GarrettCom Magnum 700X manual Specifications

Page 6

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

1.0SPECIFICATIONS

This chapter gives the specifications of the Magnum 700X mixed-media concentrator, as well as those of the various Port Modules (PMs).

1.1Technical Specifications

Performance

Data Rate: 10 Mbps

RPM Partitioning: Enforced after 32 consecutive collisions.

RPM Reconnect: Occurs after 512 bits error-free transmission.

BPM Auto-learning Address List: 256 node capacity.

BPM Filtering and Forwarding Rate: 14,880 pps max.

Maximum Ethernet Segment Lengths

 

 

DTE (AUI Drop Cable)

- 50 m (164 ft)

10BASE-T (twisted pair)

-

100 m (328 ft)

Shielded twisted pair

-

150m (492 ft)

10BASE2 ThinNet (BNC)

- 185 m (607 ft)

10BASE5 ThickNet

- 500 m (1,640 ft)

FOIRL multi-mode Fiber optic

-

1 km (3,281 ft)

10BASE-FL multi-mode Fiber optic

-

2 km (6,562 ft)

Single-mode Fiber optic

-

10 km (32,810 ft)

Network Standards

Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2, 10BASE-FL & FOIRL, and DTE

(The Magnum 700X Mini-Concentrator is a physical layer standard Ethernet product, and operates independently of all software.)

Operating Environment

 

Ambient Temperature:

32ºF to 122ºF (0ºC to 50ºC)

Storage Temperature:

-20ºC to 60ºC

Ambient Relative Humidity: 10% to 95% (non-condensing)

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed, rear of chassis

Input Voltage: 90 to 260 vac (auto-ranging)

Input Frequency: 47 to 63 Hz (auto-ranging)

Power Consumption: 40 watts max

GARRETT

1

Image 6
Contents Magnum 700X Mini-Concentrator Magnum Mini-Concentrator Installation and User Guide TrademarksPhone 510 Contacting Garrett CommunicationsTable of Contents IntroductionMagnum  Specifications Warranty Technical Specifications, ConnectorsLED Indicators on Chassis PackagingSpecifications Repeater Port Modules RPMs Specifications Bridge Port Modules BPMsOrdering Information Magnum 700X Mini-Concentrator Introduction Inspecting the Package and ProductProduct Description Magnum 700X Chassis 1 Magnum 700X Mini-ConcentratorMagnum 700X Repeater Port Modules RPMs RPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FPRPM-BNC Magnum RPM-BNC RPM-AUI2 AUI Pin Assignments Pin FunctionRPM-FST Fiber ST, Twist-lock Connector RPM-DTEMagnum RPM-FST Jumper Across Distances Supported RPM-FSC Fiber SC, Snap-in ConnectorConnector Magnum RPM-FSC RPM-SMF Single-mode Fiber 3 kmNot used 10 kmMagnum RPM-TP Proper cooling air flow, and for safety Magnum PM-FPRPM-TP Twisted Pair PM-FPPage BPM-AUI BPM-FSTMagnum BPM-FST Module is designed with internal Wiring STP of 150m 500 ft.. ThisBPM-TP Transceiver functionality. The LinkRPMs Repeater Port Modules for All Standard Ethernet Media Front Mounted Connectors and LEDsInternal Universal Power Supply with Auto-ranging Optional Bridge Port Modules BPMsApplications Ieee Standard Reference Max. Distance Taps PM TypeMedia Ieee Standard Connector PM type InstallationConnecting Ethernet Media Locating Magnum 700X Mini-ConcentratorsConnecting ThinNet 10BASE2 BNC Connecting ThickNet 10BASE5 AUIConnecting Drop Cable 10BASE5 DTE Connecting Fiber Optic SC-type, Snap-in Connecting Single-Mode Fiber Optic SMFConnecting Twisted Pair RJ-45, Unshielded or Shielded Removing the PM Face PlatePower Supply Connector socket slot Installing PM CardsInstalling the PM Card Align the connector Pins on the PM cardRemoving PM Cards Operation Repeater FunctionalityBPM Local Bridge Functionality 2c and 4.2d respectively. When an Cases where an internal packet is filteredWhen the packet’s source is external, it Written there. This happens when a2d External Packet Filtered Powering the Magnum 700X Mini-Concentrator 12.2e Local Isolation with Bridge Port ModuleChassis LEDs Magnum 700X chassis unit LEDsPM LEDs Troubleshooting Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationAppendix a Warranty Information