1.0 SPECIFICATIONS

1

1.1

Technical Specifications

1

1.2,3 Specifications - Port Modules (RPMs and BPMs)

3

1.4

Ordering Information

4

2.0 INTRODUCTION

..........................................................................................

5

2.1

Inspecting the Package and Product

5

2.2

Product Description

5

2.2.1 Magnum 700X and 700X-Br ** Chassis

6

2.3 Magnum 700X - Repeater Port Modules (RPMs)

7

2.3.1 RPM-BNC

...................................................................................................

7

2.3.2 RPM-AUI

8

2.3.3 RPM-DTE

.................................................................................................

10

2.3.4 RPM-FST

(Fiber ST, Twist-lock Connector)

10

2.3.5 RPM-FSC

(Fiber SC, Snap-in Connector)

11

2.3.6 RPM-SMF (Single Mode Fiber)

11

2.3.7 RPM-TP

(Twisted Pair)

13

2.3.8 PM-FP

13

2.4 Magnum 700X and 700X-Br ** - Bridge Port Modules (BPMs)

14

2.4.1 BPM-BNC

.................................................................................................

14

2.4.2 BPM-AUI

15

2.4.3 BPM-FST

15

2.4.4 BPM-TP

16

2.5

Features and Benefits

17

2.6

Applications

18

3.0 INSTALLATION

19

3.1

Locating Magnum 700X Mini-Concentrators

19

3.2

Connecting Ethernet Media

19

3.2.1 Connecting ThinNet 10BASE2 (BNC)

20

3.2.2,3 Connecting ThickNet 10BASE5 (AUI and DTE)

20

3.2.4,5,6 Connecting Fiber Optic (3 types)

20,21

3.2.7 Connecting Twisted Pair (RJ-45, Unshielded or Shielded)

22

3.3

Removing the PM Face Plate

22

3.4

Installing PM Cards

24

3.5

Removing PM Cards

25

4.0 OPERATION

26

4.1

Repeater Functionality

26

4.2

BPM Local Bridge Functionality **

26

4.3

Powering the Magnum 700X Mini-Concentrator

29

4.4,5 Chassis LEDs, PM LEDs

30

5.0 TROUBLESHOOTING

31

5.1

Before Calling for Assistance

31

5.2

When Calling for Assistance

32

5.3

Return Material Authorization (RMA) Procedure

32

5.4

Shipping and Packaging Information

33

APPENDIX A: WARRANTY INFORMATION

34

 

** CHANGES MADE IN THIS REVISION

 

GARRETT

iii

Image 4
Contents Magnum 700X Mini-Concentrator Magnum Mini-Concentrator Installation and User Guide TrademarksPhone 510 Contacting Garrett CommunicationsTable of Contents IntroductionMagnum  Specifications Technical Specifications, Connectors LED Indicators on ChassisWarranty PackagingSpecifications Repeater Port Modules RPMs Specifications Bridge Port Modules BPMsOrdering Information Magnum 700X Mini-Concentrator Inspecting the Package and Product IntroductionProduct Description Magnum 700X Chassis 1 Magnum 700X Mini-ConcentratorRPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FP Magnum 700X Repeater Port Modules RPMsRPM-BNC Magnum RPM-BNC RPM-AUI2 AUI Pin Assignments Pin FunctionRPM-DTE RPM-FST Fiber ST, Twist-lock ConnectorMagnum RPM-FST RPM-FSC Fiber SC, Snap-in Connector Connector Magnum RPM-FSC RPM-SMF Single-mode FiberJumper Across Distances Supported 3 kmNot used 10 kmProper cooling air flow, and for safety Magnum PM-FP RPM-TP Twisted PairMagnum RPM-TP PM-FPPage BPM-FST BPM-AUIMagnum BPM-FST Wiring STP of 150m 500 ft.. This BPM-TPModule is designed with internal Transceiver functionality. The LinkFront Mounted Connectors and LEDs Internal Universal Power Supply with Auto-rangingRPMs Repeater Port Modules for All Standard Ethernet Media Optional Bridge Port Modules BPMsApplications Ieee Standard Reference Max. Distance Taps PM TypeInstallation Connecting Ethernet MediaMedia Ieee Standard Connector PM type Locating Magnum 700X Mini-ConcentratorsConnecting ThickNet 10BASE5 AUI Connecting ThinNet 10BASE2 BNCConnecting Drop Cable 10BASE5 DTE Connecting Fiber Optic SC-type, Snap-in Connecting Single-Mode Fiber Optic SMFConnecting Twisted Pair RJ-45, Unshielded or Shielded Removing the PM Face PlatePower Supply Installing PM Cards Installing the PM CardConnector socket slot Align the connector Pins on the PM cardRemoving PM Cards Repeater Functionality OperationBPM Local Bridge Functionality Cases where an internal packet is filtered When the packet’s source is external, it2c and 4.2d respectively. When an Written there. This happens when a2d External Packet Filtered Powering the Magnum 700X Mini-Concentrator 12.2e Local Isolation with Bridge Port ModuleMagnum 700X chassis unit LEDs Chassis LEDsPM LEDs Troubleshooting Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationAppendix a Warranty Information