Net Optics manual Director Architecture, Director internal architecture

Page 8

Director

Director Architecture

The following diagram shows a schematic view of the architecture of the Director device shown as a Matrix Switch with filtering. The black dots indicate aggregating Matrix Switch connections between Network Ports and Monitor Ports.

DNM with 6 in-line network ports

DNM with 12 Span or out-of-band network ports

Four configurable 10GbE XFP ports

Key:

n1.1

n1.2

n1.3

n1.4

n1.5

n1.6

n1.7

n1.7

n1.9

n1.10

n1.11

n1.12

n2.1

 

 

n2.2

 

 

n2.3

 

 

n2.4

 

 

n2.5

 

 

n2.6

 

 

n2.7

 

 

n2.8

 

 

n2.9

 

 

n2.10

 

 

n2.11

 

 

n2.12

 

 

 

t1.1

 

 

 

t1.2

 

 

 

t2.1

 

 

 

t2.2

 

 

Filters t1.1 t1.2 t2.1 t2.2 m.1 m.2 m.3 m.4 m.5 m.6 m.7 m.8 m.9 m.10

 

Network or Span port

10 SFP monitor ports

 

Monitor Port

 

 

 

 

Aggregating switch conection

 

Dim Alternate configurations for 10 GbE XFP ports

 

Figure 1: Director internal architecture

Director can be viewed as a matrix switch with up to 28 inputs, or Network ports, and 14 outputs, or Monitor ports. Any number of inputs can be directed to each of the outputs; Director aggregates the traffic from those Network ports and sends them to the Monitor ports. For example, the diagram shows:

Traffic from the first in-line Network link (n1.1-n1.2) is being directed to the first SFP Monitor port (m.1)

Traffic from two in-line Network links (n1.3-n1.4 and n1.7-n1.8) plus three Span Network ports (n2.3, n2.7, and n2.11) is being aggregated and directed to the second SFP Monitor port (m.2)

Traffic from one in-line Network link (n1.11-n1.12) is being regenerated to two SFP Monitor ports (m.9 and m.10)

The traffic from the in-line Network links to the Monitor ports may include the traffic being received at the odd- numbered Network port (at the left side of the diagram), at the even-numbered Network port (at the right side of the diagram), or both; the diagram doesn't include this level of detail.

In addition, filters (shown at the bottom of the diagram) are configured independently for each Monitor port, one or more filters per port, and applied on the aggregated traffic for that port. For example, the second SFP Monitor port could have two filters, where one filter selects the TCP traffic from the two in-line Network links and the second filter selects the UDP traffic from the three Span Network ports.

4

Image 8
Contents Data Monitoring Switch Trademarks and Copyrights Contents Chapter Configuring Filters Using the CLI ChapterAppendix a Appendix BChapter Introduction Key Features Ease of UseMonitor port Filtering Passive, Secure TechnologyAbout this Guide DescriptionDirector Architecture Director internal architectureUSB port Director ManagementTypical Application Network LinksMonitoring Tools 10 Gigabit in-line network connection using a network Tap In-line Monitoring of 10 Gigabit LinksPower LEDs Director Front PanelMonitor Port LEDs DNM / Network Port LEDsDirector Rear Panel XFPChapter Installing Director Plan the Installation Unpack and Inspect the Director deviceRack Mount the Director device Install Director Network ModulesInstall SFP and XFP Monitor port Modules Connect Power to Director Connect the local CLI InterfaceConnect the remote CLI Interface Baud Data bits No parity 1 stop bit No flow controlTip To connect the CLI for remote use over the Management portLog into the CLI To log into the CLITo change the login password Configure Director using the CLIChange Director Password To change the port mode Assign a New Manager IP AddressTo assign a new Manager IP address to Director Change Port ModesSave and Load Director Configurations Set the Current Date and TimeUsing the CLI Help Command To view CLI help informationUsing the CLI Command History Buffer Show name show running, factory, default, or file nameConnect Span Ports to Director To connect a Span portConnect Director With In-line Network Links To connect an in-line network linkConnect Monitoring Tools to Director Configure a Matrix Switch connection in DirectorCheck the Installation Chapter Configuring Filters Using the CLI SyntaxEnter filter commit. The switch connection is activated Copy Traffic From Any Network Port to Any Monitor PortRegenerate Traffic to Any Set of Monitor Ports Lter add inports=n1.1 action=redir redirports=m.3-m.5Create Filters To create a filter that selects IPv4 packets by protocolCreate Complex Filters Logical and filter connectionView filters UDPWork with configurable 10 Gigabit ports Configurable 10 Gigabit XFP ports used as Network portsXFP Port Protocol = Monitor Port Understand filter interactions CAMFlow diagram now looks as follows Exclusive filters N1.1 ipproto=UDP action=drop N1.1 m.1To change the Director filter configuration Understand pending and active filtersFilter running command Enter filter list to view the pending filter list Filter capacity Inports=n1.1-n1.7 Ipproto=6 Vlan=100 Redirports=m.1-m.5,m.10Daisy-chaining Multiple Director Chassis Appendix a Director Specifications Specifications, chassisSpecifications, DNM EnvironmentalCertifications Available ModelsAppendix B Command Line Interface Command Sub-Command Arguments Example and description CommitFilter discard Image Quit User add name=bob pw=bob-pw priv=3 Filter parameters Director Filter Parameters Qual Value Example Description Vlan=128Appendix C Protocol Numbers Num Keyword ProtocolMobile L2TP Limitations on Warranty and Liability By Net Optics, Inc. All Rights Reserved