GarrettCom Magnum 700X manual Installing PM Cards, Installing the PM Card, Each PM card fits

Page 29

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

2.Remove PM Retaining Screws

On the front of the unit there are two retaining screws for each PM card slot. These screws are used to secure the face plate in position. These screws are also used to secure individual PM modules. (See Figure 3.3c).

Magnum 700X

Magnum 700X Chassis

PM

Retaining

Screws

Chassis

Base

Figure 3.3c: Front Panel View - PM Retaining Screws

Once the face plate or PM has been removed, proceed to Section 3.4 and install the PM

card.

3.4Installing PM Cards

Up to seven assorted PM (Port Module) cards are easily installed in the Magnum 700X Mini-Concentrator chassis. The installation procedure for PMs is described below.

1.Removing 700X Chassis Cover and PM Retaining Screws

Follow the procedure described for Face Plates in Section 3.3, Steps 1 and 2, above.

 

 

RPM Retaining

 

 

 

Screw Hole

 

2.

Installing the PM Card

- PM Media Interface

PM Mounting

 

 

Plate

 

Each PM card fits

- ST (Fiber)

 

 

- SMA (Fiber)

 

 

 

- BNC (ThinNet)

 

 

easily into any available

- AUI (ThickNet)

 

 

- RJ-45 (Twisted Pair)

Magnum

 

 

- DTE (RS-232)

PM Card

 

connector socket slot.

- SMF (Fiber)

 

 

 

 

 

 

Align the connector

 

 

 

pins on the PM card

PM

Eight (8) Pin

 

PM Conector

 

 

Retaining

 

 

with the connector

Screw Hole

 

 

 

 

 

socket inside the unit.

Side View of PM Card

 

GARRETT

24

Image 29
Contents Magnum 700X Mini-Concentrator Trademarks Magnum Mini-Concentrator Installation and User GuideContacting Garrett Communications Phone 510Introduction Table of ContentsMagnum  Specifications LED Indicators on Chassis Technical Specifications, ConnectorsWarranty PackagingSpecifications Bridge Port Modules BPMs Specifications Repeater Port Modules RPMsOrdering Information Magnum 700X Mini-Concentrator Product Description IntroductionInspecting the Package and Product 1 Magnum 700X Mini-Concentrator Magnum 700X ChassisRPM-BNC Magnum 700X Repeater Port Modules RPMsRPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FP RPM-AUI Magnum RPM-BNCPin Function 2 AUI Pin AssignmentsMagnum RPM-FST RPM-FST Fiber ST, Twist-lock ConnectorRPM-DTE Connector Magnum RPM-FSC RPM-SMF Single-mode Fiber RPM-FSC Fiber SC, Snap-in ConnectorJumper Across Distances Supported 3 km10 km Not usedRPM-TP Twisted Pair Proper cooling air flow, and for safety Magnum PM-FPMagnum RPM-TP PM-FPPage Magnum BPM-FST BPM-AUIBPM-FST BPM-TP Wiring STP of 150m 500 ft.. ThisModule is designed with internal Transceiver functionality. The LinkInternal Universal Power Supply with Auto-ranging Front Mounted Connectors and LEDsRPMs Repeater Port Modules for All Standard Ethernet Media Optional Bridge Port Modules BPMsIeee Standard Reference Max. Distance Taps PM Type ApplicationsConnecting Ethernet Media InstallationMedia Ieee Standard Connector PM type Locating Magnum 700X Mini-ConcentratorsConnecting Drop Cable 10BASE5 DTE Connecting ThinNet 10BASE2 BNCConnecting ThickNet 10BASE5 AUI Connecting Single-Mode Fiber Optic SMF Connecting Fiber Optic SC-type, Snap-inRemoving the PM Face Plate Connecting Twisted Pair RJ-45, Unshielded or ShieldedPower Supply Installing the PM Card Installing PM CardsConnector socket slot Align the connector Pins on the PM cardRemoving PM Cards BPM Local Bridge Functionality OperationRepeater Functionality When the packet’s source is external, it Cases where an internal packet is filtered2c and 4.2d respectively. When an Written there. This happens when a2d External Packet Filtered 12.2e Local Isolation with Bridge Port Module Powering the Magnum 700X Mini-ConcentratorPM LEDs Chassis LEDsMagnum 700X chassis unit LEDs Before Calling for Assistance TroubleshootingReturn Material Authorization RMA Procedure When Calling for AssistanceShipping and Packaging Information No Problem FoundAppendix a Warranty Information