Multi-Tech Systems MT5634ZBA-DID manual Other Commands, Quick Connect Control

Page 30

MultiModemDID User Guide

Chapter 4 - AT Commands, S-Registers, Result Codes

 

 

Command: +PQC=n

Quick Connect Control

Values:

n = 0, 1, 2, or 3

Default:

3

Description:

Controls the V.92 shortened Phase 1 and Phase 2 startup

 

procedures (Quick Connect). When line conditions are stable,

 

quick connect results in shortened connect times; however,

 

significant fluctuation in line conditions from call to call can result in

 

longer connect times, in which case it may be advisable to

 

disable quick connect.

+PQC=0

Enables Short Phase 1 and Short Phase 2 (Quick Connect)

+PQC=1

Enables Short Phase 1

+PQC=2

Enables Short Phase 2

+PQC=3

Disables Short Phase 1 and Short Phase 2

+PQC=?

Displays the allowed values

+PQC?

Displays the current value

Other Commands

Command: +VCID=n Caller ID Selection

Values:

n = 0, 1, or 2

Default:

0

Description:

Enables Caller ID detection and configures the reporting and

 

presentation of the Caller ID data that is detected after the first

 

ring. The reported data includes the date and time of the call,

 

the caller's name and number, and a message. Set S0=2.

+VCID=0

Disables Caller ID

+VCID=1

Enables Caller ID with formatted data

+VCID=2

Enables Caller ID with unformatted data

+VCID=?

Displays the allowed values

+VCID?

Displays the current value

Command: +VDR=x, y Distinctive Ring Report

Values:

x = 0, 1 Distinctive Ring report control.

 

y = 0–255Minimum ring interval in 100 ms units.

Default:

0, 0

Description:

Enables reporting of ring cadence information to the DTE and

 

specifies the minimum ring cadence that will be reported.

 

The report format is one line per silence period and one line per

 

ring period. The length of the silence period is in the form

 

DROF=number in units of 100 ms<CR><LF>, and the length of

 

the ring is in the form DRON=number in units of 100 ms<CR>

 

<LF>. The modem may produce a Ring event code after the

 

DRON message if enabled by the y parameter. The y parameter

 

must be set to a value equal to or smaller than the expected

 

ring cadence in order to pass the report to the DTE.

+VDR=0, n/a

Disables Distinctive Ring cadence reporting.

+VDR=1, 0

Enables Distinctive Ring cadence reporting. Other call progress

 

result codes (including RING) are reported as normal.

+VDR=1, >0

Enables Distinctive Ring cadence reporting. The RING result

 

code is reported after the falling edge of the ring pulse (i.e., after

 

the DRON report).

+VDR=?

Displays the allowed values.

+VDR?

Displays the current value.

30

Image 30
Contents User Guide Trademarks Record of RevisionsRevision Date Description PatentsTable of Contents MultiModemDID User Guide Contents Features Introduction and DescriptionIntroduction Safety We SupplyYou Supply Installation Assemble the ModemConnect the Modem to Your System Connect the Modem to the AC Power Outlet Removing Your Old Modem from WindowsFrom Windows 2000, XP Operation Front Panel of the MultiModemDID ModemDid Operation OperationConnecting to the Internet Dial-Up NetworkingAT Commands, S -Registers Result Codes Communication Standard Setting AT CommandsRepeat Last Command AnswerDS=n Dial Stored Telephone Number Echo Command Mode CharactersNumber ATDT1028806127853500$123456789 Echo Online Data CharactersResult Codes Enable/Disable Monitor Speaker ModeReturn Online to Data Mode Modulation HandshakeResult Code Format Modem ResetTone Dialing Result Code OptionsData Terminal Ready DTR Control Load Factory SettingsAsynchronous Communications Mode XON/XOFF Pacing ControlStore Current Configuration Test CommandsDisplay Current Settings Store Dialing CommandOnline command mode. The modem receives a \Bn \Bn Transmit Break\Kn Break Control \Qn Flow Control Selection \Nn Error Correction Mode Selection\Tn Inactivity Timer \Vn Protocol Result CodeDirect Connect Enable Adaptive Answer Result Code EnableDC n AT Command Control View Numbers in BlacklistCommand +DCS=x,y Select V.44 Data Compression Cisco ConfigurationCommand Speed Response $Dn DTR DialingCommand +DS44=n V.44 Data Compression Data Compression ReportingEnable Synchronous Buffered Mode Modulation Selection SubparametersMod value Valid max-rate values bps Modem on Hold Enable CommandsCommand +PCW=n Call Waiting Enable PCM Upstream IgnoreCommand +PMHR=n Modem on Hold Initiate Command +PMHT=n Modem on Hold TimerCommand +VDR= x, y Distinctive Ring Report Other CommandsCommand +VCID=n Caller ID Selection Quick Connect ControlCommand +++ATCR Escape Sequence Command %%%ATCR Remote Configuration Escape SequenceMT5634ZBA-DID Initialization Recommendations Number of did Digits Expected Busy-Out Timer at End of CallWait for Digit Time-Out Time Digit FormatDF1 Format for Reporting Incoming did NumberDF0 DF2Page Register Unit Range Default Description RegistersValue Speed Value RateS42 Value Digital lossCarrier signal lost or not detected Command executedRing signal detected Invalid commandPage Remote Configuration Basic ProcedureSetup Changing the Remote Escape Character Troubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Dials But Cannot Connect Modem Doesn’t Work with Caller ID Modem Cannot Connect When AnsweringModem Disconnects While Online Fax and Data Software Can’t Run at the Same TimeDid Troubleshooting Appendix a Regulatory Compliance FCC Part 68 TelecomCanadian Limitations Notice FCC PartFax Branding Statement Industry CanadaAppendix B Technical Specifications FaxUpgrade Overview Appendix C Upgrading the Modem’s FirmwareExtract the Upgrade Files Select Dialup Configuration Tool Appendix D Installing a Modem Under LinuxInstallation Standard Linux Serial Port DefinitionsCalling the ISP Select RH PPP DialerSymbols IndexMultiModemDID User Guide Index MultiModemDID User Guide Index