Magnum 700X | Installation and User Guide (05/98) |
|
|
to provide connectivity to any media type.
The
The Magnum
The maximum transmission distance between a backbone transceiver equipped with an AUI connector and the Magnum
According to Ethernet standards, the maximum distance from the transceiver AUI connector and the attached device (Magnum
Important Note: The maximum transmission distance is decreased by 6m (20 ft.) for every additional level of network transceiver device "dropped" or "cascaded" from the original backbone transceiver tap.
The
| Table 2.3.2: AUI Pin Assignments | ||
Pin | Function | Pin | Function |
1 | Control In Circuit Shield | 10 | Data Out Circuit B |
2 | Control In Circuit A | 11 | Data Out Circuit Shield |
3 | Data Out Circuit A | 12 | Data In Circuit B |
4 | Data In Circuit Shield | 13 | Voltage Plus (+) |
5 | Data In Circuit A | 14 | Voltage Shield |
6 | Voltage Common | 15 | Control Out Circuit B |
7 | Control Out Circuit A | SHELL | Protective Ground |
8Control Out Circuit Shield (conductive shell)
9Control In Circuit B
NOTES: 1) Voltage Plus (pin #13) and Voltage Common (pin # 6) use a single twisted pair in the AUI cable.
2)Pins 4, 8, 11 and 14 may be connected to pin #1.
GARRETT