command Enter filter list to view the pending filter list Filter capacity Inports=n1.1-n1.7 Ipproto=6 Vlan=100 Redirports=m.1-m.5,m.10Daisy-chaining Multiple Director Chassis Appendix a Director Specifications Specifications, chassisCertifications Specifications, DNMEnvironmental Available ModelsAppendix B Command Line Interface Command Sub-Command Arguments Example and description CommitFilter discard Image Quit User add name=bob pw=bob-pw priv=3 Filter parameters Director Filter Parameters Qual Value Example Description Vlan=128Appendix C Protocol Numbers Num Keyword ProtocolMobile L2TP Limitations on Warranty and Liability By Net Optics, Inc. All Rights Reserved