1.2Specifications - Repeater Port Modules (RPMs)

RPM Type :

BNC

AUI

DTE

Fiber-mm Fiber-sgl.m

TP*

Front Access

yes

yes

yes

yes

yes

yes

Connector Type

BNC-f

DB-15 f

DB-15 m

ST or SC

Fiber-ST

RJ-45

Partition (PART)LED

yes

yes

yes

yes

yes

yes

Receive (RX) LED

yes

yes

yes

yes

yes

yes

LINK LED

n.a.

n.a.

n.a.

yes

yes

yes

Switch on Face Plate

yes**

n.a.

n.a.

n.a.

n.a.

yes***

“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to 2.0Km. “Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.

*The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

**Internal termination switch for BNC, no "T" connector is required.

***MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link,

no crossover cable is required.

1.3Specifications - Bridge Port Modules (BPMs)

BPM Type :

BNC

AUI

Fiber

TP*

Connector Type

BNC(f)

DB-15(f)

ST

RJ-45

Switch on FP

yes**

n.a.

n.a.

yes***

FWD-I LED

yes

yes

yes

yes

FWD-X LED

yes

yes

yes

yes

LINK LED

n.a.

n.a.

yes

yes

*The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

**Internal termination switch for BNC, no "T" connector is required.

***MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link,

no crossover cable is required.

NOTE: As of May, 1998, multiple BPMs (up to six) may be installed in a 700X chassis to provide parallel bridging for the BPM’s attached segments. This will increase network performance in applications where there is significant local traffic on the bridged segments. (see Section 4.2) Any mix of RPM and BPM types may be configured together in a 700X, with a maximum of 6 BPMs and 7 total PMs per unit..

GARRETT

3

Image 8
Contents Magnum 700X Mini-Concentrator Magnum Mini-Concentrator Installation and User Guide TrademarksPhone 510 Contacting Garrett CommunicationsTable of Contents Introduction Magnum  Specifications Technical Specifications, Connectors LED Indicators on ChassisWarranty PackagingSpecifications Repeater Port Modules RPMs Specifications Bridge Port Modules BPMsOrdering Information Magnum 700X Mini-Concentrator Product Description IntroductionInspecting the Package and Product Magnum 700X Chassis 1 Magnum 700X Mini-ConcentratorRPM-BNC Magnum 700X Repeater Port Modules RPMsRPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FP Magnum RPM-BNC RPM-AUI2 AUI Pin Assignments Pin FunctionMagnum RPM-FST RPM-FST Fiber ST, Twist-lock ConnectorRPM-DTE RPM-FSC Fiber SC, Snap-in Connector Connector Magnum RPM-FSC RPM-SMF Single-mode FiberJumper Across Distances Supported 3 kmNot used 10 kmProper cooling air flow, and for safety Magnum PM-FP RPM-TP Twisted PairMagnum RPM-TP PM-FPPage Magnum BPM-FST BPM-AUIBPM-FST Wiring STP of 150m 500 ft.. This BPM-TPModule is designed with internal Transceiver functionality. The LinkFront Mounted Connectors and LEDs Internal Universal Power Supply with Auto-rangingRPMs Repeater Port Modules for All Standard Ethernet Media Optional Bridge Port Modules BPMsApplications Ieee Standard Reference Max. Distance Taps PM TypeInstallation Connecting Ethernet MediaMedia Ieee Standard Connector PM type Locating Magnum 700X Mini-ConcentratorsConnecting Drop Cable 10BASE5 DTE Connecting ThinNet 10BASE2 BNCConnecting ThickNet 10BASE5 AUI Connecting Fiber Optic SC-type, Snap-in Connecting Single-Mode Fiber Optic SMFConnecting Twisted Pair RJ-45, Unshielded or Shielded Removing the PM Face PlatePower Supply Installing PM Cards Installing the PM CardConnector socket slot Align the connector Pins on the PM cardRemoving PM Cards BPM Local Bridge Functionality OperationRepeater Functionality Cases where an internal packet is filtered When the packet’s source is external, it2c and 4.2d respectively. When an Written there. This happens when a2d External Packet Filtered Powering the Magnum 700X Mini-Concentrator 12.2e Local Isolation with Bridge Port ModulePM LEDs Chassis LEDsMagnum 700X chassis unit LEDs Troubleshooting Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationAppendix a Warranty Information