GarrettCom Magnum 700X manual Phone 510, Contacting Garrett Communications

Page 3

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

Contacting Garrett Communications

Please use the mailing address and phone and fax numbers listed below:

Garrett Communications

47823 Westinghouse Drive

Fremont, CA 94539

Phone (510) 438-9071

Fax (510) 438-9072

WWW:http://www.garrettcom.com E-mail: support@garrettcom.com

Federal Communications Commission

Radio Frequency Interference Statement

This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.

GARRETT

ii

Image 3
Contents Magnum 700X Mini-Concentrator Trademarks Magnum Mini-Concentrator Installation and User GuideContacting Garrett Communications Phone 510Introduction Table of ContentsMagnum  Specifications Packaging Technical Specifications, ConnectorsLED Indicators on Chassis WarrantySpecifications Bridge Port Modules BPMs Specifications Repeater Port Modules RPMsOrdering Information Magnum 700X Mini-Concentrator Introduction Inspecting the Package and ProductProduct Description 1 Magnum 700X Mini-Concentrator Magnum 700X ChassisMagnum 700X Repeater Port Modules RPMs RPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FPRPM-BNC RPM-AUI Magnum RPM-BNCPin Function 2 AUI Pin AssignmentsRPM-FST Fiber ST, Twist-lock Connector RPM-DTEMagnum RPM-FST 3 km RPM-FSC Fiber SC, Snap-in ConnectorConnector Magnum RPM-FSC RPM-SMF Single-mode Fiber Jumper Across Distances Supported10 km Not usedPM-FP Proper cooling air flow, and for safety Magnum PM-FPRPM-TP Twisted Pair Magnum RPM-TPPage BPM-AUI BPM-FSTMagnum BPM-FST Transceiver functionality. The Link Wiring STP of 150m 500 ft.. ThisBPM-TP Module is designed with internalOptional Bridge Port Modules BPMs Front Mounted Connectors and LEDsInternal Universal Power Supply with Auto-ranging RPMs Repeater Port Modules for All Standard Ethernet MediaIeee Standard Reference Max. Distance Taps PM Type ApplicationsLocating Magnum 700X Mini-Concentrators InstallationConnecting Ethernet Media Media Ieee Standard Connector PM typeConnecting ThinNet 10BASE2 BNC Connecting ThickNet 10BASE5 AUIConnecting Drop Cable 10BASE5 DTE Connecting Single-Mode Fiber Optic SMF Connecting Fiber Optic SC-type, Snap-inRemoving the PM Face Plate Connecting Twisted Pair RJ-45, Unshielded or ShieldedPower Supply Align the connector Pins on the PM card Installing PM CardsInstalling the PM Card Connector socket slotRemoving PM Cards Operation Repeater FunctionalityBPM Local Bridge Functionality Written there. This happens when a Cases where an internal packet is filteredWhen the packet’s source is external, it 2c and 4.2d respectively. When an2d External Packet Filtered 12.2e Local Isolation with Bridge Port Module Powering the Magnum 700X Mini-ConcentratorChassis LEDs Magnum 700X chassis unit LEDsPM LEDs Before Calling for Assistance TroubleshootingReturn Material Authorization RMA Procedure When Calling for AssistanceShipping and Packaging Information No Problem FoundAppendix a Warranty Information