MaxTech V.42bis, V.32bis user manual Q3

Page 30

\Bn

n=1-9

Send a 1/10 second line break to the modem,

 

 

where n = 1 to 9. At normal connect, the

 

 

default is 3

\C_

\C0

Do not buffer data during LAPM/MNP

 

 

handshaking

 

\C1

Buffer all data for 4 seconds, until receiving

 

 

200 characters or until a packet is detected

 

\C2

Do not buffer data; switch to normal mode

 

 

when fallback character is detected

\G_

\G0

Disable DCE flow control

 

\G1

Enable DCE flow control

\J_

J0

Disable serial port data rate adjustment

 

 

(keep high data rate between DTE and

 

 

modem, regardless of modem-to-modem

 

 

data rate)

 

J1

Enable serial port data rate adjustment so

 

 

serial data rate automatically adjusts to match

 

 

the modem-to-modem data rate

\Kn

n=0-5

Set break control, where n= 0 to 5. Default

 

 

is 5

\N_

\N0

Normal data-link only

 

\N1

Direct data-link only

 

\N2

MNP data link only

 

\N3

V.42/MNP/Normal data link

 

\N4

V.42 data link only

\O

 

Initiate reliable link during a normal link

\Q_

\Q0

Turn off flow control

 

\Q1

XON/XOFF software flow control

 

\Q2

CTS signal unidirectional hardware flow

 

 

control

 

\Q3

RTS/CTS signal bi-directional hardware

 

 

flow control

\Tn

 

Inactivity timer, where n = 0 to 90 minutes.

 

 

Default is 0

\U

 

Accept reliable link during a normal link

\V_

\V0

Do not send extended responses

 

\V1

Send extended response set 1

 

\V2

Send extended response set 2

\X_

\X0

Process XON/XOFF but don’t pass through

 

\X1

Process XON/XOFF and pass through

10

Image 30
Contents Contents Hardware Installation Unpacking Your ModemSoftware Installation/Configuration Fasten the retaining bracketPage COM Port and Interrupt Settings Devices in your computer cannot share an IRQ withTesting Your Modem After Installation Using Your ModemWhere To Go From Here Executing CommandsCommand Structure Basic AT Commands Extended AT Commands Force DSR Signal High on Mode after DTR toggleGuard tone disabled Enable Trellis Coding @Enable Auto Fall Forward/Back 22bis auto-retrain disabled22bis auto-retrain enabled Disable Auto Fall Forward/BackFax Class 1 Commands Voice Mode Commands S Registers Function Range/units Default Basic Response Codes Modem does not respond to commands Modem does not dialModem dials but does not connect Modem makes a connection but no data appears on your screen High pitch tone is heard whenever you answer the phoneModem exhibits poor voice record or playback FCC Compliance UartFCC Class B Statement DOC Compliance InformationDisclaimer, Copyright, And Other Notices Section One Introduction Software Installation/Configuration COM Port and Interrupt Settings Switch Block SW-1 Location Switch Block Settings Testing Your Modem After Installation Originate calls in answer mode Bold text Command Function Manually answer incoming callCcitt mode With AT or follow with EnterCommands are not echoed Toggle Resets modem after DTR toggleRecall factory default configuration Hz guard toneMNP/V.42/V.42bis Commands \A3\Q3 Switch to reliable link from normal link Register Function Range/units Default S RegistersSection Five Result Codes Section Six Troubleshooting Modem does not dial Power 75 W Section Eight Support and Service DOC Compliance Information Disclaimer, Copyright, And Other Notices