N-Tron 102PC-SE user manual Recv-mail Configure incoming mail options

Page 15

o

recv-mail

(Configure incoming mail options)

 

￿

leave-on-server

(enable or disable to leave messages on the server)

 

￿

mailbox-name

 

(set the mailbox’s name)

 

￿

mailbox-password

(set the mailbox’s password)

 

￿

server-name

 

(set the server’s name)

 

￿

server-port

 

(set the server’s port number)

o

send-mail

(Configure outgoing mail options)

￿smtp-server-name

￿smtp-server-port

￿host-name

￿from-address

￿from-address-identity

￿to-address

￿cc-address

￿reply-to-address

￿subject

(set the smtp server name)

(set the smtp server port number) (set the host name)

(set the mail ID for the from address, ex. info@n-tron.com) (string associated with the mail ID, ex. N-Tron)

(set the to mail address field) (set the cc mail address field) (set the mail ID reply to address) (set the subject field of the message)

o serial

(Configure the serial settings for the serial port s0)

￿

auto-dialin

(enable or disable auto-dialin)

￿

escape-monitor

(enable or disable escape monitor)

￿

escape-string

(set the escape string, default ‘+++inet’)

￿

s0

(configuration options for serial port s0)

 

auto-dialin

(configure auto dialin settings)

 

 

o

enable/disable

 

(enable or disable auto-dialin)

 

 

o

message

 

(enable or disable auto-dialin message)

 

o

trig-mode

 

(char, dtr, dtr-char, or none trig mode options)

 

auto-dialin-ipaddress

(set an IP address for the auto-dialin feature)

 

auto-dialin-port

(set the port number for the auto-dialin feature)

 

auto-dialin-protocol

(telnet)

 

 

auto-dialout

(enable or disable auto dialout)

 

auto-dialout-port

(set the port number for the auto-dialout feature)

 

auto-dialout-protocol

(telnet)

 

 

baud-rate

 

(Possible baud-rate value(s) are 300 600 1200 1800 2400 4800 9600 19200 38400 57600

 

 

 

 

115200 230400)

 

buffer-datasize

(Buffer data-size range: [1-1500] bytes)

 

buffer-time

(set a buffer time in seconds, 0 for no buffer)

 

chat-script

(Chat-script is used to establish physical link from the dialing to answering end in case of

 

 

 

 

modem connect, when modem dialing-method is set to chat-script.)

 

connect-state

(answering or dialing state)

 

connect-type

(direct or modem connect type)

 

data-bits

 

(set the number of data-bits over the serial line, default is 8 bits)

 

dialout-monitor

(set the dialout monitor to dtr or none)

 

echo-command

(enable or disable the echo command)

 

flow-control

(rts-cts or none)

 

host-interaction-mode

(enable or disable host interaction mode)

 

login-string

(string up to 8 characters)

 

modem

 

(modem configuration)

 

 

o

connect-string

 

(set the connect string for a modem)

 

 

o

dial-number

 

(set the number to dial)

 

 

o

dial-prefix

 

(any prefix dialing needed can be set here)

 

 

o

dial-suffix

 

(any suffix dialing needed can be set here)

 

 

o

dialing-method

(use configuration of chat-script)

 

 

o

hangup-string

 

(set string used to hang up the line)

 

 

o

init-string

 

(set init number [1-5])

 

 

o

ok-string

 

(set an ok string)

 

o

ring-string

 

(set a ring string)

 

parity

 

(none, odd, or even parity)

 

raw-dialin

(enable or disable raw-dialin)

 

raw-dialout

(enable or disable raw-dialout)

 

stop-bits

 

(set the number of stop bits [1, 1.5, or 2])

o

time

(Set system time HH:MM:SS)

o

watchdog

(Enable or disable watchdog)

(continued…)

12/1/2006

15

Image 15
Contents 12/1/2006 Table of Contents 12/1/2006 Contact Information Safety WarningsEnvironmental Safety Electrical Safety Package Contents CleaningUnpacking DIN Rail Mounting ServicingColor Description Front PanelApplying Power Top View Grounding Techniques Connecting the Unit Serial Interface Serial CableRS-232 Support FCC Statement TroubleshootingCLI Tree of Menus Set Set configurable fields Recv-mail Configure incoming mail options Send-mail Configure outgoing mail optionsSerial Configure the serial settings for the serial port s0 Show Show general and detailed information Socket Actions to take over a UDP socket Web Management Software Configuration12/1/2006 Web Management Tree of Menus General ConfigurationUser Configuration Port ConfigurationChatscript Modem ConfigurationBridge Configuration PPP ConfigurationSuccessfully. These cannot be modified Telnet ConfigurationAutodial Configuration UDP ConfigurationPOP3 Configuration Http ConfigurationSnmp Configuration Smtp Address ConfigurationSntp General Sntp Daylight Saving ConfigurationCommands Restore DefaultsEthernet to Serial Connectivity Mandatory Configuration SettingsScenario 1 Manual Dialout Commands to Setup Manual Dial-out with the 102PC-SEPrerequisites Scenario 2 Auto Dialout Using TelnetAuto Dialout Feature using UDP Mode Scenario 3 Auto Dialout Using UDPScenario 4 Remote Bridging with Modem Connection # set ppp ppp0 raw-mode enableSerial to Ethernet Connectivity Scenario 1 Manual Serial Dial-in Commands to Setup Manual Dial-In with the 102PC-SEScenario 2 Serial Auto Dial-in Using Telnet Functionality Scenario 3 Serial Auto Dial-in Using UDPScenario 4 Serial Tunneling Mode # set ip telnet raw-mode enable# set serial s0 raw-dialout enable Using E-Mail Features Sending Text E-mails from the Command Prompt Receiving E-mails from the Command Prompt Physical KEY SpecificationsSwitch Properties Emissions and Safety ApprovalsTron Limited Warranty