GarrettCom manual Ordering Information Magnum 700X Mini-Concentrator

Page 9

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

1.4Ordering Information

Magnum 700X Mini-Concentrator

Magnum 700X

Base chassis with 7 slots for RPMs and BPMs, power supply

Magnum 700X-Br

Multi-Bridge chassis with one RJ-45 RPM for the common port, and 6

 

slots for BPMs and other RPMs, power supply. Includes 5 face plates.

Magnum RPM-BNC

Repeater Module with 1 BNC connector, internal termination switch

Magnum RPM-TP

Repeater Module w/ 1 shielded female RJ-45 connector + up-link

 

switch

Magnum RPM-AUI

Repeater Module with 1 AUI (DB-15 female) connector, with slide

 

lock

Magnum RPM-DTE

Repeater Module with 1 DTE (DB-15 male) connector, with lock

 

posts

Magnum RPM-FST

Repeater Module w/ mm* Fiber ST “twist” 10BASE-FL dual

 

connector

Magnum RPM-SMF

Repeater Module w/ single mode Fiber connector

Magnum RPM-FSM** Repeater Module w/ mm* Fiber SMA “screw-on” 10BASE-FL

 

connector

Magnum BPM-BNC

Local Bridge Module with 1 BNC connector

Magnum BPM-AUI

Local Bridge Module with 1 AUI connector

Magnum BPM-FST

Local Bridge Module with mm* Fiber ST connector

Magnum BPM-TP

Local Bridge Module with 1 RJ-45 connector + up-link switch

Magnum PM-FP

Face Plate - cover for unused slots

NOTE: All RPMs and BPMs have LEDs for status information. Refer to Product Description for details.

*mm = multi-mode

**This item is available by special order only.

Note: All PMs are interchangeable for use with the Magnum 3000X Stackable Concentrators and Magnum 3000 Stackable Hubs bonus ports, and the Magnum 1000 Workgroup Hubs bonus ports. The same PMs are also used in the Magnum 30X Workgroup Bridges and the Magnum 200X and 20X Two-port Repeaters.

Garrett Communications reserves the right to change specifications, performance characteristics and/or model offerings without notice.

GARRETT

4

Image 9
Contents Magnum 700X Mini-Concentrator Trademarks Magnum Mini-Concentrator Installation and User GuideContacting Garrett Communications Phone 510Introduction Table of ContentsMagnum  Specifications LED Indicators on Chassis Technical Specifications, ConnectorsWarranty PackagingSpecifications Bridge Port Modules BPMs Specifications Repeater Port Modules RPMsOrdering Information Magnum 700X Mini-Concentrator Introduction Inspecting the Package and ProductProduct Description 1 Magnum 700X Mini-Concentrator Magnum 700X ChassisMagnum 700X Repeater Port Modules RPMs RPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FPRPM-BNC RPM-AUI Magnum RPM-BNCPin Function 2 AUI Pin AssignmentsRPM-FST Fiber ST, Twist-lock Connector RPM-DTEMagnum RPM-FST Connector Magnum RPM-FSC RPM-SMF Single-mode Fiber RPM-FSC Fiber SC, Snap-in ConnectorJumper Across Distances Supported 3 km10 km Not usedRPM-TP Twisted Pair Proper cooling air flow, and for safety Magnum PM-FPMagnum RPM-TP PM-FPPage BPM-AUI BPM-FSTMagnum BPM-FST BPM-TP Wiring STP of 150m 500 ft.. ThisModule is designed with internal Transceiver functionality. The LinkInternal Universal Power Supply with Auto-ranging Front Mounted Connectors and LEDsRPMs Repeater Port Modules for All Standard Ethernet Media Optional Bridge Port Modules BPMsIeee Standard Reference Max. Distance Taps PM Type ApplicationsConnecting Ethernet Media InstallationMedia Ieee Standard Connector PM type Locating Magnum 700X Mini-ConcentratorsConnecting ThinNet 10BASE2 BNC Connecting ThickNet 10BASE5 AUIConnecting Drop Cable 10BASE5 DTE Connecting Single-Mode Fiber Optic SMF Connecting Fiber Optic SC-type, Snap-inRemoving the PM Face Plate Connecting Twisted Pair RJ-45, Unshielded or ShieldedPower Supply Installing the PM Card Installing PM CardsConnector socket slot Align the connector Pins on the PM cardRemoving PM Cards Operation Repeater FunctionalityBPM Local Bridge Functionality When the packet’s source is external, it Cases where an internal packet is filtered2c and 4.2d respectively. When an Written there. This happens when a2d External Packet Filtered 12.2e Local Isolation with Bridge Port Module Powering the Magnum 700X Mini-ConcentratorChassis LEDs Magnum 700X chassis unit LEDsPM LEDs Before Calling for Assistance TroubleshootingReturn Material Authorization RMA Procedure When Calling for AssistanceShipping and Packaging Information No Problem FoundAppendix a Warranty Information