Liebert XDK user manual Important Safety Instructions

Page 2

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Liebert engineers will provide comprehensive support on how to install the XDK.

Extensive material, function and quality checks ensure that you fully benefit from product functions and a long service life. Nevertheless, this product can produce hazards if it is used incorrectly by untrained personnel or is not used for the correct purpose.

Read these operating instructions carefully before commissioning the XDK.

The electrical equipment complies with the applicable VDE and accident prevention regulations. Haz- ardous voltages (higher than 50 VAC or higher than 100 VDC) are present:

inside the electric box in the unit's housing

behind the fan cover on the outside of the rear door

Shut down the unit immediately if there are problems with electrical input or cold water supply.

! WARNING

Risk of electric shock. Can cause injury or death.

Disconnect all local and remote electric power supplies before working within.

Only qualified personnel may perform repair, maintenance, and cleaning operations.

NOTE

Cleaning and servicing must be performed by qualified personnel. To ensure that the unit remains safe to use and has a long service life, observe the maintenance and cleaning intervals.

Operate the XDK correctly within the stipulated ratings and with approved equipment. During all work on and with the unit, observe:

All applicable regulations (e. g., VDE regulations and other applicable national regulations)

All applicable accident prevention instructions (BGV)

All applicable laws on environmental protection

Operate the XDK only if it is in proper working condition. If a malfunction or fault occurs, you must shut down the unit immediately and notify the responsible facility official or employee.

Resume operating the unit only after the malfunction or fault has been rectified and the XDK’s func- tion has been re-established.

! CAUTION

Risk of contact with hot surfaces. Can cause burn injury.

Fans, power supplies, PC boards, and other components become extremely hot during unit operation. Allow sufficient time for them to cool before working within the unit.

Use extreme caution and wear protective gloves and arm protection when working on or near hot components.

Image 2
Contents UserManual-17kW Important Safety Instructions Table of Contents Figures Introduction General operating data Proper ApplicationOperating Conditions General function DescriptionHeat Exchanger Principle of Cooling OperationAir / Water XDK general data Technical dataData Overview-XDK Control Automatic Door OpeningFunction Initial CommissioningManual Closing Manual OpeningEquipment INSPECTION, Handling and Storage Packaging MaterialHandling Storage Returning the Unit in Case of DamagePositioning the XDK Preparation for InstallationInstallation and Commissioning Remove Recirculation Air Duct Transport LockWater Connection Preparing Heat Exchanger for Initial CommissioningTop View Rear Preparations for ConnectingCondensed Water Connection FrontElectrical Connection Sealing the CabinetGeneral Inspection on Fans-Annual Servicing and MaintenanceFan Replacement Reinstall the fan by reversing the steps to remove the fan Inspect the Heat Exchanger-AnnualHeat exchanger replacement Replacing the Heat ExchangerDismantling and Disposal Suggested hydrologic levels Water Purity RequirementsPrevalent impurities and removal methods Unit Installation Checklist XDK Commissioning certificate Nominal values at setup siteCommissioning Certificate Control of status ConfigurationType of cabinet Function check Cold water facility on siteElectrical data / documents GPM Water Purity Requirements Page Ti n Ne tIti That