GarrettCom Magnum 700X manual Not used, 10 km

Page 17

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

Note: Be sure to use single-mode fiber optic cable with this module. Single-mode fiber has a smaller diameter than multi-mode fiber (2/15 - 8/60 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode, where xx/xx are the diameters of the core and the core plus the cladding respectively).

NOTE: The RPM-SMF circuit board contains a six pin jumpers, but the jumper is only to be placed across pins 5 & 6. (Chg. 11/98) Others are not used.

JUMPER ACROSS

DISTANCES SUPPORTED

1 - 2

not used

3 - 4

not used

5 - 6

0 - 10 km

 

1 2

 

3 4

DEFAULT

5 6

 

 

J1

GARRETT

12

Image 17
Contents Magnum 700X Mini-Concentrator Trademarks Magnum Mini-Concentrator Installation and User GuideContacting Garrett Communications Phone 510Introduction Table of ContentsMagnum  Specifications LED Indicators on Chassis Technical Specifications, ConnectorsWarranty PackagingSpecifications Bridge Port Modules BPMs Specifications Repeater Port Modules RPMsOrdering Information Magnum 700X Mini-Concentrator Product Description IntroductionInspecting the Package and Product 1 Magnum 700X Mini-Concentrator Magnum 700X ChassisRPM-BNC Magnum 700X Repeater Port Modules RPMsRPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FP RPM-AUI Magnum RPM-BNC Pin Function 2 AUI Pin AssignmentsMagnum RPM-FST RPM-FST Fiber ST, Twist-lock ConnectorRPM-DTE Connector Magnum RPM-FSC RPM-SMF Single-mode Fiber RPM-FSC Fiber SC, Snap-in ConnectorJumper Across Distances Supported 3 km10 km Not usedRPM-TP Twisted Pair Proper cooling air flow, and for safety Magnum PM-FPMagnum RPM-TP PM-FPPage Magnum BPM-FST BPM-AUIBPM-FST BPM-TP Wiring STP of 150m 500 ft.. ThisModule is designed with internal Transceiver functionality. The LinkInternal Universal Power Supply with Auto-ranging Front Mounted Connectors and LEDsRPMs Repeater Port Modules for All Standard Ethernet Media Optional Bridge Port Modules BPMsIeee Standard Reference Max. Distance Taps PM Type ApplicationsConnecting Ethernet Media InstallationMedia Ieee Standard Connector PM type Locating Magnum 700X Mini-ConcentratorsConnecting Drop Cable 10BASE5 DTE Connecting ThinNet 10BASE2 BNCConnecting ThickNet 10BASE5 AUI Connecting Single-Mode Fiber Optic SMF Connecting Fiber Optic SC-type, Snap-inRemoving the PM Face Plate Connecting Twisted Pair RJ-45, Unshielded or ShieldedPower Supply Installing the PM Card Installing PM CardsConnector socket slot Align the connector Pins on the PM cardRemoving PM Cards BPM Local Bridge Functionality OperationRepeater Functionality When the packet’s source is external, it Cases where an internal packet is filtered2c and 4.2d respectively. When an Written there. This happens when a2d External Packet Filtered 12.2e Local Isolation with Bridge Port Module Powering the Magnum 700X Mini-ConcentratorPM LEDs Chassis LEDsMagnum 700X chassis unit LEDs Before Calling for Assistance TroubleshootingReturn Material Authorization RMA Procedure When Calling for AssistanceShipping and Packaging Information No Problem FoundAppendix a Warranty Information